Refine
Has Fulltext
- yes (21)
Is part of the Bibliography
- yes (21)
Year of publication
Document Type
- Journal article (21)
Keywords
- surgery (4)
- Barbed suture (1)
- Barbed suture material (1)
- Blepharoplastik (1)
- Digitalisierung (1)
- Elderly patients (1)
- Flexor tendon repair (1)
- Gesundheits-App (1)
- Knotless tendon repair (1)
- Künstliche Intelligenz (1)
Institute
- Klinik und Poliklinik für Unfall-, Hand-, Plastische und Wiederherstellungschirurgie (Chirurgische Klinik II) (20)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (3)
- Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I) (2)
- Medizinische Klinik und Poliklinik II (2)
- Abteilung für Funktionswerkstoffe der Medizin und der Zahnheilkunde (1)
- Institut für Anatomie und Zellbiologie (1)
- Klinik und Poliklinik für Dermatologie, Venerologie und Allergologie (1)
- Klinik und Poliklinik für Mund-, Kiefer- und Plastische Gesichtschirurgie (1)
- Lehrstuhl für Orthopädie (1)
- Lehrstuhl für Tissue Engineering und Regenerative Medizin (1)
Background
To cover soft tissue defects, the perforator-based propeller flap offers the option to rotate healthy tissue into complex wounds. By rotating the flap, the perforator is torqued. As a result, perfusion changes are possible.
Methods
A retrospective data analysis of patients was done, who received a propeller flap to cover soft tissue defects of the lower extremity as well as a peri- and postoperative perfusion monitoring with a laser-Doppler-spectrophotometry system. Additionally, patient-specific data were collected.
Results
Seven patients were identified. Four patients experienced early complications, two epidermolysis of the distal flap areas, three wound healing disorders, and one partial flap necrosis. Intraoperative perfusion monitoring showed a decline of blood flow after incision of the flap, especially at distal flap site. In case of complications, there were prolonged blood flow declines up to the first postoperative day.
Conclusion
Torqueing the perforator by rotating the flap can cause an impairment in inflow and outflow. If the impairment is prolonged, perfusion-associated complications are possible. The identification of a viable perforator is particularly important. In addition, a conservative postoperative mobilization is necessary to compensate for the impaired and adapting outflow.
Background
Traumatic separation of the pubic symphysis can destabilize the pelvis and require surgical fixation to reduce symphyseal gapping. The traditional approach involves open reduction and the implantation of a steel symphyseal plate (SP) on the pubic bone to hold the reposition. Despite its widespread use, SP-fixation is often associated with implant failure caused by screw loosening or breakage.
Methods
To address the need for a more reliable surgical intervention, we developed and tested two titanium cable-clamp implants. The cable served as tensioning device while the clamp secured the cable to the bone. The first implant design included a steel cable anterior to the pubic symphysis to simplify its placement outside the pelvis, and the second design included a cable encircling the pubic symphysis to stabilize the anterior pelvic ring. Using highly reproducible synthetic bone models and a limited number of cadaver specimens, we performed a comprehensive biomechanical study of implant stability and evaluated surgical feasibility.
Results
We were able to demonstrate that the cable-clamp implants provide stability equivalent to that of a traditional SP-fixation but without the same risks of implant failure. We also provide detailed ex vivo evaluations of the safety and feasibility of a trans-obturator surgical approach required for those kind of fixation.
Conclusion
We propose that the developed cable-clamp fixation devices may be of clinical value in treating pubic symphysis separation.
Muscle cuff in distal pedicled adipofascial sural artery flaps: a retrospective case control study
(2021)
Background:
Amputation after open tibial fracture occurs in 3% of cases. The rate increases when flap reconstruction is required. The standard care involves microsurgical tissue transfer although the pedicled reverse sural artery adipofascial flap (PRSAF) is a local alternative in patients endangered by a prolonged operative time. Incorporation of a gastrocnemius muscle cuff in this flap can be used to fill dead space and increase healing potential. Literature shows superior survival rates for both PRSAF and inclusion of a muscle cuff in comparison with the cutaneous version. The aim of the study was to compare the outcome of the PRSAF and the musculoadipofascial version (PRSMAF). We hypothesize that the PRSMAF provides similar lap viability and flap-related complication rates as does the adipofascial version. The muscle component may reduce the long-term osteomyelitis rate.
Methods:
Patients were evaluated retrospectively after reconstruction with either PRSAF or PRSMAF. Preoperative osteomyelitis, flap survival, complications and osteomyelitis clearance were analyzed.
Results:
The study shows preliminary results supporting the potential use of the PRSMAF. We compare either 23 PRSMAF or 20 PRSAF flaps. We found no statistically significant differences in flap survival or in complication rate.
Conclusions:
Although the anatomical situation may sometimes dictate the use of a free flap, a technically less-complicated option may in some cases offer a viable alternative. This study shows that the PRSMAF can serve as an alternative for complex bone defects in the limb, though it does not provide statistical improvement to the PRSAF.
Die operative Verjüngung des Auges stellt einen der am häufigsten nachgefragten Eingriffe im ästhetischen Spektrum dar. Die multikulturelle Bevölkerungsstruktur bedingt, dass auch „asiatisch“ imponierende Augen behandelt werden. „Asiatische“ Augen sind aber nicht nur bei Asiaten anzutreffen, sondern in unterschiedlicher Ausprägung auch bei Patienten aus dem Nahen und Mittleren Osten. Das asiatische Auge stellt in Bezug auf Verjüngungsmöglichkeiten eine eigene Entität dar. Während die klassische „Korrektur“ des asiatischen Auges eine etablierte und durch eine Vielzahl von verschiedenen Techniken mit vorhersehbaren Ergebnissen verbundene Methode ist, ist eine „verjüngende“ Blepharoplastik des asiatischen Auges komplexer zu bewerten [1, 3, 5, 10]. Die Operationsmethoden für das „asiatische“ Auge sind für jüngere Patienten intendiert, bei denen es überwiegend um die Korrektur des Epikanthus geht. Diese Techniken ziehen eine gewünschte Veränderung des periorbitalen Erscheinungsbildes nach sich, wobei das asiatische Aussehen teilweise zugunsten eines vermehrt „europäischen“ Aussehens beeinflusst wird. Fraglich bleibt, ob eine Veränderung zu einem europäischen Aussehen hin auch bei einem alternden Patienten einer Verjüngung gleichkommt. Prinzipiell imponiert ein derart operiertes asiatisches Auge „künstlich“, eine Tatsache die bei alternden Patienten als noch störender als der Alterungsprozess selbst empfunden werden dürfte. Daher ist der Wunsch nach einer Verjüngung ohne Verlust des typischen asiatischen Erscheinungsbildes des Auges chirurgisch nicht mit der klassischen Technik bei Europäern umzusetzen. Während die Behandlung durch eine klassische Blepharoplastik ein unnatürliches Aussehen zur Folge hat, kann unter Respektierung der asiatischen anatomischen Besonderheiten eine natürlich wirkende Verjüngung erreicht werden.
Objectives
Triangular fibrocartilage complex (TFCC) injuries frequently cause ulnar-sided wrist pain and can induce distal radioulnar joint instability. With its complex three-dimensional structure, diagnosis of TFCC lesions remains a challenging task even in MR arthrograms. The aim of this study was to assess the added diagnostic value of radial reformatting of isotropic 3D MRI datasets compared to standard planes after direct arthrography of the wrist.
Methods
Ninety-three patients underwent wrist MRI after fluoroscopy-guided multi-compartment arthrography. Two radiologists collectively analyzed two datasets of each MR arthrogram for TFCC injuries, with one set containing standard reconstructions of a 3D thin-slice sequence in axial, coronal and sagittal orientation, while the other set comprised an additional radial plane view with the rotating center positioned at the ulnar styloid. Surgical reports (whenever available) or radiological reports combined with clinical follow-up served as a standard of reference. In addition, diagnostic confidence and assessability of the central disc and ulnar-sided insertions were subjectively evaluated.
Results
Injuries of the articular disc, styloid and foveal ulnar attachment were present in 20 (23.7%), 10 (10.8%) and 9 (9.7%) patients. Additional radial planes increased diagnostic accuracy for lesions of the styloid (0.83 vs. 0.90; p = 0.016) and foveal (0.86 vs. 0.94; p = 0.039) insertion, whereas no improvement was identified for alterations of the central cartilage disc. Readers' confidence (p < 0.001) and assessability of the ulnar-sided insertions (p < 0.001) were superior with ancillary radial reformatting.
Conclusions
Access to the radial plane view of isotropic 3D sequences in MR arthrography improves diagnostic accuracy and confidence for ulnar-sided TFCC lesions.
Clinically used mineral bone cements lack high strength values, absorbability and drillability. Therefore, magnesium phosphate cements have recently received increasing attention as they unify a high mechanical performance with presumed degradation in vivo. To obtain a drillable cement formulation, farringtonite (Mg\(_3\)(PO\(_4\))\(_2\)) and magnesium oxide (MgO) were modified with the setting retardant phytic acid (C\(_6\)H\(_{18}\)O\(_{24}\)P\(_6\)). In a pre-testing series, 13 different compositions of magnesium phosphate cements were analyzed concentrating on the clinical demands for application. Of these 13 composites, two cement formulations with different phytic acid content (22.5 wt% and 25 wt%) were identified to meet clinical demands. Both formulations were evaluated in terms of setting time, injectability, compressive strength, screw pullout tests and biomechanical tests in a clinically relevant fracture model. The cements were used as bone filler of a metaphyseal bone defect alone, and in combination with screws drilled through the cement. Both formulations achieved a setting time of 5 min 30 s and an injectability of 100%. Compressive strength was shown to be ~12–13 MPa and the overall displacement of the reduced fracture was <2 mm with and without screws. Maximum load until reduced fracture failure was ~2600 N for the cements only and ~3800 N for the combination with screws. Two new compositions of magnesium phosphate cements revealed high strength in clinically relevant biomechanical test set-ups and add clinically desired characteristics to its strength such as injectability and drillability.
Background
Gastric pull-up (GPU) procedures may be complicated by leaks, fistulas, or stenoses. These complications are usually managed by endoscopy, but in extreme cases multidisciplinary management including reoperation may be necessary. Here, we report a combined endoscopic and surgical approach to manage a failed secondary GPU procedure.
Case summary
A 70-year-old male with treatment-refractory cervical esophagocutaneous fistula with stenotic remnant esophagus after secondary GPU was transferred to our tertiary hospital. Local and systemic infection originating from the infected fistula was resolved by endoscopy. Hence, elective esophageal reconstruction with free-jejunal interposition was performed with no subsequent adverse events.
Conclusion
A multidisciplinary approach involving interventional endoscopists and surgeons successfully managed severe complications arising from a cervical esophago-cutaneous fistula after GPU. Endoscopic treatment may have lowered the perioperative risk to promote primary wound healing after free-jejunal graft interposition.
Hintergrund
Die Fotodokumentation von offenen Frakturen, Wunden, Dekubitalulzera, Tumoren oder Infektionen ist ein wichtiger Bestandteil der digitalen Patientenakte. Bisher ist unklar, welchen Stellenwert diese Fotodokumentation bei der Abrechnungsprüfung durch den Medizinischen Dienst der Krankenkassen (MDK) hat.
Fragestellung
Kann eine Smartphone-basierte Fotodokumentation die Verteidigung von erlösrelevanten Diagnosen und Prozeduren sowie der Verweildauer verbessern?
Material und Methoden
Ausstattung der Mitarbeiter mit digitalen Endgeräten (Smartphone/Tablet) in den Bereichen Notaufnahme, Schockraum, OP, Sprechstunden sowie auf den Stationen. Retrospektive Auswertung der Abrechnungsprüfung im Jahr 2019 und Identifikation aller Fallbesprechungen, in denen die Fotodokumentation eine Erlösveränderung bewirkt hat.
Ergebnisse
Von insgesamt 372 Fallbesprechungen half die Fotodokumentation in 27 Fällen (7,2 %) zur Bestätigung eines Operationen- und Prozedurenschlüssels (OPS) (n = 5; 1,3 %), einer Hauptdiagnose (n = 10; 2,7 %), einer Nebendiagnose (n = 3; 0,8 %) oder der Krankenhausverweildauer (n = 9; 2,4 %). Pro oben genanntem Fall mit Fotodokumentation ergab sich eine durchschnittliche Erlössteigerung von 2119 €. Inklusive Aufwandpauschale für die Verhandlungen wurde somit ein Gesamtbetrag von 65.328 € verteidigt.
Diskussion
Der Einsatz einer Smartphone-basierten Fotodokumentation kann die Qualität der Dokumentation verbessern und Erlöseinbußen bei der Abrechnungsprüfung verhindern. Die Implementierung digitaler Endgeräte mit entsprechender Software ist ein wichtiger Teil des digitalen Strukturwandels in Kliniken.
Due to the rapidly increasing development and use of cellular products, there is a rising demand for non-animal-based test platforms to predict, study and treat undesired immunity. Here, we generated human organotypic skin models from human biopsies by isolating and expanding keratinocytes, fibroblasts and microvascular endothelial cells and seeding these components on a collagen matrix or a biological vascularized scaffold matrix in a bioreactor. We then were able to induce inflammation-mediated tissue damage by adding pre-stimulated, mismatched allogeneic lymphocytes and/or inflammatory cytokine-containing supernatants histomorphologically mimicking severe graft versus host disease (GvHD) of the skin. This could be prevented by the addition of immunosuppressants to the models. Consequently, these models harbor a promising potential to serve as a test platform for the prediction, prevention and treatment of GvHD. They also allow functional studies of immune effectors and suppressors including but not limited to allodepleted lymphocytes, gamma-delta T cells, regulatory T cells and mesenchymal stromal cells, which would otherwise be limited to animal models. Thus, the current test platform, developed with the limitation that no professional antigen presenting cells are in place, could greatly reduce animal testing for investigation of novel immune therapies.
Background: The soft tissue of the central pretibial area is difficult to reconstruct often requiring free tissue transfer. Especially medi- cally compromised patients are not ideal candidates for free tissue transfer and may benefit from expeditiously harvested local flaps with limited donor site morbidity. As muscle flaps are rare, pedi- cled flaps based on lateral perforators represent an alternative as the arc of rotation can often be limited to 90 °.
Material and Methods: A retrospective analysis of patient data was conducted to identify patients over the age of 60 years with comor- bidities that underwent pretibial soft tissue reconstruction with a single-pedicle perforator flap. Patient demographics, size and cause of the defect, flap dimension, arc of rotation and complications were recorded.
Results: Five patients with an average age of 71.4 years were in- cluded. The arc of rotation was 69 °, all flaps healed. There were two recurrences of osteomyelitis.
Conclusion: Lateral perforators originating from the anterior tib- ial artery or peroneal artery are adequate source vessels for single pedicled perforator flaps even in medically compromised patients. A perforator located proximal to the defect allows limiting the arcof rotation to less than 90 °, which increases the safety of the flap. Patients benefit from a simple procedure without a microvascular anastomosis and a donor site confined to one extremity