Refine
Has Fulltext
- yes (29)
Is part of the Bibliography
- yes (29)
Year of publication
Document Type
- Journal article (27)
- Doctoral Thesis (2)
Keywords
- mouse (4)
- CMR (3)
- atherosclerosis (3)
- magnetic resonance imaging (3)
- pulse wave velocity (3)
- 4D flow (2)
- MOLLI (2)
- MRI (2)
- Medizin (2)
- T2 (2)
Institute
- Medizinische Klinik und Poliklinik I (22)
- Physikalisches Institut (14)
- Deutsches Zentrum für Herzinsuffizienz (DZHI) (6)
- Institut für Experimentelle Biomedizin (4)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (3)
- Institut für diagnostische und interventionelle Neuroradiologie (ehem. Abteilung für Neuroradiologie) (2)
- Medizinische Klinik und Poliklinik II (2)
- Comprehensive Cancer Center Mainfranken (1)
- Institut für Anatomie und Zellbiologie (1)
- Institut für Hygiene und Mikrobiologie (1)
Atherosclerosis is an inflammatory disease of large and medium-sized arteries, characterized by the growth of atherosclerotic lesions (plaques). These plaques often develop at inner curvatures of arteries, branchpoints, and bifurcations, where the endothelial wall shear stress is low and oscillatory. In conjunction with other processes such as lipid deposition, biomechanical factors lead to local vascular inflammation and plaque growth. There is also evidence that low and oscillatory shear stress contribute to arterial remodeling, entailing a loss in arterial elasticity and, therefore, an increased pulse-wave velocity. Although altered shear stress profiles, elasticity and inflammation are closely intertwined and critical for plaque growth, preclinical and clinical investigations for atherosclerosis mostly focus on the investigation of one of these parameters only due to the experimental limitations. However, cardiovascular magnetic resonance imaging (MRI) has been demonstrated to be a potent tool which can be used to provide insights into a large range of biological parameters in one experimental session. It enables the evaluation of the dynamic process of atherosclerotic lesion formation without the need for harmful radiation. Flow-sensitive MRI provides the assessment of hemodynamic parameters such as wall shear stress and pulse wave velocity which may replace invasive and radiation-based techniques for imaging of the vascular
function and the characterization of early plaque development. In combination with inflammation imaging, the analyses and correlations of these parameters could not only significantly advance basic preclinical investigations of atherosclerotic lesion formation and progression, but also the diagnostic clinical evaluation for early identification of high-risk plaques, which are prone to rupture. In this review, we summarize the key applications of magnetic resonance imaging for the evaluation of plaque characteristics through flow sensitive and morphological measurements. The simultaneous measurements of functional and structural parameters will further preclinical research on atherosclerosis and has the potential to fundamentally improve the detection of inflammation and vulnerable plaques in patients.
Growth, ageing and atherosclerotic plaque development alter the biomechanical forces acting on the vessel wall. However, monitoring the detailed local changes in wall shear stress (WSS) at distinct sites of the murine aortic arch over time has been challenging. Here, we studied the temporal and spatial changes in flow, WSS, oscillatory shear index (OSI) and elastic properties of healthy wildtype (WT, n = 5) and atherosclerotic apolipoprotein E-deficient (Apoe\(^{−/−}\), n = 6) mice during ageing and atherosclerosis using high-resolution 4D flow magnetic resonance imaging (MRI). Spatially resolved 2D projection maps of WSS and OSI of the complete aortic arch were generated, allowing the pixel-wise statistical analysis of inter- and intragroup hemodynamic changes over time and local correlations between WSS, pulse wave velocity (PWV), plaque and vessel wall characteristics. The study revealed converse differences of local hemodynamic profiles in healthy WT and atherosclerotic Apoe\(^{−/−}\) mice, and we identified the circumferential WSS as potential marker of plaque size and composition in advanced atherosclerosis and the radial strain as a potential marker for vascular elasticity. Two-dimensional (2D) projection maps of WSS and OSI, including statistical analysis provide a powerful tool to monitor local aortic hemodynamics during ageing and atherosclerosis. The correlation of spatially resolved hemodynamics and plaque characteristics could significantly improve our understanding of the impact of hemodynamics on atherosclerosis, which may be key to understand plaque progression towards vulnerability.
Auf der Suche nach neuen Vitamin D-responsiven Genen wurde die Methodik des Differential Display verwendet. Die eingesetzten Oligonukleotid-Primer waren homolog zur 24-Hydroxylase, einem für den Vitamin D-Stoffwechsel wichtigen Enzym, das von Vitamin D selbst reguliert wird. Mit diesem Ansatz sollten neue Mitglieder aus der Familie der P450-Enzyme gefunden werden. Mehrere differentiell exprimierte DNA-Fragmente wurden in der Folge isoliert und aufgearbeitet, die Sequenzierung eines 550 bp großen Fragments ergab beim Datenbankabgleich keine signifikanten Homologien und ließ daher auf ein noch unbekanntes Gen schließen. Die Klonierung und weitere Charakterisierung dieses Gens wies letztlich in eine nicht erwartete Richtung. Mit der Puromycin-sensitiven Aminopeptidase war ein Gen aus der Familie der Metallopeptidasen gefunden worden, eine Exopeptidase mit einem Zink-Ion im katalytischen Zentrum. Proteinchemisch schon vor einigen Jahren isoliert, war über die PSA (Puromycin-sensitive Aminopeptidase) bekannt, daß sie N-terminale Aminosäuren hydrolysiert mit einer Spezifität für basisch / neutrales und hydrophobes Substrat und überwiegend im Cytoplasma lokalisiert ist. Namengebend ist die starke Hemmbarkeit der Enzymaktivität durch Puromycin. Vorstehendes summiert die wichtigsten biochemischen Eigenschaften des Enzyms, aus molekularbiologischer Sicht war zum Zeitpunkt der Aufnahme der Arbeiten jedoch noch wenig über die PSA bekannt. Dies hat sich in letzter Zeit geändert, während der Sequenzierarbeiten im Rahmen dieser Arbeit konnte eine schweizer Arbeitsgruppe die Klonierung und Sequenz-Charakterisierung der murinen und später humanen cDNA des Gens veröffentlichen. Mit den Ergebnissen dieser Arbeitsgruppe wie auch den im Zuge der vorliegenden Dissertation erarbeiteten Resultaten konnte das molekularbiologische Wissen um die PSA erheblich erweitert werden. So liegt mittlerweile die komplette Nukleotid- und Aminosäurensequenz des Gens vor, das Auffinden des Zink-Bindungsmotives HEXXH(X)18E erlaubte die Einordnung des Enzyms in die Familie M1 der Metallopeptidasen, weiterhin konnte das Gen auf dem Chromosom 17q21 lokalisiert werden. Weitere Daten zur Gewebe- und Zellinienexpression sind nun ebenfalls vorhanden, interessant hierbei neben der erwartet starken Expression im Gehirn das deutliche Vorhandensein in Hoden und Nebennierenrinde. Auch in Bezug auf die Regulation der PSA wurden neue Ergebnisse erzielt, wichtigstes Resultat im Rahmen dieser Arbeit ist hier, daß sich die früher festgestellte Vitamin D –Responsivität nicht bestätigen ließ. Für die Zukunft von außerordentlichem Interesse dürfte das kürzlich gelungene Erstellen PSA-defizienter Mäuse sein, das nun erste Beobachtungen von Auswirkungen der Gen-Deletion am lebenden Organismus erlaubt. Trotz alledem sind in Bezug auf die physiologische Rolle der Puromycin-sensitiven Aminopeptidase weiterhin viele Fragen ungeklärt. Wie hoffentlich in dieser Dissertation herausgearbeitet, ergeben sich dabei interessante Perspektiven für die mögliche Funktion des Enzyms im Organismus.
Thermodynamics of Competitive Molecular Channel Transport: Application to Artificial Nuclear Pores
(2010)
In an analytical model channel transport is analyzed as a function of key parameters, determining efficiency and selectivity of particle transport in a competitive molecular environment. These key parameters are the concentration of particles, solvent-channel exchange dynamics, as well as particle-in-channel- and interparticle interaction. These parameters are explicitly related to translocation dynamics and channel occupation probability. Slowing down the exchange dynamics at the channel ends, or elevating the particle concentration reduces the in-channel binding strength necessary to maintain maximum transport. Optimized in-channel interaction may even shift from binding to repulsion. A simple equation gives the interrelation of access dynamics and concentration at this transition point. The model is readily transferred to competitive transport of different species, each of them having their individual in-channel affinity. Combinations of channel affinities are determined which differentially favor selectivity of certain species on the cost of others. Selectivity for a species increases if its in-channel binding enhances the species’ translocation probablity when compared to that of the other species. Selectivity increases particularly for a wide binding site, long channels, and fast access dynamics. Recent experiments on competitive transport of in-channel binding and inert molecules through artificial nuclear pores serve as a paradigm for our model. It explains qualitatively and quantitatively how binding molecules are favored for transport at the cost of the transport of inert molecules.
Die Dynamik der Kernspindephasierung in lebenden Systemen enhält relevante Informationen über biologisch wichtige Parameter, wie Sauerstoffversorgung, Mikrozirkulation, Diffusion etc.. Ursächlich für die Dephasierung sind Interaktionen des Spins mit fluktuierenden Magnetfeldern. Notwendig sind also Modelle, welche diese Interaktionen mit den biologisch relevanten Parametern in Beziehung setzen. Problematisch ist, daß fast alle analytische Ansätze nur in extremen Dynamikbereichen der Störfeldfluktuationen (motional narrowing - , static dephasing limit) gültig sind. In dieser Arbeit zeigen wir einen Ansatz, mit dem man die Dynamik der Störfeldfluktuationen erheblich vereinfachen und trotzdem noch deren wesentliche Eigenschaften beibehalten kann. Dieser Ansatz ist nicht auf einen speziellen Dynamikbereich festgelegt. Angewendet wird dieses Näherungsverfahren zur Beschreibung der Spin Dephasierung im Herzmuskel. Die Relaxationszeiten erhält man als Funktion der Kapillardichte und Blutoxygenierung. Vergleiche mit numerisch errechneten Daten anderer, eigenen Messungen am menschlichen Herzen und experimentellen Befunden in der Literatur, bestätigen die theoretischen Vorhersagen.
Impact of Interparticle Interaction on Thermodynamics of Nano-Channel Transport of Two Species
(2020)
Understanding the function and control of channel transport is of paramount importance for cell physiology and nanotechnology. In particular, if several species are involved, the mechanisms of selectivity, competition, cooperation, pumping, and its modulation need to be understood. What lacks is a rigorous mathematical approach within the framework of stochastic thermodynamics, which explains the impact of interparticle in-channel interactions on the transport properties of the respective species. To achieve this, stochastic channel transport of two species is considered in a model, which different from mean field approaches, explicitly conserves the spatial correlation of the species within the channel by analysis of the stochastic dynamics within a state space, the elements of which are the channel’s spatial occupation states. The interparticle interactions determine the stochastic transitions between these states. Local flow and entropy production in this state space reveal the respective particle flows through the channel and the intensity of the Brownian ratchet like rectifying forces, which these species exert mutually on each other, together with its thermodynamic effectiveness and costs. Perfect coupling of transport of the two species is realized by an attractive empty channel and strong repulsive forces between particles of the same species. This confines the state space to a subspace with circular topology, in which the concentration gradients as thermodynamic driving forces act in series, and channel flow of both species becomes equivalent. For opposing concentration gradients, this makes the species with the stronger gradient the driving, positive entropy producing one; the other is driven and produces negative entropy. Gradients equal in magnitude make all flows vanish, and thermodynamic equilibrium occurs. A differential interparticle interaction with less repulsive forces within particles of one species but maintenance of this interaction for the other species adds a bypass path to this circular subspace. On this path, which is not involved in coupling of the two species, a leak flow of the species with less repulsive interparticle interaction emerges, which is directed parallel to its concentration gradient and, hence, produces positive entropy here. Different from the situation with perfect coupling, appropriate strong opposing concentration gradients may simultaneously parallelize the flow of their respective species, which makes each species produce positive entropy. The rectifying potential of the species with the bypass option is diminished. This implies the existence of a gradient of the other species, above which its flow and gradient are parallel for any gradient of the less coupled species. The opposite holds for the less coupled species. Its flow may always be rectified and turned anti-parallel to its gradient by a sufficiently strong opposing gradient of the other one.
Early healing after myocardial infarction (MI) is characterized by a strong inflammatory reaction. Most leukotrienes are pro-inflammatory and are therefore potential mediators of healing and remodeling after myocardial ischemia. The enzyme 5-lipoxygenase (5-LOX) has a key role in the transformation of arachidonic acid in leukotrienes. Thus, we tested the effect of 5-LOX on healing after MI. After chronic coronary artery ligation, early mortality was significantly increased in 5-LOX\(^{−/−}\) when compared to matching wildtype (WT) mice due to left ventricular rupture. This effect could be reproduced in mice treated with the 5-LOX inhibitor Zileuton. A perfusion mismatch due to the vasoactive potential of leukotrienes is not responsible for left ventricular rupture since local blood flow assessed by magnetic resonance perfusion measurements was not different. However, after MI, there was an accentuation of the inflammatory reaction with an increase of pro-inflammatory macrophages. Yet, mortality was not changed in chimeric mice (WT vs. 5-LOX\(^{−/−}\) bone marrow in 5-LOX\(^{−/−}\) animals), indicating that an altered function of 5-LOX\(^{−/−}\) inflammatory cells is not responsible for the phenotype. Collagen production and accumulation of fibroblasts were significantly reduced in 5-LOX\(^{−/−}\) mice in vivo after MI. This might be due to an impaired migration of 5-LOX\(^{−/−}\) fibroblasts, as shown in vitro to serum. In conclusion, a lack or inhibition of 5-LOX increases mortality after MI because of healing defects. This is not mediated by a change in local blood flow, but through an altered inflammation and/or fibroblast function.
Increased aortic stiffness is known to be associated with atherosclerosis and has a predictive value for cardiovascular events. This study aims to investigate the local distribution of early arterial stiffening due to initial atherosclerotic lesions. Therefore, global and local pulse wave velocity (PWV) were measured in ApoE\(^{-/-}\) and wild type (WT) mice using ultrahigh field MRI. For quantification of global aortic stiffness, a new multi-point transit-time (TT) method was implemented and validated to determine the global PWV in the murine aorta. Local aortic stiffness was measured by assessing the local PWV in the upper abdominal aorta, using the flow/area (QA) method. Significant differences between age matched ApoE\(^{-/-}\) and WT mice were determined for global and local PWV measurements (global PWV: ApoE\(^{-/-}\): 2.7 ±0.2m/s vs WT: 2.1±0.2m/s, P<0.03; local PWV: ApoE\(^{-/-}\): 2.9±0.2m/s vs WT: 2.2±0.2m/s, P<0.03). Within the WT mouse group, the global PWV correlated well with the local PWV in the upper abdominal aorta (R\(^2\) = 0.75, P<0.01), implying a widely uniform arterial elasticity.
In ApoE\(^{-/-}\) animals, however, no significant correlation between individual local and global PWV was present (R\(^2\) = 0.07, P = 0.53), implying a heterogeneous distribution of vascular stiffening in early atherosclerosis. The assessment of global PWV using the new multi-point TT measurement technique was validated against a pressure wire measurement in a vessel
phantom and showed excellent agreement. The experimental results demonstrate that vascular stiffening caused by early atherosclerosis is unequally distributed over the length of large vessels. This finding implies that assessing heterogeneity of arterial stiffness by multiple local measurements of PWV might be more sensitive than global PWV to identify early atherosclerotic lesions.
Background:
Local aortic pulse wave velocity (PWV) is a measure for vascular stiffness and has a predictive value for cardiovascular events. Ultra high field CMR scanners allow the quantification of local PWV in mice, however these systems are yet unable to monitor the distribution of local elasticities.
Methods:
In the present study we provide a new accelerated method to quantify local aortic PWV in mice with phase-contrast cardiovascular magnetic resonance imaging (PC-CMR) at 17.6 T. Based on a k-t BLAST (Broad-use Linear Acquisition Speed-up Technique) undersampling scheme, total measurement time could be reduced by a factor of 6. The fast data acquisition enables to quantify the local PWV at several locations along the aortic blood vessel based on the evaluation of local temporal changes in blood flow and vessel cross sectional area. To speed up post processing and to eliminate operator bias, we introduce a new semi-automatic segmentation algorithm to quantify cross-sectional areas of the aortic vessel. The new methods were applied in 10 eight-month-old mice (4 C57BL/6J-mice and 6 ApoE\(^{(-/-)}\)-mice) at 12 adjacent locations along the abdominal aorta.
Results:
Accelerated data acquisition and semi-automatic post-processing delivered reliable measures for the local PWV, similiar to those obtained with full data sampling and manual segmentation. No statistically significant differences of the mean values could be detected for the different measurement approaches. Mean PWV values were elevated for the ApoE\(^{(-/-)}\)-group compared to the C57BL/6J-group (3.5 ± 0.7 m/s vs. 2.2 ± 0.4 m/s, p < 0.01). A more heterogeneous PWV-distribution in the ApoE \(^{(-/-)}\)-animals could be observed compared to the C57BL/6J-mice, representing the local character of lesion development in atherosclerosis.
Conclusion:
In the present work, we showed that k-t BLAST PC-MRI enables the measurement of the local PWV distribution in the mouse aorta. The semi-automatic segmentation method based on PC-CMR data allowed rapid determination of local PWV. The findings of this study demonstrate the ability of the proposed methods to non-invasively quantify the spatial variations in local PWV along the aorta of ApoE\(^{(-/-)}\)-mice as a relevant model of atherosclerosis.
Contrast and non-contrast MRI based characterization of myocardium by T1-mapping will be of paramount importance to obtain biomarkers, e.g. fibrosis, which determines the risk of heart failure patients.
T1-mapping by the standard post-processing of the modified look-locker inversion recovery (MOLLI) lacks of accuracy when trying to reduce its duration, which on the other hand, is highly desirable in patients with heart failure. The recently suggested inversion group fitting (IGF) technique, which considers more parameters for fitting, has a superior accuracy for long T1 times despite a shorter duration. However, for short T1 values, the standard method has a superior precision. A conditional fitting routine is proposed which ideally takes advantage of both algorithms.
Materials and methods
All measurements were performed on a 1.5 T clinical scanner (ACHIEVA, Philips Healthcare, The Netherlands) using a MOLLI 5(n)3(n)3 prototype with n(heart beats) being a variable waiting time between inversion experiments. Phantom experiments covered a broad range of T1 times, waiting times and heart rates. A saturation recovery experiment served as a gold standard for T1 measurement. All data were analyzed with the standard MOLLI, the IGF fit and the conditional fitting routine and the obtained T1 values were compared with the gold standard. In vivo measurements were performed in a healthy volunteer and a total of 34 patients with normal findings, dilative cardiomyopathy and amyloidosis.
Results
Theoretical analysis and phantom experiments provided a threshold value for an apparent IGF
determining processing with IGF post processing for values above, or switching to the standard technique for values below. This was validated in phantoms and patients measurements. A reduction of the waiting time to 1 instead of 3 heart beats between the inversion experiments showed reliable results. The acquisition time was reduced from 17 to 13 heart beats. The in vivo measurements showed ECV values between 25% (18–33%; SD 0.03) in the healthy, 30% (22–40%; SD 0.04) in patients with DCM and 45% (30–60%; SD 0.9) in patients with amyloidosis.
Conclusion
The adopted post-processing algorithm determines long T1 values with high accuracy and short T1 values while maintaining a high precision. Based on reduction of waiting time, and independence of heart rate, it shortens breath hold duration and allows fast T1-mapping, which is frequently a prerequisite in patients with cardiac diseases.