Refine
Has Fulltext
- yes (23)
Is part of the Bibliography
- yes (23)
Year of publication
Document Type
- Journal article (19)
- Conference Proceeding (2)
- Book (1)
- Book article / Book chapter (1)
Keywords
- Toxikologie (5)
- Chemie (4)
- Biochemie (2)
- Anatomie (1)
- Anorganische Chemie (1)
- Apoptosis (1)
- B lymphocytes (1)
- CD23 (1)
- CLL (1)
- DNA methylation (1)
Institute
- Theodor-Boveri-Institut für Biowissenschaften (8)
- Institut für Anorganische Chemie (5)
- Institut für Pharmakologie und Toxikologie (5)
- Abteilung für Molekulare Innere Medizin (in der Medizinischen Klinik und Poliklinik II) (1)
- Comprehensive Cancer Center Mainfranken (1)
- Institut für Theoretische Physik und Astrophysik (1)
- Kinderklinik und Poliklinik (1)
- Klinik und Poliklinik für Dermatologie, Venerologie und Allergologie (1)
- Klinik und Poliklinik für Nuklearmedizin (1)
- Neurologische Klinik und Poliklinik (1)
No abstract available
Tyrosine kinase inhibitors (TKIs) such as vandetanib have shown clinical effectiveness in advanced medullary thyroid cancer (MTC). During TKI treatment, fluctuations in the tumor markers carcinoembryonic antigen (CEA) and calcitonin (CTN) are frequently observed. Their role for treatment monitoring and the decision-making process has not been fully elucidated yet.
Twenty-one patients (male, 16, female, 5; mean age, 49±13 years) with progressive MTC receiving vandetanib (300mg orally per day) were considered. Tumor restaging was performed every 3 months including contrast-enhanced computed tomography (CT). Response was assessed according to recent criteria (Response Evaluation Criteria in Solid Tumors, RECIST 1.1). Additionally, CEA and CTN were measured at the day of CT imaging and alterations observed in tumor markers were compared to respective imaging findings (partial response, PR; stable disease, SD; progressive disease, PD).
During long-term follow-up (510±350 days [range, 97-1140 days]), CTN and CEA levels initially dropped in 71.4% and 61.9% of the patients followed by fluctuations in serum marker levels. A rise in CTN ≥39.5% between 2 subsequent measurements (defined by ROC analysis) had a sensitivity of 70.6% and a specificity of 83.2% in predicting PD with an accuracy of 82.0% (area under the curve (AUC), 0.76). Oscillations in CEA levels were not predictive for PD.
Whereas tumor marker fluctuations in MTC patients undergoing TKI treatment are a frequent phenomenon, a significant rise in CTN ≥40% turns out to as an early indicator of tumor progression.
Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304\(\pm\)0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of \(\pm\)0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies.