Refine
Has Fulltext
- yes (3)
Is part of the Bibliography
- yes (3)
Document Type
- Journal article (2)
- Doctoral Thesis (1)
Keywords
- Harris-Galante-Pfannen (1)
- Hüftgelenkprothese (1)
- Keramikkopf (1)
- Patientenaktivität (1)
- Polyethylenabrieb (1)
- Total Hip Arthroplasty (1)
- Tribologie (1)
- ZNF365 (1)
- aggregation (1)
- alumina (1)
Institute
Sonstige beteiligte Institutionen
EU-Project number / Contract (GA) number
- 223175 (1)
Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304\(\pm\)0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of \(\pm\)0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies.
BRCA1-associated breast and ovarian cancer risks can be modified by common genetic variants. To identify further cancer risk-modifying loci, we performed a multi-stage GWAS of 11,705 BRCA1 carriers (of whom 5,920 were diagnosed with breast and 1,839 were diagnosed with ovarian cancer), with a further replication in an additional sample of 2,646 BRCA1 carriers. We identified a novel breast cancer risk modifier locus at 1q32 for BRCA1 carriers (rs2290854, P = 2.7 x 10(-8), HR = 1.14, 95% CI: 1.09-1.20). In addition, we identified two novel ovarian cancer risk modifier loci: 17q21.31 (rs17631303, P = 1.4 x 10(-8), HR = 1.27, 95% CI: 1.17-1.38) and 4q32.3 (rs4691139, P = 3.4 x 10(-8), HR = 1.20, 95% CI: 1.17-1.38). The 4q32.3 locus was not associated with ovarian cancer risk in the general population or BRCA2 carriers, suggesting a BRCA1-specific association. The 17q21.31 locus was also associated with ovarian cancer risk in 8,211 BRCA2 carriers (P = 2 x 10(-4)). These loci may lead to an improved understanding of the etiology of breast and ovarian tumors in BRCA1 carriers. Based on the joint distribution of the known BRCA1 breast cancer risk-modifying loci, we estimated that the breast cancer lifetime risks for the 5% of BRCA1 carriers at lowest risk are 28%-50% compared to 81%-100% for the 5% at highest risk. Similarly, based on the known ovarian cancer risk-modifying loci, the 5% of BRCA1 carriers at lowest risk have an estimated lifetime risk of developing ovarian cancer of 28% or lower, whereas the 5% at highest risk will have a risk of 63% or higher. Such differences in risk may have important implications for risk prediction and clinical management for BRCA1 carriers.
Die durch Polyethylenabrieb bedingte Osteolyse trägt wesentlich zur Lockerung der Hüftgelenkendoprothese bei. Das Ziel der vorliegenden retrospektiven Studie war, den Einfluß der Patientenaktivität auf den Polyethylenabrieb zu bestimmen.
Es wurden 104 gut funktionierende primär implantierte Hüftgelenkprothesen [HG®-Pfanne, konventionelles PE, 28 mm Keramikköpfe] mittels Abriebmessungen [HipAnalysisSuite®Version 8.0.4.3] an 1203 Röntgenaufnahmen über durchschnittlich 12 Jahre untersucht.
Die Aktivität der durchschnittlich 58-jährigen Patienten wurde mit speziellen Fragebögen und einem Accelerometer bestimmt. Die Hochrechnung auf ein Jahr ergab 1,8 Millionen Lastwechsel im Durchschnitt und durchschnittlich 17 Stunden Aktivität pro Tag. Dabei zeigten die Messinstrumente HHS, Aktivitätseinschätzung
durch den Arzt, Gehstrecke, UCLA und TWB ansteigende Korrelationen zu den durchschnittlichen absoluten Lastwechseln pro Tag. Es zeigte sich eine durchschnittliche jährliche lineare Abriebrate von 0,1 mm, die zu 18 % von der Aktivität beeinflußt wurde und eine jährliche volumetrische Abriebrate von durchschnittlich 53 mm³, die zu 19 % von den durchgeführten Lastwechseln beeinflußt wurde. Klinische Faktoren wie Gewicht, Geschlecht, Alter bei Operation
oder Pfannenposition zeigten dagegen keine Korrelation zur
Abriebrate. Für die durchschnittlichen Lastwechsel im mittleren Aktivitätsniveau und die absoluten Lastwechsel in Kombination mit dem PeakActivityIndex ermittelte sich eine Prädiktion für das Risiko einer jährlichen linearen Abriebrate von mehr als 0,15 mm von 78%.
Diese Langzeitstudie etabliert eine direkte Korrelation zwischen der Patientenaktivität und dem Polyethylenabrieb und die untersuchte Gleitpaarung zeigte gute Langzeitergebnisse bei durchschnittlicher Aktivität berenteter Patienten. Die dem Operateur zur Verfügung
stehenden Messinstrumente, um die Patientenaktivität einzuschätzen, sind allenfalls begrenzt geeignet, die Patientenaktivität zu beurteilen. Der Operateur kann den Einfluss der Patientenaktivität auf die jährliche Abriebrate nur durch die Wahl der bestmöglichen Gleitpaarung minimieren.