Refine
Has Fulltext
- yes (21)
Is part of the Bibliography
- yes (21) (remove)
Year of publication
Document Type
- Journal article (20)
- Doctoral Thesis (1)
Keywords
- Mechanisms (2)
- ARIA (1)
- Age (1)
- Alzheimers disease (1)
- Antibody (1)
- Apoptosis (1)
- Argentina (1)
- Argentinien (1)
- Auslandsinvestition (1)
- B cell receptors (1)
Institute
- Theodor-Boveri-Institut für Biowissenschaften (7)
- Julius-von-Sachs-Institut für Biowissenschaften (4)
- Institut für Informatik (3)
- Lehrstuhl für Tissue Engineering und Regenerative Medizin (3)
- Abteilung für Molekulare Innere Medizin (in der Medizinischen Klinik und Poliklinik II) (2)
- Institut für Theoretische Physik und Astrophysik (2)
- Kinderklinik und Poliklinik (2)
- Klinik und Poliklinik für Mund-, Kiefer- und Plastische Gesichtschirurgie (2)
- Augenklinik und Poliklinik (1)
- Fakultät für Physik und Astronomie (1)
Sonstige beteiligte Institutionen
EU-Project number / Contract (GA) number
- 614623 (1)
Precision-cut tumor slices (PCTS) maintain tissue heterogeneity concerning different cell types and preserve the tumor microenvironment (TME). Typically, PCTS are cultured statically on a filter support at an air–liquid interface, which gives rise to intra-slice gradients during culture. To overcome this problem, we developed a perfusion air culture (PAC) system that can provide a continuous and controlled oxygen medium, and drug supply. This makes it an adaptable ex vivo system for evaluating drug responses in a tissue-specific microenvironment. PCTS from mouse xenografts (MCF-7, H1437) and primary human ovarian tumors (primary OV) cultured in the PAC system maintained the morphology, proliferation, and TME for more than 7 days, and no intra-slice gradients were observed. Cultured PCTS were analyzed for DNA damage, apoptosis, and transcriptional biomarkers for the cellular stress response. For the primary OV slices, cisplatin treatment induced a diverse increase in the cleavage of caspase-3 and PD-L1 expression, indicating a heterogeneous response to drug treatment between patients. Immune cells were preserved throughout the culturing period, indicating that immune therapy can be analyzed. The novel PAC system is suitable for assessing individual drug responses and can thus be used as a preclinical model to predict in vivo therapy responses.
Digital anamorphosis is used to define a distorted image of health and care that may be viewed correctly using digital tools and strategies. MASK digital anamorphosis represents the process used by MASK to develop the digital transformation of health and care in rhinitis. It strengthens the ARIA change management strategy in the prevention and management of airway disease. The MASK strategy is based on validated digital tools. Using the MASK digital tool and the CARAT online enhanced clinical framework, solutions for practical steps of digital enhancement of care are proposed.
A new innovative satellite mission, the Innovative CubeSat for Education (InnoCube), is addressed. The goal of the mission is to demonstrate “the wireless satellite”, which replaces the data harness by robust, high-speed, real-time, very short-range radio communications using the SKITH (SKIpTheHarness) technology. This will make InnoCube the first wireless satellite in history. Another technology demonstration is an experimental energy-storing satellite structure that was developed in the previous Wall#E project and might replace conventional battery technology in the future. As a further payload, the hardware for the concept of a software-based solution for receiving signals from Global Navigation Satellite Systems (GNSS) will be developed to enable precise position determination of the CubeSat. Aside from technical goals this work aims to be of use in the teaching of engineering skills and practical sustainable education of students, important technical and scientific publications, and the increase of university skills. This article gives an overview of the overall design of the InnoCube.
A new innovative real-time tracking method for flying insects applicable under natural conditions
(2021)
Background
Sixty percent of all species are insects, yet despite global efforts to monitor animal movement patterns, insects are continuously underrepresented. This striking difference between species richness and the number of species monitored is not due to a lack of interest but rather to the lack of technical solutions. Often the accuracy and speed of established tracking methods is not high enough to record behavior and react to it experimentally in real-time, which applies in particular to small flying animals.
Results
Our new method of real-time tracking relates to frequencies of solar radiation which are almost completely absorbed by traveling through the atmosphere. For tracking, photoluminescent tags with a peak emission (1400 nm), which lays in such a region of strong absorption through the atmosphere, were attached to the animals. The photoluminescent properties of passivated lead sulphide quantum dots were responsible for the emission of light by the tags and provide a superb signal-to noise ratio. We developed prototype markers with a weight of 12.5 mg and a diameter of 5 mm. Furthermore, we developed a short wave infrared detection system which can record and determine the position of an animal in a heterogeneous environment with a delay smaller than 10 ms. With this method we were able to track tagged bumblebees as well as hawk moths in a flight arena that was placed outside on a natural meadow.
Conclusion
Our new method eliminates the necessity of a constant or predictable environment for many experimental setups. Furthermore, we postulate that the developed matrix-detector mounted to a multicopter will enable tracking of small flying insects, over medium range distances (>1000m) in the near future because: a) the matrix-detector equipped with an 70 mm interchangeable lens weighs less than 380 g, b) it evaluates the position of an animal in real-time and c) it can directly control and communicate with electronic devices.
Background and Aims: Colonoscopy as standard procedure in endoscopy is often perceived as uncomfortable for patients. Patient's anxiety is therefore a significant issue, which often lead to avoidance of participation of relevant examinations as CRC-screening. Non-pharmacological anxiety management interventions such as music might contribute to relaxation in the phase prior and during endoscopy. Although music's anxiolytic effects have been reported previously, no objective measurement of stress level reduction has been reported yet. Focus of this study was to evaluate the objective measurement of the state of relaxation in patients undergoing colonoscopy.
Methods: Prospective study (n = 196) performed at one endoscopic high-volume center. Standard colonoscopy was performed in control group. Interventional group received additionally self-chosen music over earphones. Facial Electromyography (fEMG) activity was obtained. Clinician Satisfaction with Sedation Instrument (CSSI) and Patients Satisfaction with Sedation Instrument (PSSI) was answered by colonoscopists and patients, respectively. Overall satisfaction with music accompanied colonoscopy was obtained if applicable.
Results: Mean difference measured by fEMG via musculus zygomaticus major indicated a significantly lower stress level in the music group [7.700(±5.560) μV vs. 4.820(±3.330) μV; p = 0.001]. Clinician satisfaction was significantly higher with patients listening to music [82.69(±15.04) vs. 87.3(±15.02) pts.; p = 0.001]. Patient's satisfaction was higher but did not differ significantly.
Conclusions: We conclude that self-chosen music contributes objectively to a reduced stress level for patients and therefore subjectively perceived satisfaction for endoscopists. Therefore, music should be considered as a non-pharmacological treatment method of distress reduction especially in the beginning of endoscopic procedures.
Active Galactic Nuclei emit radiation over the whole electromagnetic spectrum up to TeV energies. Blazars are one subtype with their jets pointing towards the observer. One of their typical features is extreme variability on timescales, from minutes to years. The fractional variability is an often used parameter for investigating the degree of variability of a light curve. Different detection methods and sensitivities of the instruments result in differently binned data and light curves with gaps. As they can influence the physics interpretation of the broadband variability, the effects of these differences on the fractional variability need to be studied. In this paper, we study the systematic effects of completeness in time coverage and the sampling rate. Using public data from instruments monitoring blazars in various energy ranges, we study the variability of the bright TeV blazars Mrk 421 and Mrk 501 over the electromagnetic spectrum, taking into account the systematic effects, and compare our findings with previous results. Especially in the TeV range, the fractional variability is higher than in previous studies, which can be explained by the much longer (seven years compared to few weeks) and more complete data sample.
(1) Background: Refractory acute graft-versus-host disease (R-aGvHD) remains a leading cause of death after allogeneic stem cell transplantation. Survival rates of 15% after four years are currently achieved; deaths are only in part due to aGvHD itself, but mostly due to adverse effects of R-aGvHD treatment with immunosuppressive agents as these predispose patients to opportunistic infections and loss of graft-versus-leukemia surveillance resulting in relapse. Mesenchymal stromal cells (MSC) from different tissues and those generated by various protocols have been proposed as a remedy for R-aGvHD but the enthusiasm raised by initial reports has not been ubiquitously reproduced. (2) Methods: We previously reported on a unique MSC product, which was generated from pooled bone marrow mononuclear cells of multiple third-party donors. The products showed dose-to-dose equipotency and greater immunosuppressive capacity than individually expanded MSCs from the same donors. This product, MSC-FFM, has entered clinical routine in Germany where it is licensed with a national hospital exemption authorization. We previously reported satisfying initial clinical outcomes, which we are now updating. The data were collected in our post-approval pharmacovigilance program, i.e., this is not a clinical study and the data is high-level and non-monitored. (3) Results: Follow-up for 92 recipients of MSC-FFM was reported, 88 with GvHD ≥°III, one-third only steroid-refractory and two-thirds therapy resistant (refractory to steroids plus ≥2 additional lines of treatment). A median of three doses of MSC-FFM was administered without apparent toxicity. Overall response rates were 82% and 81% at the first and last evaluation, respectively. At six months, the estimated overall survival was 64%, while the cumulative incidence of death from underlying disease was 3%. (4) Conclusions: MSC-FFM promises to be a safe and efficient treatment for severe R-aGvHD.
This paper proposes a 3-D local pose estimation system for a small Unmanned Aerial Vehicle (UAV) with a weight limit of 200 g and a very small footprint of 10 cm×10cm. The system is realized by fusing 3-D position estimations from an Ultra-Wide Band (UWB) transceiver network with Inertial Measurement Unit (IMU) sensor data and data from a barometric pressure sensor. The 3-D position from the UWB network is estimated using Multi-Dimensional Scaling (MDS) and range measurements between the transceivers. The range measurements are obtained using Double-Sided Two-Way Ranging (DS-TWR), thus eliminating the need for an additional clock synchronization mechanism. The sensor fusion is accomplished using a loosely coupled Extended Kalman Filter (EKF) architecture. Extensive evaluation of the proposed system shows that a position accuracy with a Root-Mean-Square Error (RMSE) of 0.20cm can be obtained. The orientation angle can be estimated with an RMSE of 1.93°.
Blazars like Markarian 421 or Markarian 501 are active galactic nuclei (AGN), with their jets orientated towards the observer. They are among the brightest objects in the very high energy (VHE) gamma ray regime (>100 GeV). Their emitted gamma-ray fluxes are extremely variable, with changing activity levels on timescales between minutes, months, and even years. Several questions are part of the current research, such as the question of the emission regions or the engine of the AGN and the particle acceleration. A dedicated longterm monitoring program is necessary to investigate the properties of blazars in detail. A densely sampled and unbiased light curve allows for observation of both high and low states of the sources, and the combination with multi-wavelength observation could contribute to the answer of several questions mentioned above. FACT (First G-APD Cherenkov Telescope) is the first operational telescope using silicon photomultiplier (SiPM, also known as Geigermode—Avalanche Photo Diode, G-APD) as photon detectors. SiPM have a very homogenous and stable longterm performance, and allow operation even during full moon without any filter, leading to a maximal duty cycle for an Imaging Air Cherenkov Telescope (IACT). Hence, FACT is an ideal device for such a longterm monitoring of bright blazars. A small set of sources (e.g., Markarian 421, Markarian 501, 1ES 1959+650, and 1ES 2344+51.4) is currently being monitored. In this contribution, the FACT telescope and the concept of longterm monitoring of bright blazars will be introduced. The results of the monitoring program will be shown, and the advantages of densely sampled and unbiased light curves will be discussed.
Radiationless energy transfer is at the core of diverse phenomena, such as light harvesting in photosynthesis\(^1\), energy-transfer-based microspectroscopies\(^2\), nanoscale quantum entanglement\(^3\) and photonic-mode hybridization\(^4\). Typically, the transfer is efficient only for separations that are much shorter than the diffraction limit. This hampers its application in optical communication and quantum information processing, which require spatially selective addressing. Here, we demonstrate highly efficient radiationless coherent energy transfer over a distance of twice the excitation wavelength by combining localized and delocalized\(^5\) plasmonic modes. Analogous to the Tavis-Cummings model, two whispering-gallery-mode antennas\(^6\) placed in the foci of an elliptical plasmonic cavity\(^7\) fabricated from single-crystal gold plates act as a pair of oscillators coupled to a common cavity mode. Time-resolved two-photon photoemission electron microscopy (TR 2P-PEEM) reveals an ultrafast long-range periodic energy transfer in accordance with the simulations. Our observations open perspectives for the optimization and tailoring of mesoscopic energy transfer and long-range quantum emitter coupling.