Background/Aims:
Acute kidney injury (AKI) is a postoperative complication after cardiac surgery with a high impact on mortality and morbidity. Nephrocheck® [TIMP-2*IGFBP7] determines markers of tubular stress, which occurs prior to tubular damage. It is unknown at which time-point [TIMP-2*IGFBP7] measurement should be performed to ideally predict AKI. We investigated the association of [TIMP-2*IGFBP7] at various time-points with the incidence of AKI in patients undergoing elective cardiac surgery including cardio-pulmonary bypass.
Methods: In a prospective cohort study, serial blood and urine samples were collected from 150 patients: pre-operative, at ICU-admission, 24h and 48h post-surgery. AKI was defined as Serum-Creatinine rise >0.3 mg/dl within 48hrs. Urinary [TIMP-2*IGFBP7] was measured at pre-operative, ICU-admission and 24h post-surgery; medical staff was kept blinded to these results.
Results: A total of 35 patients (23.5%) experienced AKI, with a higher incidence in those with high [TIMP-2*IGFBP7] values at ICU admission (57.1% vs. 10.1%, p<0.001). In logistic regression [TIMP-2*IGFBP7] at ICU admission was independently associated with the occurrence of AKI (Odds Ratio 11.83; p<0.001, C-statistic= 0.74) after adjustment for EuroSCORE II and CBP-time.
Conclusions: Early detection of elevated [TIMP-2*IGFBP7] at ICU admission was strongly predictive for postoperative AKI and appeared to be more precise as compared to subsequent measurements.
Background:
There is growing evidence from the literature that right anterior minithoracotomy aortic valve replacement (RAT-AVR) improves clinical outcome. However, increased cross clamp time is the strongest argument for surgeons not performing RAT-AVR. Rapid deployment aortic valve systems have the potential to decrease cross-clamp time and ease this procedure. We assessed clinical outcome of rapid deployment and conventional valves through RAT.
Methods:
Sixty-eight patients (mean age 76 ± 6 years, 32% females) underwent RAT-AVR between 9/2013 and 7/2015. According to the valve type implanted the patients were divided into two groups. In 43 patients (R-group; mean age 74.1 ± 6.6 years) a rapid deployment valve system (Edwards Intuity, Edwards Lifesciences Corp; Irvine, Calif) and in 25 patients (C-group; mean age 74.2 ± 6.6 years) a conventional stented biological aortic valve was implanted.
Results:
Aortic cross-clamp (42.1 ± 12 min vs. 68.3 ± 20.3 min; p < 0.001) and bypass time (80.4 ± 39.3 min vs. 106.6 ± 23.2 min; p = 0.001) were shorter in the rapid deployment group (R-group). We observed no differences in clinical outcome. Postoperative gradients (R-group: max gradient, 14.3 ± 8 mmHg vs. 15.5 ± 5 mmHg (C-group), mean gradient, 9.2 ± 1.7 mmHg (R-group) vs. 9.1 ± 2.3 mmHg (C-group) revealed no differences. However, larger prostheses were implanted in C-group (25 mm; IQR 23–27 mm vs. 23 mm; IQR 21–25; p = 0.009).
Conclusions:
Our data suggest that the rapid deployment aortic valve system reduced cross clamp and bypass time in patients undergoing RAT-AVR with similar hemodynamics as with larger size stented prosthesis. However, larger studies and long-term follow-up are mandatory to confirm our findings.