Refine
Has Fulltext
- yes (45)
Is part of the Bibliography
- yes (45)
Year of publication
Document Type
- Journal article (38)
- Preprint (4)
- Conference Proceeding (3)
Language
- English (45)
Keywords
- PET (15)
- Positronen-Emissions-Tomografie (10)
- theranostics (10)
- CXCR4 (8)
- neuroendocrine tumor (8)
- PET/CT (7)
- PRRT (6)
- molecular imaging (6)
- multiple myeloma (6)
- PSMA (5)
- positron emission tomography (5)
- prostate cancer (5)
- RADS (4)
- SPECT (4)
- SSTR (4)
- somatostatin receptor (4)
- 18F-DCFPyL (3)
- DaTscan (3)
- FDG (3)
- NET (3)
- Prostate Cancer (3)
- medicine (3)
- peptide receptor radionuclide therapy (3)
- radioligand therapy (3)
- 18F-FDG (2)
- 18F-FDG PET/CT (2)
- Ioflupane (2)
- MAG3 (2)
- PSMA-PET (2)
- PSMA-RADS (2)
- Parkinson (2)
- Parkinson Disease (2)
- Parkinson-Krankheit (2)
- Positron Emission Tomography (2)
- SSTR-RADS (2)
- TKI (2)
- Virchow Node (2)
- [177Lu]-DOTATATE/-DOTATOC (2)
- [68Ga] (2)
- chemokine receptor (2)
- fibroblast activation protein (2)
- personalized medicine (2)
- prostate-specific membrane antigen (2)
- prostate-specific membrane antigen (PSMA) (2)
- reporting and data system (2)
- tumor heterogeneity (2)
- vandetanib (2)
- 11C-Methionine PET/CT (1)
- 123I-Ioflupane (1)
- 177Lu (1)
- 18F-DCFPL (1)
- 2-deoxy-2-(18F)fluoro-D-glucose (1)
- 68Ga-DOTANOC (1)
- 68Ga-DOTATATE (1)
- 68Ga-DOTATOC (1)
- 68Ga-Pentixafor PET/CT (1)
- <sup>18</sup>F-FDG (1)
- <sup>68</sup>Ga-Pentixafor (1)
- Arginine (1)
- C-X-C motif chemokine receptor 4 (1)
- DOTA-EB-TATE (1)
- DOTATOC (1)
- Ganglia (1)
- HMDP hydroxymethylene diphosphonate (1)
- Hyperkalaemia (1)
- Imaging pitfalls (1)
- Lysine (1)
- MI-RADS (1)
- MRI (1)
- Merkel cell carcinoma (1)
- Molecular imaging (1)
- Myocardial-perfusion SPECT (1)
- NEC (1)
- PROMISE (1)
- Pancreas (1)
- Parkinsonism (1)
- Parkinson’s disease (1)
- Pentixafor (1)
- Pitfall (1)
- Positron emission tomography (1)
- Prostata (1)
- Radiofluorine (1)
- Radiotracer (1)
- SPECT/CT (1)
- SSTR-PET (1)
- SUV (1)
- Single-Photon-Emissions-Computertomographie (1)
- Somatostatin receptor expression (1)
- Tracer (1)
- [177Lu]/[90Y]PentixaTher (1)
- [68Ga]DOTATOC (1)
- [68Ga]PentixaFor (1)
- [68Ga]Pentixafor (1)
- [\(^{68}\)Ga] pentixafor (1)
- [\(^{68}\)Ga]Ga-FAPI (1)
- [\(^{68}\)Ga]Pentixafor (1)
- \(^{11}\)C-Methionine-PET (1)
- \(^{11}\)C-methionine (1)
- \(^{18}\)F (1)
- \(^{18}\)F-FDG PET/CT (1)
- \(^{68}\)Ga (1)
- \(^{68}\)Ga-Pentixafor (1)
- ageing (1)
- agreement (1)
- amino acids (1)
- biokinetics (1)
- biomarker (1)
- bone disease (1)
- chemokine receptor-4 (1)
- comparability (1)
- ejection fraction (1)
- endoradiotherapy (1)
- esophagogastric junction (1)
- evans blue (1)
- experience (1)
- glioblastoma (1)
- glioblastoma multiforme (1)
- glioma (1)
- head and neck cancer (1)
- hyperkalemia (1)
- imaging (1)
- imaging techniques (1)
- immunostaining (1)
- interobserver (1)
- interreader (1)
- intraindividual comparison (1)
- kidney function (1)
- left-ventricular function (1)
- macrophages (1)
- magnetic resonance imaging (1)
- management (1)
- medullary thyroid carcinoma (1)
- metabolic tumor volume (MTV) (1)
- metabolic tumour volume (MTV) (1)
- methionine (1)
- microglial cells (1)
- mouse (1)
- neuroendocrine neoplasia (1)
- ollimator (1)
- pancreas (1)
- pattern (1)
- pleural mesothelioma (1)
- positron emission tomography/computed tomography (1)
- post-reconstruction filtering (1)
- progression (1)
- quality (1)
- quantification (1)
- radiogenomics (1)
- radionuclide therapy (1)
- relapse (1)
- renal scintigraphy (1)
- reporting and data systems (1)
- scanner (1)
- skeletal (1)
- small animal SPECT (1)
- small-animal imaging (1)
- smoldering myeloma (1)
- software (1)
- solid tumors (1)
- somatostatin (1)
- somatostatin receptor (SSTR) (1)
- standardization (1)
- standardized reporting (1)
- stem-cell transplantation (1)
- total lesion PSMA (1)
- total lesion glycolysis (TLG) (1)
- total lesion methionine uptake (TLMU) (1)
- treatment response (1)
- tyrosine kinase inhibitor (1)
- vestibular schwannoma (1)
Institute
- Klinik und Poliklinik für Nuklearmedizin (45) (remove)
Sonstige beteiligte Institutionen
EU-Project number / Contract (GA) number
- 701983 (16)
Purpose
While [\(^{18}\)F]-fluorodeoxyglucose ([\(^{18}\)F]FDG) is the standard for positron emission tomography/computed tomography (PET/CT) imaging of oral squamous cell carcinoma (OSCC), diagnostic specificity is hampered by uptake in inflammatory cells such as neutrophils or macrophages. Recently, molecular imaging probes targeting fibroblast activation protein α (FAP), which is overexpressed in a variety of cancer-associated fibroblasts, have become available and might constitute a feasible alternative to FDG PET/CT.
Methods
Ten consecutive, treatment-naïve patients (8 males, 2 females; mean age, 62 ± 9 years) with biopsy-proven OSCC underwent both whole-body [\(^{18}\)F]FDG and [\(^{68}\)Ga]FAPI-04 (FAP-directed) PET/CT for primary staging prior to tumor resection and cervical lymph node dissection. Detection of the primary tumor, as well as the presence and number of lymph node and distant metastases was analysed. Intensity of tracer accumulation was assessed by means of maximum (SUV\(_{max}\)) and peak (SUV\(_{peak}\) standardized uptake values. Histological work-up including immunohistochemical staining for FAP served as standard of reference.
Results
[\(^{18}\)F]FDG and FAP-directed PET/CT detected all primary tumors with a SUVmax of 25.5 ± 13.2 (FDG) and 20.5 ± 6.4 (FAP-directed) and a SUVpeak of 16.1 ± 10.3 ([\(^{18}\)F]FDG) and 13.8 ± 3.9 (FAP-directed), respectively. Regarding cervical lymph node metastases, FAP-directed PET/CT demonstrated comparable sensitivity (81.3% vs. 87.5%; P = 0.32) and specificity (93.3% vs. 81.3%; P = 0.16) to [\(^{18}\)F]FDG PET/CT. FAP expression on the cell surface of cancer-associated fibroblasts in both primary lesions as well as lymph nodes metastases was confirmed in all samples.
Conclusion
FAP-directed PET/CT in OSCC seems feasible. Future research to investigate its potential to improve patient staging is highly warranted.
(1) Background: We aimed to quantitatively investigate [\(^{68}\)Ga]Ga-FAPI-04 uptake in normal organs and to assess a relationship with the extent of FAPI-avid tumor burden. (2) Methods: In this single-center retrospective analysis, thirty-four patients with solid cancers underwent a total of 40 [\(^{68}\)Ga]Ga-FAPI-04 PET/CT scans. Mean standardized uptake values (SUV\(_{mean}\)) for normal organs were established by placing volumes of interest (VOIs) in the heart, liver, spleen, pancreas, kidneys, and bone marrow. Total tumor burden was determined by manual segmentation of tumor lesions with increased uptake. For tumor burden, quantitative assessment included maximum SUV (SUV\(_{max}\)), tumor volume (TV), and fractional tumor activity (FTA = TV × SUV\(_{mean}\)). Associations between uptake in normal organs and tumor burden were investigated by applying Spearman's rank correlation coefficient. (3) Results: Median SUV\(_{mean}\) values were 2.15 in the pancreas (range, 1.05–9.91), 1.42 in the right (range, 0.57–3.06) and 1.41 in the left kidney (range, 0.73–2.97), 1.2 in the heart (range, 0.46–2.59), 0.86 in the spleen (range, 0.55–1.58), 0.65 in the liver (range, 0.31–2.11), and 0.57 in the bone marrow (range, 0.26–0.94). We observed a trend towards significance for uptake in the myocardium and tumor-derived SUV\(_{max}\) (ρ = 0.29, p = 0.07) and TV (ρ = −0.30, p = 0.06). No significant correlation was achieved for any of the other organs: SUV\(_{max}\) (ρ ≤ 0.1, p ≥ 0.42), TV (ρ ≤ 0.11, p ≥ 0.43), and FTA (ρ ≤ 0.14, p ≥ 0.38). In a sub-analysis exclusively investigating patients with high tumor burden, significant correlations of myocardial uptake with tumor SUV\(_{max}\) (ρ = 0.44; p = 0.03) and tumor-derived FTA with liver uptake (ρ = 0.47; p = 0.02) were recorded. (4) Conclusions: In this proof-of-concept study, quantification of [\(^{68}\)Ga]Ga-FAPI-04 PET showed no significant correlation between normal organs and tumor burden, except for a trend in the myocardium. Those preliminary findings may trigger future studies to determine possible implications for treatment with radioactive FAP-targeted drugs, as higher tumor load or uptake may not lead to decreased doses in the majority of normal organs.
Background
CXCR4-directed positron emission tomography/computed tomography (PET/CT) has been used as a diagnostic tool in patients with solid tumors. We aimed to determine a potential correlation between tumor burden and radiotracer accumulation in normal organs.
Methods
Ninety patients with histologically proven solid cancers underwent CXCR4-targeted [\(^{68}\)Ga]Ga-PentixaFor PET/CT. Volumes of interest (VOIs) were placed in normal organs (heart, liver, spleen, bone marrow, and kidneys) and tumor lesions. Mean standardized uptake values (SUV\(_{mean}\)) for normal organs were determined. For CXCR4-positive tumor burden, maximum SUV (SUV\(_{max}\)), tumor volume (TV), and fractional tumor activity (FTA, defined as SUV\(_{mean}\) x TV), were calculated. We used a Spearman's rank correlation coefficient (ρ) to derive correlative indices between normal organ uptake and tumor burden.
Results
Median SUV\(_{mean}\) in unaffected organs was 5.2 for the spleen (range, 2.44 – 10.55), 3.27 for the kidneys (range, 1.52 – 17.4), followed by bone marrow (1.76, range, 0.84 – 3.98), heart (1.66, range, 0.88 – 2.89), and liver (1.28, range, 0.73 – 2.45). No significant correlation between SUV\(_{max}\) in tumor lesions (ρ ≤ 0.189, P ≥ 0.07), TV (ρ ≥ -0.204, P ≥ 0.06) or FTA (ρ ≥ -0.142, P ≥ 0.18) with the investigated organs was found.
Conclusions
In patients with solid tumors imaged with [\(^{68}\)Ga]Ga-PentixaFor PET/CT, no relevant tumor sink effect was noted. This observation may be of relevance for therapies with radioactive and non-radioactive CXCR4-directed drugs, as with increasing tumor burden, the dose to normal organs may remain unchanged.
Purpose
For somatostatin receptor (SSTR)-positron emission tomography/computed tomography (PET/CT), a standardized framework termed SSTR-reporting and data system (RADS) has been proposed. We aimed to elucidate the impact of a RADS-focused training on reader’s anxiety to report on SSTR-PET/CT, the motivational beliefs in learning such a system, whether it increases reader’s confidence, and its implementation in clinical routine.
Procedures
A 3-day training course focusing on SSTR-RADS was conducted. Self-report questionnaires were handed out prior to the course (Pre) and thereafter (Post). The impact of the training on the following categories was evaluated: (1) test anxiety to report on SSTR-PET/CT, (2) motivational beliefs, (3) increase in reader’s confidence, and (4) clinical implementation. To assess the effect size of the course, Cohen’s d was calculated (small, d = 0.20; large effect, d = 0.80).
Results
Of 22 participants, Pre and Post were returned by 21/22 (95.5%). In total, 14/21 (66.7%) were considered inexperienced (IR, < 1 year experience in reading SSTR-PET/CTs) and 7/21 (33.3%) as experienced readers (ER, > 1 year). Applying SSTR-RADS, a large decrease in anxiety to report on SSTR-PET/CT was noted for IR (d = − 0.74, P = 0.02), but not for ER (d = 0.11, P = 0.78). For the other three categories motivational beliefs, reader’s confidence, and clinical implementation, agreement rates were already high prior to the training and persisted throughout the course (P ≥ 0.21).
Conclusions
A framework-focused reader training can reduce anxiety to report on SSTR-PET/CTs, in particular for inexperienced readers. This may allow for a more widespread adoption of this system, e.g., in multicenter trials for better intra- and interindividual comparison of scan results.