Refine
Has Fulltext
- yes (3) (remove)
Is part of the Bibliography
- yes (3)
Year of publication
- 2014 (3) (remove)
Document Type
- Journal article (3)
Language
- English (3)
Keywords
- Chirurgie (1)
- Germany (1)
- HUWE1 (1)
- Hesse (1)
- MIZ1 (1)
- MYC (1)
- cancer (1)
- colorectal cancer (1)
- digestive system (1)
- drug discovery (1)
Institute
- Theodor-Boveri-Institut für Biowissenschaften (2)
- Deutsches Zentrum für Herzinsuffizienz (DZHI) (1)
- Frauenklinik und Poliklinik (1)
- Institut für Anatomie und Zellbiologie (1)
- Institut für Klinische Epidemiologie und Biometrie (1)
- Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I) (1)
Sonstige beteiligte Institutionen
EU-Project number / Contract (GA) number
- 223153 (1)
Clinical prognosis of metastasized colorectal carcinoma (CRC) is still not at desired levels and novel drugs are needed. Here, we focused on the multi-tyrosine kinase inhibitor E7080 (Lenvatinib) and assessed its therapeutic efficacy against human CRC cell lines in vitro and human CRC xenografts in vivo. The effect of E7080 on cell viability was examined on 10 humanCRCcell lines and humanendothelial cells (HUVEC). The inhibitory effect of E7080 on VEGF-induced angiogenesis was studied in an ex vivo mouse aortic ring angiogenesis assay. In addition, the efficacy of E7080 against xenografts derived fromCRC cell lines and CRC patient resection specimenswithmutated KRASwas investigated in vivo. Arelatively low cytotoxic effect of E7080 on CRC cell viabilitywas observed in vitro. Endothelial cells (HUVEC)weremore susceptible to the incubation with E7080. This is in line with the observation that E7080 demonstrated an anti-angiogenic effect in a three-dimensional ex vivo mouse aortic ring angiogenesis assay. E7080 effectively disrupted CRC cell-mediated VEGF-stimulated growth of HUVEC in vitro. Daily in vivo treatment with E7080 (5 mg/kg) significantly delayed the growth of KRAS mutated CRC xenografts with decreased density of tumor-associated vessel formations and without tumor regression. This observation is in line with results that E7080 did not significantly reduce the number of Ki67-positive cells in CRC xenografts. The results suggest antiangiogenic activity of E7080 at a dosage thatwas well tolerated by nudemice. E7080 may provide therapeutic benefits in the treatment of CRC with mutated KRAS.
Deregulated expression of MYC is a driver of colorectal carcinogenesis, necessitating novel strategies to inhibit MYC function. The ubiquitin ligase HUWE1 (HECTH9, ARF-BP1, MULE) associates with both MYC and the MYC-associated protein MIZ1. We show here that HUWE1 is required for growth of colorectal cancer cells in culture and in orthotopic xenograft models. Using high-throughput screening, we identify small molecule inhibitors of HUWE1, which inhibit MYC-dependent transactivation in colorectal cancer cells, but not in stem and normal colon epithelial cells. Inhibition of HUWE1 stabilizes MIZ1. MIZ1 globally accumulates on MYC target genes and contributes to repression of MYC-activated target genes upon HUWE1 inhibition. Our data show that transcriptional activation by MYC in colon cancer cells requires the continuous degradation of MIZ1 and identify a novel principle that allows for inhibition of MYC function in tumor cells.
The Quality of Acute Stroke Care-an Analysis of Evidence-Based Indicators in 260 000 Patients
(2014)
Background: Stroke patients should be cared for in accordance with evidence-based guidelines. The extent of implementation of guidelines for the acute care of stroke patients in Germany has been unclear to date. Methods: The regional quality assurance projects that cooperate in the framework of the German Stroke Registers Study Group (Arbeitsgemeinschaft Deutscher Schlaganfall-Register, ADSR) collected data on the care of stroke patients in 627 hospitals in 2012. The quality of the acute hospital care of patients with stroke or transient ischemic attack (TIA) was assessed on the basis of 15 standardized, evidence-based quality indicators and compared across the nine participating regional quality assurance projects. Results: Data were obtained on more than 260 000 patients nationwide. Intravenous thrombolysis was performed in 59.7% of eligible ischemic stroke patients patients (range among participating projects, 49.7-63.6%). Dysphagia screening was documented in 86.2% (range, 74.8-93.1%). For the following indicators, the defined targets were not reached for all of Germany: antiaggregation within 48 hours, 93.4% (range, 86.6-96.4%); anticoagulation for atrial fibrillation, 77.6% (range, 72.4-80.1%); standardized dysphagia screening, 86.2% (range, 74.8-93.1%); oral and written information of the patients or their relatives, 86.1% (range, 75.4-91.5%). The rate of patients examined or treated by a speech therapist was in the target range. Conclusion: The defined targets were reached for most of the quality indicators. Some indicators, however, varied widely across regional quality assurance projects. This implies that the standardization of care for stroke patients in Germany has not yet been fully achieved.