Refine
Has Fulltext
- yes (22)
Is part of the Bibliography
- yes (22)
Year of publication
Document Type
- Doctoral Thesis (22)
Keywords
- Kernspintomografie (8)
- MRI (5)
- Bildgebendes Verfahren (4)
- Kernspintomographie (4)
- MRT (4)
- Magnetresonanztomographie (4)
- Compressed Sensing (3)
- Lunge (3)
- Bildrekonstruktion (2)
- Cardiac (2)
Institute
- Graduate School of Life Sciences (13)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (6)
- Deutsches Zentrum für Herzinsuffizienz (DZHI) (2)
- Klinik und Poliklinik für Nuklearmedizin (2)
- Physikalisches Institut (2)
- Graduate School of Science and Technology (1)
- Institut für Klinische Epidemiologie und Biometrie (1)
- Institut für Mathematik (1)
- Klinik und Poliklinik für Unfall-, Hand-, Plastische und Wiederherstellungschirurgie (Chirurgische Klinik II) (1)
- Medizinische Fakultät (1)
Sonstige beteiligte Institutionen
In this work, accelerated non-Cartesian Magnetic Resonance Imaging (MRI) methods were established and applied to cardiovascular imaging (CMR) at different magnetic field strengths (3T and 7T).
To enable rapid data acquisition, highly efficient spiral k-space trajectories were created. In addition, hybrid sampling patterns such as the twisting radial lines (TWIRL) k-space trajectory were studied.
Imperfections of the dynamic gradient system of a MR scanner result in k-space sampling errors. Ultimately, these errors can lead to image artifacts in non-Cartesian acquisitions.
Among other reasons such as an increased reconstruction complexity, they cause the lack of spiral sequences in clinical routine compared to standard Cartesian imaging.
Therefore, the Gradient System Transfer Functions (GSTFs) of both scanners were determined and used for k-space trajectory correction in post-correction as well as in terms of a pre-emphasis.
The GSTF pre-emphasis was implemented as a fully automatic procedure, which enabled a precise correction of arbitrary gradient waveforms for double-oblique slice orientations.
Consequently, artifacts due to trajectory errors could be mitigated, which resulted in high image quality in non-Cartesian MRI.
Additionally, the GSTF correction was validated by measuring pre-emphasized spiral gradient outputs, which showed high agreement with the theoretical gradient waveforms.
Furthermore, it could be demonstrated that the performance of the GSTF correction is superior to a simple delay compensation approach.
The developed pulse sequences were applied to gated as well as real-time CMR. Special focus lied on the implementation of a spiral imaging protocol to resolve the beating heart of animals and humans in real time and free breathing.
In order to achieve real-time CMR with high spatiotemporal resolution, k-space undersampling was performed. For this reason, efficient sampling strategies were developed with the aim to facilitate compressed sensing (CS) during image reconstruction.
The applied CS approach successfully removed aliasing artifacts and yielded high-resolution cardiac image series. Image reconstruction was performed offline in all cases such that the images were not available immediately after acquisition at the scanner.
Spiral real-time CMR could be performed in free breathing, which led to an acquisition time of less than 1 minute for a whole short-axis stack.
At 3T, the results were compared to the gold standard of electrocardiogram-gated Cartesian CMR in breath hold, which revealed similar values for important cardiovascular functional and volumetric parameters.
This paves the way to an application of the developed framework in clinical routine of CMR.
In addition, the spiral real-time protocol was transferred to swallowing and speech imaging at 3T, and first images were presented.
The results were of high quality and confirm the straightforward utilization of the spiral sequence in other fields of MRI.
In general, the GSTF correction yielded high-quality images at both field strengths, 3T and 7T.
Off-resonance related blurring was mitigated by applying non-Cartesian readout gradients of short duration. At 7T, however, B1-inhomogeneity led to image artifacts in some cases.
All in all, this work demonstrated great advances in accelerating the MRI process by combining efficient, undersampled non-Cartesian k-space coverage with CS reconstruction.
Trajectory correction using the GSTF can be implemented at any scanner model and enables non-Cartesian imaging with high image quality.
Especially MRI of dynamic processes greatly benefits from the presented rapid imaging approaches.
In den letzten Jahren hat die myokardiale MR-Perfusionsbildgebung als nichtinvasives Verfahren zur Darstellung von funktionellen Veränderungen des Myokards für die Diagnostik der KHK zunehmend an Bedeutung gewonnen. Während in den letzten 20 Jahren die kardiale MRT überwiegend bei einer Magnetfeldstärke von 1,5 T durchge-führt wurde und dies auch immer noch wird, findet aktuell eine rasante Verbreitung von MR-Systemen höherer Feldstärken statt. Von der neuen Hochfeldtechnik erhofft man sich vor allem, je nach Anwendung, eine deutliche Verbesserung der Bildqualität mit höherer räumlicher und zeitlicher Auflösung, wodurch der diagnostische Nutzen noch weiter gesteigert werden könnte.
In der vorliegenden Arbeit wurden mittels First-Pass-MR-Bildgebung bei einer Magnet-feldstärke von 3 T quantitative Werte für die myokardiale Perfusion von 20 gesunden Probanden unter Ruhebedingungen bestimmt.
Sowohl die erhobenen absoluten Perfusionswerte (0,859 ml/g/min im Mittel) als auch die Standardabweichung des mittleren MBF (0,298 ml/g/min) entsprechen den Messungen aus den früheren Publikationen dieser Arbeitsgruppe. In der Gesamtzusammenschau bisher veröffentlichter Perfusionsstudien zeigt sich eine relativ große Variabilität der publizierten Ruheflüsse. Dabei liegt der absolute MBF dieser Arbeit im mittleren Wertebereich dieser Streubreite. Er lässt sich auch mit den in PET-Studien ermittelten Ergebnissen in Einklang bringen, welche als Goldstandard zur Bestimmung der absoluten myokardialen Perfusion beim Menschen gelten.
Die vorliegende Arbeit bestätigt die bereits in anderen 3 T-Studien untersuchten Vorteile der Hochfeld-MRT. Die höhere Magnetfeldstärke ermöglicht durch das größere SNR eine signifikant bessere räumliche Auflösung und besticht vor allem durch die hohe Bildqualität. Dies könnte bei der Erkennung kleiner, subendokardial gelegener Perfusionsdefekte sowie der Erstellung von transmuralen Perfusionsgradienten von Bedeutung sein und verspricht neben einer Reduktion von Partialvolumeneffekten auch eine Verminderung von „dark rim“-Artefakten.
Um diese Vorteile entsprechend nutzen zu können, wird die Entwicklung von Methoden zur pixelweisen Bestimmung der absoluten Flüsse und farblich kodierten Darstellung derselben in Form von Perfusionskarten ein weiterer Schritt in Richtung klinisch einsetzbare Diagnostik sein. Eine Voraussetzung hierfür ist die Entwicklung einer exakten und sehr stabilen Bewegungskorrektur in weiterführenden Studien.
Durch den Wechsel zu einer höheren Magnetfeldstärke von 3 T und den sich daraus ergebenden Vorteilen kann das Potential der MR-Perfusionsbildgebung, insbesondere der Bestimmung quantitativer Perfusionswerte, im Bereich der nichtinvasiven KHK-Diagnostik zukünftig weiter gesteigert werden.
Patienten mit chronischen Lungenerkrankungen leiden unter schwerwiegender Symptomatik und bedürfen regelmäßiger Verlaufskontrollen der Therapie. Dabei sollte zum Schutz der Patienten sowohl auf kanzerogene, ionisierende Strahlung verzichtet als auch der Einsatz potenziell nebenwirkungsreicher Kontrastmittel vermieden werden. Die pulmonale Blutflussgeschwindigkeit im Parenchym stellt einen quantitativen, bildgebenden Biomarker dar, mit dessen Hilfe die Dynamik des Krankheitsgeschehens untersucht werden kann. In dieser Arbeit wurde eine neue Auswertungsmethode vorgestellt, die mit Hilfe kontrastmittelfreier Magnetresonanztomographie die Blutflussgeschwindigkeit im Lungenparenchym quantifizieren kann. Die auf diese Weise bestimmten Ergebnisse entsprechen den Angaben zur Lungenperfusion, wie sie in der Literatur zu finden sind.
Die vorliegende Arbeit untersucht den Natriumgehalt verschiedener Kompartimente des Körpers mittels Magnetresonanztomographie (= MRT).
Die Korrelation zwischen erhöhtem Salzkonsum und arterieller Hypertonie ist bereits umfangreich analysiert worden. Für das Verständnis der pathophysiologischen Zustände und deren Regulation, ist eine Quantifizierung von Natriumkonzentrationen in verschiedenen Gewebearten bedeutsam. Die exakte Messung von Natriumkonzentrationen im menschlichen Gewebe ist derzeit experimentell. Im Rahmen der hier vorgelegten Arbeit wurden die Natriumkonzentrationen von Haut und Skelettmuskel mittels 23Na Magnetresonanztomographie (= 23 Na MRT) im menschlichen Körper quantifiziert.
Natriummessungen wurden bei Patienten mit primärem Hyperaldosteronismus (= PHA), bei Patienten mit essentieller Hypertonie (= EH), sowie einer gesunden Kontrollgruppe vorgenommen.
Die Ergebnisse zeigten, dass Haut und Skelettmuskel Speicherorgane für Natrium im menschlichen Körper darstellen. Durch gezielte Therapie waren die Natriumkonzentrationen in beiden Speicherorganen modulierbar
Diffusionsgewichtete MR-Bilder sind ein wichtiger Bestandteil für die klinische Diagnostik
verschiedener Pathologien, wie z.B. bei Schlaganfall oder Tumoren. Meistens
wird ein mono-exponentielles Diffusionsmodell verwendet und über verschiedene
Raumrichtungen gemittelt. Der Einfluss von Fluss auf das diffusionsgewichtete
Signal und eine mögliche Richtungsabhängigkeit werden dabei vernachlässigt. Dabei
machen Diffusionsmodelle, die mehr Eigenschaften des Signals abbilden, unter
Umständen eine genauere Diagnostik möglich. Mit DTI wird die Richtungsabhängigkeit
der Diffusion erfasst und bei IVIM wird der Beitrag von Fluss zum Signal
berücksichtigt. Die Niere ist ein stark strukturiertes Organ und weist Anisotropie
in der Diffusion auf. Außerdem ist die Niere ein sehr gut durchblutetes Organ. DTI
und IVIM beschreiben also unabhängig voneinander zwei wichtige Aspekte des diffusionsgewichteten
Signals in der Niere, ohne dass der Vorteil des jeweils anderen
Modells Beachtung findet.
In dieser Arbeit wurde das Modell IVOF zur umfassenden Beschreibung von Diffusionssignal
vorgestellt, bei dem sowohl die Richtungsabhängigkeit der Diffusion,
als auch das Signal der fließenden Spins und deren Richtungsabhängigkeit abgebildet
wird. Die Vorteile von DTI und IVIM werden also in IVOF vereint und darüber
hinaus auch die mögliche Anisotropie die Flusssignals berücksichtigt. Es konnte gezeigt
werden, dass dieses Modell das diffusionsgewichtete Signal in der menschlichen
Niere besser beschreibt als die herkömmlichen Modelle (DTI und IVIM) und auch
besser als eine Kombination von DTI und IVIM, bei der ein isotroper Flussanteil
des Signals angenommen wird.
Es wurde weiterhin gezeigt, dass selbst wenn der Flussanteil im verwendeten Diffusionsmodell
berücksichtigt wird, der tatsächlich gemessene Flussanteil in der Niere
von der Art der Messung, d.h. Bewegungsempfindlichkeit des Gradientenschemas
abhängt. Das bedeutet, dass der mikroskopische Fluss in der Niere nicht, wie häufig
angenommen, komplett zeitlich inkohärent ist. Bei Vergleichen von IVIM Studien
an der Niere ist es deshalb notwendig, die Bewegungsempfindlichkeit der jeweiligen
Gradientenschemata zu berücksichtigen. Wie groß das absolute Verhältnis von kohärent zu inkohärent fließendem Signal ist, konnte nicht festgestellt werden. Ebenso
wenig konnte die absolute Flussgeschwindigkeit bzw. die Art des Flusses (Laminare
Strömung, Pfropfenströmung, oder andere) ermittelt werden.
TSE hat sich als vielversprechendes, artefaktfreies Verfahren für die Aufnahme
diffusionsgewichteter Bilder der Niere gezeigt. Im Vergleich mit dem Standardverfahren EPI wurden ähnliche Werte der Parameter von DTI und IVIM gefunden.
Abweichungen zwischen EPI und TSE sind vor allem durch die Unschärfe der TSE
Bilder aufgrund von T2-Zerfall zu erklären. Bis zur klinischen Anwendbarkeit diffusionsgewichteter
TSE Bilder bzw. Parameterkarten sind noch einige Weiterentwicklungen
der Methode nötig. Vor allem sind schärfere TSE Bilder erstrebenswert und
es sollten mehrere Schichten in einer klinisch vertretbaren Zeitspanne aufgenommen
werden, ohne dass dabei die zulässigen SAR Grenzwerte überschritten werden.
Bei allen Untersuchungen in dieser Arbeit handelt es sich um Machbarkeitsstudien.
Daher wurden alle Messungen nur an erwachsenen, gesunden Probanden durchgeführt, um zu zeigen, dass das jeweilige vorgeschlagene Modell zu den Daten passt
bzw. dass die vorgeschlagene Methode prinzipiell funktioniert. Bei welchen Pathologien
die hier vorgeschlagenen Methoden und Modelle einen diagnostischen Nutzen
haben, muss in zukünftigen Studien erforscht werden. Außerdem wurden keine b-
Werte zwischen 0 und 200 s/mm2 aufgenommen, bei denen fließende Spins noch
signifikant zum Signal beitragen. Betrachtet man die Ergebnisse der Diffusionsbildgebung
mit verschiedenen m1 in dieser Arbeit, dann ist neben dem b-Wert auch die
Bewegungsempfindlichkeit m1 nötig, um das Signal in diesem Bereich korrekt zu
beschreiben.
Alles in allem sollte der Beitrag von Fluss zum diffusionsgewichteten MR-Signal
in der Niere immer berücksichtigt werden. Die vielfältigen Einflüsse, die unterschiedliche
Parameter auf das Signal von Mikrofluss haben, wurden in dieser Arbeit untersucht
und präsentieren weiterhin ein spannendes Feld für kommende Studien.
Diffusionsgewichtete TSE Sequenzen sind auch für die klinische Diagnostik eine potentielle
Alternative zu Artefakt-anfälligen EPI Sequenzen. Bis dahin sollten jedoch
die Bildschärfe und Abdeckung der diffusionsgewichteten TSE Sequenz weiter verbessert
werden.
Cardiovascular disease is one of the leading causes of death worldwide and, so far, echocardiography, nuclear cardiology, and catheterization are the gold standard techniques used for its detection. Cardiac magnetic resonance (CMR) can replace the invasive imaging modalities and provide a "one-stop shop" characterization of the cardiovascular system by measuring myocardial tissue structure, function and perfusion of the heart, as well as anatomy of and flow in the coronary arteries. In contrast to standard clinical magnetic resonance imaging (MRI) scanners, which are often operated at a field strength of 1.5 or 3 Tesla (T), a higher resolution and subsequent cardiac parameter quantification could potentially be achieved at ultra-high field, i.e., 7 T and above.
Unique insights into the pathophysiology of the heart are expected from ultra-high field MRI, which offers enhanced image quality in combination with novel contrast mechanisms, but suffers from spatio-temporal B0 magnetic field variations. Due to the resulting spatial misregistration and intra-voxel dephasing, these B0-field inhomogeneities generate a variety of undesired image artifacts, e.g., artificial image deformation. The resulting macroscopic field gradients lead to signal loss, because the effective transverse relaxation time T2* is shortened. This affects the accuracy of T2* measurements, which are essential for myocardial tissue characterization. When steady state free precession-based pulse sequences are employed for image acquisition, certain off-resonance frequencies cause signal voids. These banding artifacts complicate the proper marking of the myocardium and, subsequently, systematic errors in cardiac function measurements are inevitable. Clinical MR scanners are equipped with basic shim systems to correct for occurring B0-field inhomogeneities and resulting image artifacts, however, these are not sufficient for the advanced measurement techniques employed for ultra-high field MRI of the heart.
Therefore, this work focused on the development of advanced B0 shimming strategies for CMR imaging applications to correct the spatio-temporal B0 field variations present in the human heart at 7 T. A novel cardiac phase-specific shimming (CPSS) technique was set up, which featured a triggered B0 map acquisition, anatomy-matched selection of the shim-region-of-interest (SROI), and calibration-based B0 field modeling. The influence of technical limitations on the overall spherical harmonics (SH) shim was analyzed. Moreover, benefits as well as pitfalls of dynamic shimming were debated in this study. An advanced B0 shimming strategy was set up and applied in vivo, which was the first implementation of a heart-specific shimming approach in human UHF MRI at the time.
The spatial B0-field patterns which were measured in the heart throughout this study contained localized spots of strong inhomogeneities. They fluctuated over the cardiac cycle in both size and strength, and were ideally addressed using anatomy-matched SROIs. Creating a correcting magnetic field with one shim coil, however, generated eddy currents in the surrounding conducting structures and a resulting additional, unintended magnetic field. Taking these shim-to-shim interactions into account via calibration, it was demonstrated for the first time that the non-standard 3rd-order SH terms enhanced B0-field homogeneity in the human heart. However, they were attended by challenges for the shim system hardware employed in the presented work, which was indicated by the currents required to generate the optimal 3rd-order SH terms exceeding the dynamic range of the corresponding shim coils. To facilitate dynamic shimming updated over the cardiac cycle for cine imaging, the benefit of adjusting the oscillating CPSS currents was found to be vital. The first in vivo application of the novel advanced B0 shimming strategy mostly matched the simulations.
The presented technical developments are a basic requirement to quantitative and functional CMR imaging of the human heart at 7 T. They pave the way for numerous clinical studies about cardiac diseases, and continuative research on dedicated cardiac B0 shimming, e.g., adapted passive shimming and multi-coil technologies.
SPECT as a representative of molecular imaging allows visualization of metabolic processes in vivo. In clinical practice, single photon emission imaging is an established modality for myocardial perfusion imaging or the diagnosis of adrenal or neuroendocrine tumors, to name a few. With technical advances in scanner design and data processing leading to improved spatial resolution and image quality, SPECT has become a serious contender in small animal preclinical imaging. With multi-pinhole collimation, submillimeter spatial resolutions are achieved without limiting sensitivity, which has led to a significant increase of interest in SPECT for preclinical research in recent years.
In this dissertation, the potential of a two-detector system through an analysis of three dedicated mouse collimators with multi-pinhole configurations was demonstrated. For this, sensitivity, spatial resolution, and uniformity as key parameters were determined. In the second part of the present work, an evaluation of the image quality at different activity concentrations to allow prediction of the system performance related to in vivo studies was performed. Therefore, a visual evaluation, as well as a calculation of the contrastto-noise ratio, was performed using mini Derenzo phantoms for the respective three mouse collimators. To better classify the results, the study was extended by a comparison with the predecessor system.
Due to the absence of the third bottom detector, sensitivity and uniformity are slightly compromised. All three collimators were able to achieve a spatial resolution in the submillimeter range, XUHR-M offers a peak resolution of up to 0.35 mm. In terms of resolution, both evaluated systems performed on an equal level. Visual assessment of image quality indicates a slight advantage of the new two-detector system, and the contrast-to-noise ratio seems to benefit from the improved SROSEM algorithm. However, the differences between the two systems are marginal.
The U-SPECT5/CT E-Class is proven to be state-of-the-art for small animal imaging and is a powerful instrument for preclinical molecular imaging research. Improvements in system design compensate well for the reduction in the detection area, allowing excellent imaging even with low activity concentrations.
Die Magnetresonanztomographie stellt den Goldstandard zur kardialen Funktionsdiagnostik dar und ermöglicht die nicht-invasive Analyse der Herzfunktion mit valider Bestimmung von Volumina, Flüssen sowie der Ejektionsfraktion in vivo. In unserer Arbeitsgruppe erfolgt eine stetige Weiterentwicklung der Methode am Rattenmodell, wobei regelhaft eine Narkose des Versuchtstiers notwendig ist. Im Rahmen meiner Arbeit wurde der Effekt verschiedener Narkoseformen auf die Herzfunktion untersucht. Dabei wurde eine Isoflurannarkose einer Narkose mittels Propofol sowie Propofol in Kombination mit Pancuronium gegenübergestellt. Hierbei zeigen sich teilweise deutliche Unterschiede in den kardialen Funktionsparametern während der Untersuchung. Hieraus ist zu folgern, dass ein sinnvoller Vergleich der Herzfunktion von Versuchsreihen mit unterschiedlicher Narkosetechnik problematisch ist. Dies unterstreicht die Wichtigkeit einer Festlegung der Narkosetechnik vor Beginn einer Versuchsreihe in der kardiovaskulären Forschung und deren Konstanthaltung über die gesamte Versuchsdauer.
Molecular imaging of rats is of great importance for basic and translational research. As a powerful tool in nuclear medicine, SPECT can be used to visualize specific functional processes in the body, such as myocardial perfusion or bone metabolism. Typical applications in laboratory animals are imaging diagnostics or the development of new tracers for clinical use. Innovations have enabled resolutions of up to a quarter of a millimeter with acceptable sensitivity. These advances have recently led to significantly more interest in SPECT both clinically and preclinically.
The objective of this thesis was to evaluate the performance of the new U-SPECT5/CT E-Class by MILabs with a dedicated ultra-high resolution multi-pinhole collimator for rats and its potential for in vivo imaging of rats. The unique features of the U-SPECT are the large stationary detectors and the new iterative reconstruction algorithm. In addition, compared to the conventional system, the "E-Class" uses only two detectors instead of three.
First, the sensitivity, maximum resolution, and uniformity were determined as performance parameters. Thereafter, CNRs for different activity levels comparable to those of typical in vivo activities were examined. Finally, two example protocols were carried out for imaging with 99mTc-MIBI and 99mTc-HMDP in healthy rats to evaluate the in vivo capabilities. For this purpose, CNR calculations and an image quality assessment were performed. The focus was on image quality as a function of scan time and post-reconstruction filter across a wide range of realistically achievable in vivo conditions.
Performance was reasonable compared to other systems in the literature, with a sensitivity of 567 cps/MBq, a maximum resolution of 1.20 mm, and a uniformity of 55.5%. At the lower activities, resolution in phantom studies decreased to ≥1.80 mm while maintaining good image quality. High-quality bone and myocardial perfusion SPECTs were obtained in rats with a resolution of ≥1.80 mm and ≥2.20 mm, respectively. Although limited sensitivity remains a weakness of SPECT, the U-SPECT5/CT E-Class with the UHR-RM collimator can achieve in vivo results of the highest standard despite the missing third detector. Currently, it is one of the best options for high-resolution radionuclide imaging in rats.
Seit Mitte der 1990er Jahre wurden nationale und regionale Schlaganfallregister in Europa etabliert, die Auskunft über die Versorgungsqualität von Schlaganfallpatienten geben. Bislang lagen nur wenige Daten zu zeitlichen Trends der akuten Schlaganfallversorgung vor. Diese sind jedoch essentiell, um beispielsweise Zusammenhänge zwischen der Einführung potentiell qualitätsverbessernder Maßnahmen und der Entwicklung der Versorgungsqualität feststellen zu können. Die Behandlung von Schlaganfallpatienten auf Stroke Units ist aufgrund der eindeutigen Evidenz aus randomisierten- und Beobachtungsstudien zum Standard geworden. Bislang war unklar, ob demografische und klinische Charakteristika die direkte Aufnahme auf eine Stroke Unit beeinflussen. Zudem war nicht bekannt, ob und wenn ja, in welchem Ausmaß strukturelle Kriterien und der Anteil der Patienten, der auf eine Stroke Unit aufgenommen wurde, die Qualität der Stroke Unit Versorgung beeinflussen. Im Anschluss an die Akutbehandlung im Krankenhaus bzw. nach geeigneten Rehabilitationsmaßnahmen übernehmen pflegende Angehörige häufig die Versorgung der Schlaganfallpatienten im häuslichen Umfeld. Die aktuelle Situation der pflegenden Angehörigen von Schlaganfallpatienten in Deutschland ist bisher jedoch nur unzureichend evaluiert.
In der vorliegenden Dissertation wurden zunächst im Rahmen des „European Implementation Score“-Projektes zeitliche Trends der Qualität der akuten Schlaganfallversorgung in fünf nationalen europäischen Schlaganfallregistern aus Deutschland, England/Wales/Nordirland, Polen, Schottland und Schweden nach zuvor definierten evidenzbasierten Qualitätsindikatoren berechnet. Im zweiten Schritt wurde anhand von Daten der Arbeitsgemeinschaft Deutscher Schlaganfall Register (ADSR) evaluiert, ob demografische und klinische Patientencharakteristika die direkte Aufnahme auf eine Stroke Unit in Deutschland beeinflussen. Weiterhin wurde der Einfluss struktureller Charakteristika auf die Erfüllung von 11 evidenzbasierter Qualitätsindikatoren in Krankenhäusern, die über eine regionale oder überregionale Stroke Unit verfügen, untersucht. Abschließend wurden im Rahmen des regionalen Telemedizinnetzwerkes TRANSIT-Stroke demografische und klinische Charakteristika von Schlaganfallpatienten, die 3 Monate nach dem Schlaganfall mit dem Erhalt von Pflege durch einen Angehörigen assoziiert waren, identifiziert. Zusätzlich wurden mit standardisierten Erhebungsinstrumenten positive und negative Erfahrungen der Pflege eines Schlaganfallpatienten sowie die selbsteingeschätzte Belastung (deutsche Version des Caregiver Reaction Assessment und Self-Rated Burden Scale) ausgewertet sowie Faktoren, die mit den Pflegeerfahrungen und Belastungen assoziiert sind, evaluiert.
Auf europäischer Ebene konnten wir einen Zusammenhang zwischen der Einführung eines neuen Qualitätsindikators und der Verbesserung der Qualität beobachten. Dies galt insbesondere für die erstmalige Einführung des Qualitätsindikators Dysphagiescreening im deutschen -(2006) und schwedischen Schlaganfallregister (2007). Somit gibt es Hinweise darauf, dass das Monitoring der Qualität der Schlaganfallversorgung zu Qualitätsverbesserungen bzw. auch zu einer vollständigeren Dokumentation führt.
Insgesamt konnten wir ein qualitativ hohes Niveau der akuten Schlaganfallversorgung auf Stroke Units in Deutschland gemäß evidenzbasierter Qualitätsindikatoren feststellen. Patienten mit einem ischämischen Schlaganfall, die am Wochenende aufgenommen wurden (p<0,0001), innerhalb von 3 Stunden nach Symptombeginn im Krankenhaus aufgenommen wurden (p<0,0001), hypertensiv waren (p<0,0001), unter einer Hyperlipidämie (p<0,0001) litten, wurden mit einer höheren Wahrscheinlichkeit auf einer Stroke Unit aufgenommen. Dagegen hatten Patienten mit einem schwereren Schlaganfall (NIHSS>15) eine geringere Chance, auf einer Stroke Unit aufgenommen zu werden (p<0,0001). Der Einfluss struktureller Charakteristika auf die Qualität der Stroke Unit Versorgung war gering. Eine Verbesserung der Qualität könnte noch durch einen höheren Anteil der auf einer Stroke Unit aufgenommenen Patienten erreicht werden.
Im Rahmen der Nachbefragung von Patienten im regionalen Telemedizinnetzwerk TRANSIT-Stroke stellten Frauen mit 70,1% den größten Anteil der pflegenden Angehörigen dar. 74,4% der pflegenden Angehörigen war älter als 55 Jahre. In univariablen und multivariablen logistischen Regressionsanalysen waren ein hohes Alter, ein niedriger Barthel-Index bei Entlassung sowie das Vorliegen von Diabetes signifikant mit einer höheren Wahrscheinlichkeit assoziiert, Pflege von einem Angehörigen zu erhalten. Der Großteil der pflegenden Angehörigen möchte den Angehörigen pflegen und ist gleichzeitig dem Risiko gesundheitlicher Probleme ausgesetzt. Circa ein Fünftel der pflegenden Angehörigen berichtete finanzielle Belastungen aufgrund der Pflegesituation. Depressive Symptome der Patienten waren mit einer höheren Belastung der pflegenden Angehörigen hinsichtlich der selbsteingeschätzten Belastung und den positiven und negativen Erfahrungen assoziiert. Jüngere, männliche Schlaganfallpatienten, mit einem milderen Schlaganfall, die mit einer Partnerin oder Ehepartnerin zusammenleben, scheinen sich oft nicht bewusst zu sein, dass sie Pflege erhalten. Möglich ist hier, dass sie die Unterstützung und Pflege als „normal“ betrachten, während der Partner bzw. die Partnerin dies als tatsächliche Pflege wertet.
Schlaganfallregister eignen sich, um die Qualität der Akutversorgung im Zeitverlauf zu monitorieren und Zusammenhänge zwischen der Einführung potentiell qualitätsverbessernder Maßnahmen und der tatsächlichen Qualität darstellen zu können. Die Qualität der Stroke Unit Versorgung in Deutschland ist auf einem hohen Niveau. Eine Verbesserung der Qualität könnte noch durch einen höheren Anteil der auf einer Stroke Unit aufgenommenen Patienten erreicht werden. Ein Großteil der Schlaganfallpatienten lebt im Anschluss an die Akutversorgung im häuslichen Umfeld, in dem pflegende Angehörige eine wichtige Rolle bei der Versorgung spielen. Pflegenden Angehörigen ist ihre Aufgabe wichtig, sind jedoch aufgrund der Pflege zugleich Belastungen hinsichtlich ihrer Gesundheit, der Gestaltung ihres täglichen Zeitplans und der Finanzen ausgesetzt.