Refine
Has Fulltext
- yes (2)
Is part of the Bibliography
- yes (2)
Year of publication
- 2014 (2) (remove)
Document Type
- Journal article (2)
Language
- English (2)
Keywords
- Angst (1)
- Barbed suture (1)
- Barbed suture material (1)
- Depression (1)
- Flexor tendon repair (1)
- Knotless tendon repair (1)
- Psychopharmakologie (1)
- Psychotherapie (1)
- Stratafix (1)
- V-Loc (1)
Background: The rapid progress of psychosomatic research in cardiology and also the increasing impact of psychosocial issues in the clinical daily routine have prompted the Clinical Commission of the German Heart Society (DGK) to agree to an update of the first state of the art paper on this issue which was originally released in 2008.
Methods: The circle of experts was increased, general aspects were implemented and the state of the art was updated. Particular emphasis was dedicated to coronary heart diseases (CHD), heart rhythm diseases and heart failure because to date the evidence-based clinical knowledge is most advanced in these particular areas. Differences between men and women and over the life span were considered in the recommendations as were influences of cognitive capability and the interactive and synergistic impact of classical somatic risk factors on the affective comorbidity in heart disease patients.
Results: A IA recommendation (recommendation grade I and evidence grade A) was given for the need to consider psychosocial risk factors in the estimation of coronary risks as etiological and prognostic risk factors. Furthermore, for the recommendation to routinely integrate psychosocial patient management into the care of heart surgery patients because in these patients, comorbid affective disorders (e.g. depression, anxiety and post-traumatic stress disorder) are highly prevalent and often have a malignant prognosis. A IB recommendation was given for the treatment of psychosocial risk factors aiming to prevent the onset of CHD, particularly if the psychosocial risk factor is harmful in itself (e.g. depression) or constrains the treatment of the somatic risk factors. Patients with acute and chronic CHD should be offered anti-depressive medication if these patients suffer from medium to severe states of depression and in this case medication with selective reuptake inhibitors should be given. In the long-term course of treatment with implanted cardioverter defibrillators (ICDs) a subjective health technology assessment is warranted. In particular, the likelihood of affective comorbidities and the onset of psychological crises should be carefully considered.
Conclusions: The present state of the art paper presents an update of current empirical evidence in psychocardiology. The paper provides evidence-based recommendations for the integration of psychosocial factors into cardiological practice and highlights areas of high priority. The evidence for estimating the efficiency for psychotherapeutic and psychopharmacological interventions has increased substantially since the first release of the policy document but is, however, still weak. There remains an urgent need to establish curricula for physician competence in psychodiagnosis, communication and referral to ensure that current psychocardiac knowledge is translated into the daily routine.
Background
Barbed suture material offers the possibility of knotless flexor tendon repair, as suggested in an increasing number of biomechanical studies. There are currently two different absorbable barbed suture products available, V-Loc™ and Stratafix™, and both have not been compared to each other with regard to flexor tendon repair. The purpose of this study was to evaluate both suture materials for primary stability under static and cyclic loading in a biomechanical ex vivo model.
Methods
Forty fresh porcine flexor digitorum profundus tendons were randomized in two groups. A four-strand modified Kessler suture technique was used to repair the tendon either with a 3–0 V-Loc™ or 3–0 Stratafix™ without a knot. Parameters of interest were mode of failure, 2-mm gap formation force, displacement, stiffness and maximum load under static and cyclic testing.
Results
The maximum load was 42.3 ± 7.2 for the Stratafix™ group and 50.7 ± 8.8 N for the V-Loc™ group. Thus, the ultimate tensile strength was significantly higher for V-Loc™ (p < 0.05). The 2-mm gap occurred at 24.8 ± 2.04 N in the Stratafix™ group in comparison to 26.5 ± 2.12 N in the V-Loc™ group (n.s.). Displacement was 2.65 ± 0.56 mm in the V-Loc™ group and 2.71 ± 0.59 mm in the Stratafix™ group (n.s.). Stiffness was 4.24 ± 0.68 (N/mm) in the V-Loc™ group and 3.85 ± 0.55 (N/mm) the Stratafix™ group (n.s.). Those measured differences were not significant.
Conclusion
V-Loc™ demonstrates a higher maximum load in tendon reconstruction. The differences in 2-mm gap formation force, displacement and stiffness were not significant. Hereby, the V-Loc™ has an advantage when used as unidirectional barbed suture for knotless flexor tendon repair.