Refine
Has Fulltext
- yes (21)
Is part of the Bibliography
- yes (21)
Year of publication
Document Type
- Doctoral Thesis (21)
Keywords
- Kernspintomografie (6)
- Kernspintomographie (3)
- Arteriosklerose (2)
- Atherosclerosis (2)
- Herzinsuffizienz (2)
- MRI (2)
- Maus (2)
- 3D-Bildgebung (1)
- 7 T (1)
- 7T (1)
- AI (1)
- Alignment <Biochemie> (1)
- Aorta (1)
- Artery Models (1)
- Atherosklerose (1)
- Awareness (1)
- B0 (1)
- Bildgebendes Verfahren (1)
- Biofabrication (1)
- CD68 (1)
- Cardiac (1)
- Cardiac Efficiency (1)
- Cardiac MRI (1)
- Chemischer Austausch (1)
- Chronische Nierenerkrankung (1)
- Chronische Niereninsuffizienz (1)
- Cyclo-AMP (1)
- DTI (1)
- Diffusionsgewichtete Magnetresonanztomografie (1)
- Echocardiography (1)
- Echokardiographie (1)
- Elastin (1)
- Entzündung (1)
- Extrazellularvolumen (1)
- FAIR-ASL (1)
- Feature-Selection (1)
- Fisher-Score (1)
- Flussbildgebung (1)
- Heart Failure (1)
- Hemodynamics (1)
- Herzbildgebung (1)
- Herzmuskel (1)
- Herzmuskelzelle (1)
- Herzschlag (1)
- Hidden-Markov-Modell (1)
- Hypertension (1)
- Hämodynamik (1)
- Implantierbarer Kardioverter-Defibrillator (1)
- Inflammation (1)
- Inversion Recovery (1)
- Kardiale Phasenkontrast-MRT (1)
- Kardiovaskuläres System (1)
- Kernspinresonanz (1)
- Kollagen (1)
- Koronare Herzkrankheit (1)
- Kreuzvalidierung (1)
- Künstliche Intelligenz (1)
- LV Function (1)
- Lung (1)
- Lunge (1)
- MOLLI (1)
- MRT (1)
- Macrophage (1)
- Magnetresonanztomographie (1)
- Makrophage (1)
- Makrophagen (1)
- Modellbasierte Rekonstruktion (1)
- Myocardial Work (1)
- Myokardiale Deformation (1)
- Myokardiale Perfusion (1)
- Myokardinfarkt (1)
- Na+/K+-ATPase (1)
- Natrium-Kalium-Pumpe (1)
- Niere (1)
- Non-invasive imaging (1)
- Nuclear imaging (1)
- PDE (1)
- PET (1)
- Perfusion (1)
- Perfusionsmessung (1)
- Phosphodiesterase (1)
- Physioloische MRT (1)
- Positron emission tomography (1)
- Positronen-Emissions-Tomographie (1)
- Pulswellengeschwindigkeit (1)
- PyMOL (1)
- Regionales Blutvolumen (1)
- Regularisierung (1)
- Relaxation (1)
- Relaxationszeit (1)
- Relaxographie (1)
- Relaxography (1)
- Relaxometrie (1)
- Relaxometry (1)
- SH3-Domäne (1)
- STAAB Cohort Study (1)
- STAAB study (1)
- STAAB-Studie (1)
- Sekundärprävention (1)
- Selbstnavigation (1)
- Shimming (1)
- Speckle Tracking (1)
- Spin-Gitter-Relaxation (1)
- Steady-State Sequences (1)
- Steady-State-Sequenzen (1)
- Support-Vektor-Maschine (1)
- T1 (1)
- T1 Relaxation (1)
- T1-Quantifizierung (1)
- Taxonomie (1)
- Tissue Engineering (1)
- Transthorakale Echokardiographie (1)
- UTE (1)
- Ultrahigh field (1)
- Ultrahochfeldmagnetresonanztomographie (1)
- Vorhofflimmern (1)
- Vulnerable plaque (1)
- Wandschubspannung (1)
- Wasted Work (1)
- WebLogo (1)
- balanced SSFP (1)
- cAMP (1)
- chronic kidney disease (1)
- coronary heart disease (1)
- e1071 (1)
- heart failure (1)
- koronare Herzerkrankung (1)
- myocardial deformation (1)
- myocardial infarction (1)
- myokardiale Arbeit (1)
- secondary prevention (1)
- speckle tracking (1)
- strain (1)
- strain rate (1)
- ultra highfield magnetic resonance imaging (1)
- wall shear stress (1)
Institute
- Graduate School of Life Sciences (10)
- Physikalisches Institut (6)
- Deutsches Zentrum für Herzinsuffizienz (DZHI) (4)
- Medizinische Klinik und Poliklinik I (4)
- Institut für Klinische Epidemiologie und Biometrie (3)
- Graduate School of Science and Technology (2)
- Abteilung für Funktionswerkstoffe der Medizin und der Zahnheilkunde (1)
- Institut für Experimentelle Biomedizin (1)
- Institut für Pharmakologie und Toxikologie (1)
- Medizinische Fakultät (1)
Sonstige beteiligte Institutionen
- Universitätsklinikum Würzburg (3)
- Deutsches Zentrum für Herzinsuffizienz (1)
- Experimental Physics V, University of Wuerzburg (1)
- Fraunhofer Institut für Integrierte Schaltungen (IIS) (1)
- Institut für Medizintechnik Schweinfurt (IMeS) (1)
- Interdisziplinäre Zentrum für Klinische Forschung (IZKF) (1)
- Medizinische Klinik und Poliklinik 1, Abteilung Kardiologie (1)
- Medizinische Klinik und Poliklinik 1, Abteilung Nephrologie (1)
- Universitätsklinikum Würzburg (UKW) (1)
Ziel dieser Arbeit ist es, die quantitative MRT in den Fokus zu rücken. In den letzten Jahren hat sich auf diesem Forschungsgebiet viel weiterentwickelt und es wurden verschiedenste Sequenzen und Methoden vorgestellt, um insbesondere Relaxationszeitparameter quantitativ in kurzer Zeit zu messen. Steady-State-Sequenzen eignen sich besonders für diese Thematik, da sie kurze Messzeiten benötigen und darüber hinaus ein relativ hohes SNR besitzen. Speziell die IR TrueFISP-Sequenz bietet für die Parameterquantifizierung viel Potential. Ursprünglich wurde diese Sequenz an der Universität Würzburg zur simultanen Messung von T1- und T2-Relaxationszeiten vorgestellt und hinsichtlich der Zeiteffizienz weiterentwickelt. In dieser Arbeit wurde ein neuartiger iterativer Rekonstruktionsansatz für die IR TrueFISP-Sequenz entwickelt, der auf einer Hauptkomponentenanalyse (PCA) basiert und sich die glatten Signalverläufe zu Nutze macht. Aufgrund der hohen Zeitauflösung dieser Rekonstruktionstechnik werden dabei auch Gewebekomponenten mit kurzen Relaxationszeiten detektierbar. Weiterhin bewahrt der Rekonstruktionsansatz Informationen mehrerer Gewebekomponenten innerhalb eines Voxels und ermöglicht damit eine relaxographische Untersuchung. Insbesondere beim Menschen führen der Partialvolumeneffekt und die Mikrostruktur des Gewebes zu Signalverläufen, die ein multi-exponentielles Signal liefern. Die MR-Relaxographie, also die Darstellung von Relaxationszeitverteilungen innerhalb eines Voxels, stellt eine Möglichkeit dar, um die beteiligten Gewebekomponenten aus dem überlagerten Signalverlauf zu extrahieren. Insgesamt bilden die optimierte Relaxometrie mit der Möglichkeit der analytischen Korrektur von Magnetfeldinhomogenitäten und die beschleunigte Relaxographie die Hauptteile dieser Dissertation. Die Hauptkapitel werden im Folgenden noch einmal gesondert zusammengefasst.
Die simultane Aufnahme der quantitativen T1- und T2-Parameter-Karten kann mit einem
Goldenen-Winkel-basiertem radialen IR TrueFISP-Readout in ungefähr 7 Sekunden pro
Schicht erreicht werden. Die bisherige Rekonstruktionstechnik mit dem KWIC-Filter ist
durch dessen breite Filter-Bandbreite und somit in der zeitlichen Auflösung limitiert. Besonders bei hohen räumlichen Frequenzen wird eine sehr große Anzahl an Projektionen
zusammengefasst um ein Bild zu generieren. Dies sorgt dafür, dass Gewebekomponenten mit kurzer T1*-Relaxationszeit (z.B. Fett oder Myelin) nicht akkurat aufgelöst werden können. Um dieses Problem zu umgehen, wurde die T1* shuffling-Rekonstruktion entwickelt, die auf dem T2 Shuffling-Ansatz basiert. Diese Rekonstruktionstechnik macht sich die glatten Signalverläufe der IR TrueFISP-Sequenz zu Nutze und ermöglicht die Anwendung einer PCA. Die iterative Rekonstruktion sorgt dafür, dass mit nur acht kombinierten Projektionen pro generiertem Bild eine merklich verbesserte temporäre Auflösung erzielt werden kann. Ein Nachteil ist jedoch das stärkere Rauschen in den ersten Bildern der Zeitserie bedingt durch die angewandte PCA. Dieses verstärkte Rauschen äußert sich in den leicht erhöhten Standardabweichungen in den berechneten Parameter-Karten. Jedoch ist der Mittelwert näher an den Referenzwerten im Vergleich zu den Ergebnissen mit dem KWIC-Filter. Letztendlich kann man sagen, dass die Ergebnisse leicht verrauschter, aber exakter sind.
Mittels zusätzlichen Regularisierungstechniken oder Vorwissen bezüglich des Rauschlevels
wäre es zudem noch möglich, das SNR der ersten Bilder zu verbessern, um dadurch den
beschriebenen Effekt zu verringern.
Grundsätzlich hängt die Genauigkeit von IR TrueFISP vom T1/T2-Verhältnis des betreffenden
Gewebes und dem gewählten Flipwinkel ab. In dieser Arbeit wurde der Flipwinkel besonders für weiße und graue Masse im menschlichen Gehirn optimiert. Mit den verwendeten 35° wurde er außerdem etwas kleiner gewählt, um zudem Magnetisierungstransfereffekte zu minimieren. Mit diesen Einstellungen ist die Präzision vor allem für hohe T1- und niedrige T2-Werte sehr gut, wird jedoch insbesondere für höhere T2-Werte schlechter. Dies ist aber ein generelles Problem der IR TrueFISP-Sequenz und hängt nicht mit der entwickelten Rekonstruktionsmethode zusammen. Außerdem wurde im fünften Kapitel eine
Akquisitionstechnik vorgestellt, die eine 3D-Abdeckung der quantitativen Messungen des Gehirns in klinisch akzeptabler Zeit von unter 10 Minuten erzielt. Dies wird durch Einsatz der parallelen Bildgebung erreicht, da eine Kombination aus radialer Abtastung in der Schicht und kartesischer Aufnahme in Schichtrichtung (Stack-of-Stars) vorliegt.
Ein großes Problem in der Steady-State-Sequenz (und somit auch bei IR TrueFISP) sind
Magnetfeldinhomogenitäten, die durch Suszeptibilitätsunterschiede verschiedener Gewebe und/oder Inhomogenitäten des Hauptmagnetfeldes hervorgerufen werden. Diese führen zu Signalauslöschungen und damit verbunden zu den beschriebenen Banding-Artefakten. Mithilfe der analytisch ermittelten Korrekturformeln ist es nun möglich, die berechneten (T1,T2)-Wertepaare unter Berücksichtigung der tatsächlich auftretenden Off- Resonanzfrequenz für einen großen Bereich zu korrigieren. An den kritischen Stellen, an denen die Bandings auftreten, liefert jedoch auch diese Korrektur keine brauchbaren Ergebnisse. Grundsätzlich ist es für die Genauigkeit der Ergebnisse stets zu empfehlen, die Flipwinkel- und B0-Karte zusätzlich mit aufzunehmen, um diese Parameter für die quantitative Auswertung exakt zu kennen. Mit den beschriebenen Methoden aus Kapitel 6 könnte es prinzipiell auch möglich sein, die Off-Resonanzfrequenz aus dem Signalverlauf zu ermitteln und auf die zusätzliche Messung der B0-Karte zu verzichten. B0-Änderungen während der Messung, die von der Erwärmung der passiven Shim-Elemente im MR-System hervorgerufen werden, sind kaum zu korrigieren. Ein stabiler Scanner ohne B0-Drift ist deshalb für quantitative Auswertungen erforderlich.
Die erwähnte Messzeit von 7 Sekunden pro Schicht garantiert, dass auch Gewebe mit längeren Relaxationskomponenten annähernd im Steady-State sind, was wiederum für das Umkehren des Signals in den abklingenden Verlauf gegen Null und die anschließende
Multikomponentenanalyse (vgl. Kapitel 7) notwendig ist. Mit der inversen Laplace-
Transformation ist es innerhalb eines Voxels möglich, Signalverläufe auf mehrere Komponenten hin zu untersuchen. Der ursprünglich angenommene mono-exponentielle Verlauf wird durch ein multi-exponentielles Verhalten abgelöst, was vor allem in biologischem Gewebe eher der Wahrheit entspricht. Gewebe mit kurzen Relaxationskomponenten (T1* < 200 ms) sind klinisch relevant und mit T1* shuffling detektierbar. Vor allem Myelin innerhalb des Gehirns ist bei neurologischen Fragestellungen ein Indikator zur Diagnose im Frühstadium (z.B. für neurodegenerative Erkrankungen) und
deshalb von besonderem Interesse. Die Integration über verschiedene T1*-Zeitbereiche im
T1*-Spektrum ermöglicht dazu die Erstellung von Gewebekomponenten-Karten, mithilfe
derer klinische Auswertungen sinnvoll wären. Die Erstellung dieser Karten ist prinzipiell
möglich und funktioniert für mittlere und lange Gewebekomponenten recht gut. Die
klinisch relevanten kurzen Gewebekomponenten sind dagegen bei der radialen Aufnahme
mit nur einem Schuss noch nicht befriedigend. Deshalb wurde die Aufnahmetechnik in
eine quasi-zufällige kartesische Akquisition mit mehreren Schüssen weiterentwickelt. Die Ergebnisse wurden in Kapitel 7 vorgestellt und sind vielversprechend. Einzig die Messzeit sollte mit zusätzlichen Beschleunigungen noch weiter verkürzt und auf eine kartesische 3D-Akquisition erweitert werden.
Die Beschränkung auf T1*-Spektren bei der Multikomponentenanalyse und die Tatsache, dass deren Amplitude von einer Kombination von S0 und Sstst abhängen, führen dazu, dass es nicht ohne Weiteres möglich ist für einen einzelnen Gewebetyp an die T1- und T2-Information zu gelangen. In Kapitel 8 wurde gezeigt, dass dies mit einer zusätzlichen
Messung gelingen kann. Das finale Ergebnis dieser Messungen ohne und mit Inversion sind zweidimensionale Spektren, bei der für jede Gewebekomponente innerhalb eines Voxels der T1- und T2-Wert abgelesen werden kann. Wichtig hierbei ist die Tatsache, dass der verwendete Ansatz kein Vorwissen über die Anzahl der zu erwartenden Gewebekomponenten (Peaks) im Voxel voraussetzt. Auch bei dieser Methodik ist die Kenntnis über den tatsächlichen Flipwinkel von Bedeutung, da dieser in den Formeln zur Berechnung von T1 und T2 verwendet wird. Die Stabilität des B0-Feldes ist hier ebenso von enormer Bedeutung, da Änderungen zwischen den beiden Messungen zu einem unterschiedlichen Steady-State und somit zu Abweichungen bei den nachfolgenden Berechnungen führen, die auf den selben Steady-State-Wert ausgelegt sind.
Zusammenfassend lässt sich sagen, dass mit dieser Arbeit die Grundlagen für genauere
und robustere quantitative Messungen mittels Steady-State-Sequenzen gelegt wurden. Es
wurde gezeigt, dass sich Relaxationszeitspektren für jedes einzelne Voxel generieren lassen.
Dadurch ist eine verbesserte Auswertung möglich, um genauere Aussagen über die Zusammensetzung einer Probe (vor allem beim menschlichen Gewebe) treffen zu können. Zudem wurde die Theorie für ultraschnelle 2D-Relaxographie-Messungen vorgestellt. Erste”Proof of Principle“-Experimente zeigen, dass es möglich ist, 2D-Relaxationszeitspektren in sehr kurzer Zeit zu messen und graphisch darzustellen. Diese Aufnahme- und Datenverarbeitungstechnik ist in dieser Form einmalig und in der Literatur kann bis dato keine schnellere Methode gefunden werden.
Cyclisches Adenosinmonophosphat ist ein ubiquitärer zweiter Botenstoff zahlreicher Signalwege im menschlichen Körper. Auf eine Vielzahl verschiedenster extrazellulärer Signale folgt jedoch eine Erhöhung desselben intrazellulären Botenstoffs - cAMP. Nichtsdestotrotz schafft es die Zelle, Signalspezifität aufrecht zu erhalten. Ein anerkanntes, wenn auch bisher unverstandenes Modell, um dieses zu ermöglichen, ist das Prinzip der Kompartimentierung. Die Zelle besitzt demnach Areale verschieden hoher cAMP-Konzentrationen, welche lokal begrenzt einzelne Signalkaskaden beeinflussen und somit eine differenzierte Signalübertragung ermöglichen. Eine mögliche Ursache für die Ausbildung solcher Bereiche geringerer cAMP- Konzentrationen (hier als Domänen bezeichnet), ist die hydrolytische Aktivität von Phosphodiesterasen (PDEs), welche als einzige Enzyme die Fähigkeiten besitzen, cAMP zu degradieren.
In dieser Arbeit wird der Einfluss der cAMP-Hydrolyse verschiedener PDEs auf die Größe dieser Domänen evaluiert und mit denen der PDE4A1 verglichen, welche bereits durch unsere Arbeitsgruppe aufgrund ihrer Größe als Nanodomänen definiert wurden. Der Fokus wird dabei auf den Einfluss von kinetischen Eigenschaften der Phosphodiesterasen gelegt. So werden eine PDE mit hoher Umsatzgeschwindigkeit (PDE2A3) und eine PDE mit hoher Substrataffinität (PDE8A1) verglichen. Mithilfe sogenannter Linker, Abstandshaltern definierter Länge, werden zusätzlich die Nanodomänen ausgemessen, um einen direkten Zusammenhang zwischen Größe und kinetischer Eigenschaft anzugeben. Die Zusammenschau der Ergebnisse zeigt, dass die maximale Umsatzgeschwindigkeit der Phosphodiesterasen direkt mit der Größe der Nanodomänen korreliert.
Durch den unmittelbaren Vergleich der gesamten PDE mit ihrer katalytischen Domäne wird zusätzlich der Einfluss von regulatorischen Domänen evaluiert. Es wird gezeigt, dass diese cAMP-Gradienten modulieren können. Bei der PDE2A3 geschieht die Modulation u.a. durch Stimulation mit cGMP, welche höchstwahrscheinlich dosisabhängig ist und somit graduell verläuft. Hiermit präsentieren sich die Domänen als dynamische Bereiche, d.h. sie können in ihrer Ausprägung reguliert werden. In dieser Arbeit wird die Hypothese bestätigt, dass Phosphodiesterasen eine wichtige Rolle in der Kompartimentierung von cAMP spielen, die Gruppe jedoch inhomogener ist, als bislang angenommen. Die Gradienten-Bildung lässt sich nicht bei jeder Phosphodiesterase darstellen (PDE8A1). Einige Phosphodiesterasen (PDE2A3) jedoch bilden Kompartimente, die durch externe Stimuli in ihrer Größe reguliert werden können.
Die Arbeit legt den Grundstein zur breiteren Charakterisierung des spezifischen Einflusses weiterer PDEs auf cAMP-Kompartimentierung, welches nicht nur das Verständnis der Kompartimentierungs-Strategien voranbringt, sondern auch essentiell für das Verständnis der Pathophysiologie zahlreicher Krankheitsbilder, aber auch für das Verständnis bereits angewandter aber auch potentiell neuer Medikamente ist.
Within this thesis, three main approaches for the assessment and investigation of altered hemodynamics like wall shear stress, oscillatory shear index and the arterial pulse wave velocity in atherosclerosis development and progression were conducted:
1. The establishment of a fast method for the simultaneous assessment of 3D WSS and PWV in the complete murine aortic arch via high-resolution 4D-flow MRI
2. The utilization of serial in vivo measurements in atherosclerotic mouse models using high-resolution 4D-flow MRI, which were divided into studies describing altered hemodynamics in late and early atherosclerosis
3. The development of tissue-engineered artery models for the controllable application and variation of hemodynamic and biologic parameters, divided in native artery models and biofabricated artery models, aiming for the investigation of the relationship between atherogenesis and hemodynamics
Chapter 2 describes the establishment of a method for the simultaneous measurement of 3D WSS and PWV in the murine aortic arch at, using ultra high-field MRI at 17.6T [16], based on the previously published method for fast, self-navigated wall shear stress measurements in the murine aortic arch using radial 4D-phase contrast MRI at 17.6 T [4]. This work is based on the collective work of Dr. Patrick Winter, who developed the method and the author of this thesis, Kristina Andelovic, who performed the experiments and statistical analyses. As the method described in this chapter is basis for the following in vivo studies and undividable into the sub-parts of the contributors without losing important information, this chapter was not split into the single parts to provide fundamental information about the measurement and analysis methods and therefore better understandability for the following studies. The main challenge in this chapter was to overcome the issue of the need for a high spatial resolution to determine the velocity gradients at the vascular wall for the WSS quantification and a high temporal resolution for the assessment of the PWV without prolonging the acquisition time due to the need for two separate measurements. Moreover, for a full coverage of the hemodynamics in the murine aortic arch, a 3D measurement is needed, which was achieved by utilization of retrospective navigation and radial trajectories, enabling a highly flexible reconstruction framework to either reconstruct images at lower spatial resolution and higher frame rates for the acquisition of the PWV or higher spatial resolution and lower frame rates for the acquisition of the 3D WSS in a reasonable measurement time of only 35 minutes. This enabled the in vivo assessment of all relevant hemodynamic parameters related to atherosclerosis development and progression in one experimental session. This method was validated in healthy wild type and atherosclerotic Apoe-/- mice, indicating no differences in robustness between pathological and healthy mice.
The heterogeneous distribution of plaque development and arterial stiffening in atherosclerosis [10, 12], however, points out the importance of local PWV measurements. Therefore, future studies should focus on the 3D acquisition of the local PWV in the murine aortic arch based on the presented method, in order to enable spatially resolved correlations of local arterial stiffness with other hemodynamic parameters and plaque composition.
In Chapter 3, the previously established methods were used for the investigation of changing aortic hemodynamics during ageing and atherosclerosis in healthy wild type and atherosclerotic Apoe-/- mice using the previously established methods [4, 16] based on high-resolution 4D-flow MRI. In this work, serial measurements of healthy and atherosclerotic mice were conducted to track all changes in hemodynamics in the complete aortic arch over time. Moreover, spatially resolved 2D projection maps of WSS and OSI of the complete aortic arch were generated. This important feature allowed for the pixel-wise statistical analysis of inter- and intragroup hemodynamic changes over time and most importantly – at a glance. The study revealed converse differences of local hemodynamic profiles in healthy WT and atherosclerotic Apoe−/− mice, with decreasing longWSS and increasing OSI, while showing constant PWV in healthy mice and increasing longWSS and decreasing OSI, while showing increased PWV in diseased mice. Moreover, spatially resolved correlations between WSS, PWV, plaque and vessel wall characteristics were enabled, giving detailed insights into coherences between hemodynamics and plaque composition. Here, the circWSS was identified as a potential marker of plaque size and composition in advanced atherosclerosis. Moreover, correlations with PWV values identified the maximum radStrain could serve as a potential marker for vascular elasticity. This study demonstrated the feasibility and utility of high-resolution 4D flow MRI to spatially resolve, visualize and analyze statistical differences in all relevant hemodynamic parameters over time and between healthy and diseased mice, which could significantly improve our understanding of plaque progression towards vulnerability. In future studies the relation of vascular elasticity and radial strain should be further investigated and validated with local PWV measurements and CFD.
Moreover, the 2D histological datasets were not reflecting the 3D properties and regional characteristics of the atherosclerotic plaques. Therefore, future studies will include 3D plaque volume and composition analysis like morphological measurements with MRI or light-sheet microscopy to further improve the analysis of the relationship between hemodynamics and atherosclerosis.
Chapter 4 aimed at the description and investigation of hemodynamics in early stages of atherosclerosis. Moreover, this study included measurements of hemodynamics at baseline levels in healthy WT and atherosclerotic mouse models. Due to the lack of hemodynamic-related studies in Ldlr-/- mice, which are the most used mouse models in atherosclerosis research together with the Apoe-/- mouse model, this model was included in this study to describe changing hemodynamics in the aortic arch at baseline levels and during early atherosclerosis development and progression for the first time. In this study, distinct differences in aortic geometries of these mouse models at baseline levels were described for the first time, which result in significantly different flow- and WSS profiles in the Ldlr-/- mouse model. Further basal characterization of different parameters revealed only characteristic differences in lipid profiles, proving that the geometry is highly influencing the local WSS in these models. Most interestingly, calculation of the atherogenic index of plasma revealed a significantly higher risk in Ldlr-/- mice with ongoing atherosclerosis development, but significantly greater plaque areas in the aortic arch of Apoe-/- mice. Due to the given basal WSS and OSI profile in these two mouse models – two parameters highly influencing plaque development and progression – there is evidence that the regional plaque development differs between these mouse models during very early atherogenesis.
Therefore, future studies should focus on the spatiotemporal evaluation of plaque development and composition in the three defined aortic regions using morphological measurements with MRI or 3D histological analyses like LSFM. Moreover, this study offers an excellent basis for future studies incorporating CFD simulations, analyzing the different measured parameter combinations (e.g., aortic geometry of the Ldlr-/- mouse with the lipid profile of the Apoe-/- mouse), simulating the resulting plaque development and composition. This could help to understand the complex interplay between altered hemodynamics, serum lipids and atherosclerosis and significantly improve our basic understanding of key factors initiating atherosclerosis development.
Chapter 5 describes the establishment of a tissue-engineered artery model, which is based on native, decellularized porcine carotid artery scaffolds, cultured in a MRI-suitable bioreactor-system [23] for the investigation of hemodynamic-related atherosclerosis development in a controllable manner, using the previously established methods for WSS and PWV assessment [4, 16]. This in vitro artery model aimed for the reduction of animal experiments, while simultaneously offering a simplified, but completely controllable physical and biological environment. For this, a very fast and gentle decellularization protocol was established in a first step, which resulted in porcine carotid artery scaffolds showing complete acellularity while maintaining the extracellular matrix composition, overall ultrastructure and mechanical strength of native arteries. Moreover, a good cellular adhesion and proliferation was achieved, which was evaluated with isolated human blood outgrowth endothelial cells. Most importantly, an MRI-suitable artery chamber was designed for the simultaneous cultivation and assessment of high-resolution 4D hemodynamics in the described artery models. Using high-resolution 4D-flow MRI, the bioreactor system was proven to be suitable to quantify the volume flow, the two components of the WSS and the radStrain as well as the PWV in artery models, with obtained values being comparable to values found in literature for in vivo measurements. Moreover, the identification of first atherosclerotic processes like intimal thickening is achievable by three-dimensional assessment of the vessel wall morphology in the in vitro models. However, one limitation is the lack of a medial smooth muscle cell layer due to the dense ECM. Here, the utilization of the laser-cutting technology for the generation of holes and / or pits on a microscale, eventually enabling seeding of the media with SMCs showed promising results in a first try and should be further investigated in future studies. Therefore, the proposed artery model possesses all relevant components for the extension to an atherosclerosis model which may pave the way towards a significant improvement of our understanding of the key mechanisms in atherogenesis.
Chapter 6 describes the development of an easy-to-prepare, low cost and fully customizable artery model based on biomaterials. Here, thermoresponsive sacrificial scaffolds, processed with the technique of MEW were used for the creation of variable, biomimetic shapes to mimic the geometric properties of the aortic arch, consisting of both, bifurcations and curvatures. After embedding the sacrificial scaffold into a gelatin-hydrogel containing SMCs, it was crosslinked with bacterial transglutaminase before dissolution and flushing of the sacrificial scaffold. The hereby generated channel was subsequently seeded with ECs, resulting in an easy-to-prepare, fast and low-cost artery model. In contrast to the native artery model, this model is therefore more variable in size and shape and offers the possibility to include smooth muscle cells from the beginning. Moreover, a custom-built and highly adaptable perfusion chamber was designed specifically for the scaffold structure, which enabled a one-step creation and simultaneously offering the possibility for dynamic cultivation of the artery models, making it an excellent basis for the development of in vitro disease test systems for e.g., flow-related atherosclerosis research. Due to time constraints, the extension to an atherosclerosis model could not be achieved within the scope of this thesis. Therefore, future studies will focus on the development and validation of an in vitro atherosclerosis model based on the proposed bi- and three-layered artery models.
In conclusion, this thesis paved the way for a fast acquisition and detailed analyses of changing hemodynamics during atherosclerosis development and progression, including spatially resolved analyses of all relevant hemodynamic parameters over time and in between different groups. Moreover, to reduce animal experiments, while gaining control over various parameters influencing atherosclerosis development, promising artery models were established, which have the potential to serve as a new platform for basic atherosclerosis research.
Chronic Kidney Disease as an Important Co-morbid Condition in Coronary Heart Disease Patients
(2019)
In patients with coronary heart disease (CHD) the control of the modifiable “traditional” cardiovascular risk factors such as hypertension, dyslipidemia, diabetes, achieving/maintaining normal body weight and smoking cessation is of major importance to improve prognosis. Guideline recommendations for secondary CHD prevention include specific treatment targets for blood pressure, lipid levels, and markers of glucose metabolism for both younger and older patients. Chronic kidney disease (CKD) has been identified as a “non-traditional” risk factor for worse outcome in CHD patients, as it is associated with a markedly increased risk for subsequent CV events and mortality.
The specific objectives of the current thesis-project are to investigate (a) the quality of care in a recent sample of German CHD patients and to investigate variation of risk factor control between younger and elder patients (≤70 versus >70 years), (b) to analyze the prevalence of CKD across Europe in stable CHD patients in the outpatient setting and during a hospital stay for CHD, (c) to investigate the level of awareness of CKD in German CHD patients and their treating physicians.
Data from the European-wide EUROASPIRE IV study were used that include data on 7998 CHD patients in the ambulatory setting (study visit) and during a hospital stay for CHD (index). The German EUROASPIRE IV study center in Würzburg recruited 536 patients in 2012-2013. Risk factor control was compared against the current recommendations of the European Society of Cardiology. CKD was described by stages of glomerular filtration rate (eGFR) and albuminuria. German patients were asked in an additional kidney specific module whether they have ever been told by a physician about renal impairment. The fact that CKD or acute kidney injury (AKI) was mentioned in prominent parts of the hospital discharge letter as well as correct ICD-coding of CKD or AKI served as a proxy for physician’s awareness of CKD.
The majority of German CHD patients was treated with the recommended drug therapies including e.g. β-blockers, anti-platelets and statins. However, treatment targets for blood pressure and LDL-cholesterol levels were not achieved in many patients (45% and 53%, respectively) and glycemic control in diabetic CHD patients with HbA1-levels <7% was insufficient (61%). A minority of patients reported on current smoking (10%), but unhealthy life-styles e.g. overweight/obesity (85%/37%) were frequent. Patterns of care differed between younger and older CHD patients while older patients were less likely to receive the recommended medical CHD-therapy, were more likely to have uncontrolled blood pressure and also to be diabetic. However, a greater proportion of diabetic patients >70 years was achieving the HbA1c target, and less elder patients were current smokers or were obese. About 17% of patients on average had CKD (eGFR< 60 ml/min/1.73m²) in the entire European sample at the study visit, and an additional 10% had albuminuria despite preserved eGFR, with considerable variation among countries. Impaired kidney function was observed in every fifth patient admitted for CHD in the entire European dataset of the EUROASPIRE IV study. Of the German CHD patients with CKD at the study visit, only a third were aware of their renal impairment. A minority of these patients was being seen by nephrologists, however, with a higher likelihood of CKD awareness and specialist care in more advanced stages of CKD. About a third of patients admitted for CHD showed either CKD or AKI during the hospital stay, but the discharge letter mentioned chronic or acute kidney disease only in every fifth of these patients. In contrast, correct ICD coding of CKD or AKI was more complete, but still suboptimal.
In summary, quality of secondary prevention in German CHD patients indicates considerably room for improvement, with life-style modifications may become an even greater factor in prevention campaigns than medical treatment into certain target ranges. Preventive therapies should also consider different needs in older individuals acknowledging physical and mental potential, other comorbidities and drug-interactions with co-medication. CKD is common in CHD patients, not only in the elderly. Since CHD and CKD affect each other and impact on worse prognosis of each other, raising the awareness of CKD among patients and physicians and considering CKD in medical therapy may improve prognosis and slow disease progression of CHD as well as CKD.
Der implantierbare Kardioverter/Defibrillator wird zum Schutz vor einem plötzlichen Herztod aufgrund maligner Herzrhythmusstörungen eingesetzt. Detektionsalgorithmen sollen dabei den Herzrhythmus korrekt klassifizieren und bei ventrikulären Tachykardien eine Therapie mittels Überstimulation oder Schockabgabe auslösen, nicht jedoch bei tachykardem Vorhofflimmern. Die Vermeidung solcher inadäquater Therapieabgaben stellt eine Herausforderung an die Detektionsalgorithmen der Implantate da.
Bei steigender Prävalenz des Vorhofflimmerns auch bei ICD-Trägern stellt sich daher die Frage nach dem Einfluss dieser Rhythmusstörung auf die Versorgung dieser Patientengruppe.
In der vorliegenden Arbeit sind retrospektiv die Daten von ICD-Trägern mit Vorhofflimmern und ICD-Trägern ohne Vorhofflimmern bezüglich der gewählten Implantate, Häufigkeit adäquater und inadäquater Therapieabgaben und der daraus resultierenden Maßnahmen untersucht worden.
In der Auswertung zeigt sich, dass Patienten mit Vorhofflimmern tendenziell mehr inadäquate Therapien erlitten und signifikant häufiger hospitalisiert werden mussten. Anhand der Daten zeigt sich, dass Vorhofflimmern maßgeblich die Versorgung dieser Patientengruppen beeinflusst.
Die Na+ /K+ -ATPase (NKA) ist maßgeblich an der Regulation der kardialen Na+ -Homöostase beteilligt. Im Myokard werden hauptsächlich zwei Isoformen exprimiert: die α1 (NKA-α1) und die α2-Isoform (NKA-α2). Diese beiden Isoformen unterscheiden sich sowohl in ihrer Lokalisation als auch in ihrer zellulären Funktion. So ist die NKA-α1 recht homogen entlang des Sarkolemms zu finden und ist verantwortlich für die Regulation der globalen intrazellulären Na+ -Konzentration ([Na+ ]i). Die NKA-α2 hingegen konzentriert sich hauptsächlich in den T-Tubuli und beeinflusst über Veränderung der lokalen [Na+ ]i die Ca2+ -Transienten und die Kontraktilität. Im Rahmen einer Herzinsuffizienz wurde eine verminderte Expression und Aktivität der NKA beobachtet. Gleichzeitig werden Inhibitoren der NKA, sogenannte Digitalisglykoside, in fortgeschrittenen Herzinsuffizienz-Stadien eingesetzt. Die Studienlage über den Einsatz dieser Therapeutika ist recht uneinheitlich und reicht von einer verringerten Hospitalisierung bis hin zu einer erhöhten Mortalität. Ziel dieser Arbeit war es die Folgen einer NKA-α2 Aktivierung während einer Herzinsuffizienz mit Hilfe eines murinen Überexpressionsmodells zu analysieren. 11-Wochen alte Mäuse mit einer kardialen NKA-α2 Überexpression (NKA-α2) und Wildtyp (WT) Versuchstiere wurden einem 8-wöchigen Myokardinfarkt (MI) unterzogen. NKA-α2 Versuchstiere waren vor einem pathologischem Remodeling und einer kardialen Dysfunktion geschützt. NKA-α2 Kardiomyozyten zeigten eine erhöhte Na+ /Ca2+ -Austauscher (NCX) Aktivität, die zu niedrigeren diastolischen und systolischen Ca2+ -Spiegeln führte und einer Ca2+ -Desensitisierung der Myofibrillen entgegenwirkte. WT Versuchstiere zeigten nach chronischem MI eine sarkoplasmatische Ca2+ -Akkumulation, die in NKA-α2 Kardiomyozyten ausblieb. Gleichzeitig konnte in der NKA-α2 MI Kohorte im Vergleich zu den WT MI Versuchstieren eine erhöhte Expression von β1-adrenergen Rezeptoren (β1AR) beobachtet werden, die eine verbesserte Ansprechbarkeit gegenüber β-adrenergen Stimuli bewirkte. Zudem konnte in unbehandelten Versuchstieren eine Interaktion zwischen NKA-α2 und dem β1AR nachgewiesen werden, welche in der WT Kohorte größer ausfiel als in der NKA-α2 Versuchsgruppe. Gleichzeitig zeigten unbehandelte NKA-α2 Kardiomyozyten eine erhöhte Sensitivität gegenüber β-adrenerger Stimulation auf, welche nicht mit einer erhöhten Arrhythmie-Neigung oder vermehrten Bildung reaktiver Sauerstoffspezies einherging. Diese Untersuchungen zeigen, dass eine NKA-α2 Überexpression vor pathologischem Remodeling und einer kardialen Funktionbeeinträchtigung schützt, indem eine systolische, diastolische und sarkoplasmatische Ca2+ -Akkumulation verhindert wird. Gleichzeitig wird die β1AR Expression stabilisert, wodurch es zu einer verminderten neurohumoralen Aktivierung und einer Durchbrechung des Circulus vitiosus kommen könnte. Insgesamt scheint eine Aktivierung der NKA-α2 durchaus ein vielversprechendes Target in der Herzinsuffizienz Therapie darzustellen.
Therapie darzustellen.
Die Identifikation der Bindungsspezifitäten von Proteininteraktionsdomänen und damit letztlich auch die Fähigkeit potentielle Bindungspartner dieser in vivo vorherzusagen bildet ein grundlegendes Element für das Verständnis der biologischen Funktionen dieser Domänen. In dieser Arbeit wurde untersucht, inwieweit solche Vorhersagen bezüglich der SH3-Domäne – als Beispiel für eine Proteininteraktionsdomäne – mithilfe von Support-Vector-Machines (SVMs) möglich sind, wenn diesen als Informationsquelle ausschließlich die innerhalb der Aminosäuresequenz der Domäne konservierten Informationen zur Verfügung stehen. Um den SVM-basierten Klassifikator zu trainieren und zu validieren, wurde ein Satz aus 51 SH3-Domänen verwendet, die zuvor entsprechend ihrer Ligandenpräferenz in ein System aus acht verschiedenen Klassen eingeteilt worden waren. Da die innerhalb der Aminosäuresequenzen konservierten Informationen in abstrakte Zahlenwerte konvertiert werden mussten (Voraussetzung für mathematisch basierte Klassifikatoren wie SVMs), wurde jede Aminosäuresequenz durch ihren jeweiligen Fisher-Score-Vektor ausgedrückt. Die Ergebnisse erbrachten einen Klassifikationserror, welcher weit unterhalb des Zufallsniveaus lag, was darauf hindeutet, dass sich die Bindungsspezifität (Klasse) einer SH3-Domäne in der Tat von seiner Aminosäuresequenz ableiten lassen dürfte. Mithilfe klassenspezifisch emittierter, artifizieller Sequenzen, implementiert in den Trainingsprozess des Klassifikators, um etwaigen nachteiligen Auswirkungen von Overfitting zu entgegenzuwirken, sowie durch Berücksichtigung taxonomischer Informationen des Klassensystems während Training und Validierung, ließ sich der Klassifikationserror sogar noch weiter senken und lag schließlich bei lediglich 35,29% (vergleiche Zufall: 7/8 = 87.50%). Auch die Nutzung von Feature Selections zur Abmilderung Overfitting-bedingter, negativer Effekte lieferte recht vielversprechende Ergebnisse, wenngleich ihr volles Potential aufgrund von Software-Beschränkungen nicht ausgenutzt werden konnte.
Die Analyse der Positionen im Sequence-Alignment, welche für den SVM- basierten Klassifikator am relevantesten waren, zeigte, dass diese häufig mit Positionen korrelierten, von denen angenommen wird auch in vivo eine Schlüsselrolle bei der Determination der Bindungsspezifität (Klasse) zu spielen. Dies unterstreicht nicht nur die Reliabilität des präsentierten Klassifikators, es gibt auch Grund zur Annahme, dass das Verfahren möglicherweise auch als Supplement anderer Ansätze genutzt werden könnte, welche zum Ziel haben die Positionen zu identifizieren, die die Ligandenpräferenz in vivo determinieren. Informationen, die nicht nur für ein besseres Verständnis der SH3-Domäne (und möglicherweise auch anderer Proteininteraktionsdomänen) von grundlegender Bedeutung sind, sondern auch aus pharmakologischer Sicht von großem Interesse sein dürften.
Clinical practice in CMR with respect to cardiovascular disease is currently focused on tissue characterization, and cardiac function, in particular. In recent years MRI based diffusion tensor imaging (DTI) has been shown to enable the assessment of microstructure based on the analysis of Brownian motion of water molecules in anisotropic tissue, such as the myocardium. With respect to both functional and structural imaging, 7T MRI may increase SNR, providing access to information beyond the reach of clinically applied field strengths. To date, cardiac 7T MRI is still a research modality that is only starting to develop towards clinical application.
In this thesis we primarily aimed to advance methods of ultrahigh field CMR using the latest 7T technology and its application towards the functional and structural characterization of the myocardium.
Regarding the assessment of myocardial microstructure at 7T, feasibility of ex vivo DTI of large animal hearts was demonstrated. In such hearts a custom sequence implemented for in vivo DTI was evaluated and fixation induced alterations of derived diffusion metrics and tissue properties were assessed. Results enable comparison of prior and future ex vivo DTI studies and provide information on measurement parameters at 7T.
Translating developed methodology to preclinical studies of mouse hearts, ex vivo DTI provided highly sensitive surrogates for microstructural remodeling in response to subendocardial damage. In such cases echocardiography measurements revealed mild diastolic dysfunction and impaired longitudinal deformation, linking disease induced structural and functional alterations. Complementary DTI and echocardiography data also improved our understanding of structure-function interactions in cases of loss of contractile myofiber tracts, replacement fibrosis, and LV systolic failure.
Regarding the functional characterization of the myocardium at 7T, sequence protocols were expanded towards a dedicated 7T routine protocol, encompassing accurate cardiac planning and the assessment of cardiac function via cine imaging in humans.
This assessment requires segmentation of myocardial contours. For that, artificial intelligence (AI) was developed and trained, enabling rapid automatic generation of cardiac segmentation in clinical data. Using transfer learning, AI models were adapted to cine data acquired using the latest generation 7T system. Methodology for AI based segmentation was translated to cardiac pathology, where automatic segmentation of scar tissue, edema and healthy myocardium was achieved.
Developed radiofrequency hardware facilitates translational studies at 7T, providing controlled conditions for future method development towards cardiac 7T MRI in humans.
In this thesis the latest 7T technology, cardiac DTI, and AI were used to advance methods of ultrahigh field CMR. In the long run, obtained results contribute to diagnostic methods that may facilitate early detection and risk stratification in cardiovascular disease.
Die Magnetresonanztomographie stellt den Goldstandard zur kardialen Funktionsdiagnostik dar und ermöglicht die nicht-invasive Analyse der Herzfunktion mit valider Bestimmung von Volumina, Flüssen sowie der Ejektionsfraktion in vivo. In unserer Arbeitsgruppe erfolgt eine stetige Weiterentwicklung der Methode am Rattenmodell, wobei regelhaft eine Narkose des Versuchtstiers notwendig ist. Im Rahmen meiner Arbeit wurde der Effekt verschiedener Narkoseformen auf die Herzfunktion untersucht. Dabei wurde eine Isoflurannarkose einer Narkose mittels Propofol sowie Propofol in Kombination mit Pancuronium gegenübergestellt. Hierbei zeigen sich teilweise deutliche Unterschiede in den kardialen Funktionsparametern während der Untersuchung. Hieraus ist zu folgern, dass ein sinnvoller Vergleich der Herzfunktion von Versuchsreihen mit unterschiedlicher Narkosetechnik problematisch ist. Dies unterstreicht die Wichtigkeit einer Festlegung der Narkosetechnik vor Beginn einer Versuchsreihe in der kardiovaskulären Forschung und deren Konstanthaltung über die gesamte Versuchsdauer.
Atherosklerose ist ein wichtiger Faktor bezüglich der Pathogenese kardiovaskulärer Erkrankungen, indem sie Einfluss auf die strukturellen und funktionellen Eigenschaften der Gefäße nimmt. Wegen dieser Bedeutung ist es wichtig, diese Erkrankung und deren Zusammenhänge genau zu erforschen.
Einige Studien konnten zeigen, dass die Pulswellengeschwindigkeit mit Gefäßwand-eigenschaften, insbesondere deren Steifigkeit, zusammenhängt. So konnte in Untersuchungen von Gotschy et al.27 eine Zunahme der lokalen Pulswellen-geschwindigkeit, als Marker für Gefäßwandsteifigkeit, in Aortenanteilen von ApoE(-/-)-Mäusen im Zeitverlauf mittels MRT gezeigt werden, ohne dass makroskopische Veränderungen in frühen Stufen atherosklerotischer Entwicklung sichtbar waren. Dies wird nun als Ausgangspunkt herangezogen, um zu erforschen, durch welche histologischen Veränderungen des Gefäßes innerhalb der Atherogenese eine frühe Zunahme der lokalen PWV erklärt werden kann.
Hierzu wird zum einen die mit der Gefäßwandsteifigkeit in Zusammenhang gebrachte Elastinfragmentierung innerhalb der elastischen Laminae der Aorta ascendens und abdominalis mittels histologischer Untersuchung quantitativ bestimmt. Die elastischen Schichten werden durch modifizierte Elastika-van-Gieson-Färbung dargestellt. Zur vergleichenden Bestimmung wird ein Quotient aus der Anzahl bei mikroskopischer Betrachtung erkennbarer Brüche der elastischen Laminae und bestimmter Gefäßwandquerschnittsfläche erstellt. Die Ausprägung der Elastinfragmentierung unterscheidet sich signifikant in den zwei höchsten Altersklassen der Test- und Kontrollmäuse in beiden untersuchten Aortenabschnitten, wobei die ApoE(-/-)-Tiere stets den höheren Wert aufweisen. Anhand der Ähnlichkeit hinsichtlich der Entwicklung der Messwerte von beschriebener lokalen PWV und der hier gezeigten Elastinfragmentierung kann vermutet werden, dass diese zu einer Erhöhung der Gefäßwandsteifigkeit beiträgt. Die gezeigten histologischen Parameter können so als Indikator für Veränderungen der Gefäßeigenschaften während der Atherogenese und als möglicher Grund einer Veränderung der Gefäßwandsteifigkeit mit konsekutiver Erhöhung der lokalen PWV angesehen werden.
Als weiterer Einflussfaktor auf die mechanischen Eigenschaften des Blutgefäßsystems wird die Entwicklung des Kollagengehaltes anteilig an der Aortenwand bestimmt. Es wurde in vielen Publikationen beschrieben, welchen großen Stellenwert Kollagenfasern für die Gefäßwandsteifigkeit haben. Auch wird das untersuchte Kollagen hinsichtlich seiner Faserdicken nochmals genauer untersucht. Die Kollagenfasern werden mittels Pikro-Sirius-Rot gefärbt und anschließend unter zirkulär polarisiertem Licht analysiert. Die erhaltenen Ergebnisse zeigen keinen eindeutigen Trend hinsichtlich ihrer Entwicklung. Sie lassen sich auch nicht mit der aufgestellten Hypothese in Übereinkunft bringen, da keine zeitliche Dynamik verglichen mit der Entwicklung der anderen Parameter nachgewiesen werden kann.
Um den beschriebenen entzündlichen Charakter der Atherogenese ebenso zu berücksichtigen, wird das Einwanderungsverhalten von Makrophagen in die Gefäßwand betrachtet. Es wird die relative Fläche der durch Makrophagen besiedelten Gefäßwandanteile bestimmt und als Indikator einer Entzündungsreaktion angesehen, welche direkt oder indirekt Einfluss auf Gefäßwandeigenschaften haben könnte. Mittels eines Antikörpers gegen das makrophagenspezifische Protein CD68 und Kombination mit anti-antikörpervermittelt bindenden fluoreszierenden Substanzen, werden Makrophagen in einem Fluoreszenzmikroskop sichtbar gemacht und die besiedelte Fläche softwaregestützt bestimmt. Dabei kommt die vorliegende Untersuchung zu dem Ergebnis, dass sich die Makrophagenbesiedelung in beiden betrachteten Aortenabschnitten deutlich im Zeitverlauf bei den ApoE(-/-)-Tieren erhöht. Der relative Gefäßwandanteil der von Makrophagen besiedelten Flächen erreicht seinen höchsten Wert innerhalb der Aorta ascendens bei 18 Wochen alten ApoE(-/-)-Tieren; in der Aorta abdominalis bei 30 Wochen alten. Die absolute CD68-Fläche in beiden Aortenabschnitten steigt bis zum Versuchsende hin an, wobei der stärkste Anstieg in der Zeit von sechs zu 18 Wochen geschieht. Dagegen zeigt die Kontrollgruppe eine sehr geringe Zunahme dieser beiden Messgrößen, wobei diese stets auf einem sehr niedrigen Niveau bleiben und keineswegs mit der Entwicklung der Testtiere zu vergleichen sind. Besonders zu beachten ist, das bereits in der jüngsten Altersstufe von sechs Wochen ein höheres Maß an Makrophagenbesiedelung bei Aortenanteilen der ApoE(-/-)-Tiere zu verzeichnen ist, als bei den entsprechenden Kontrollen. Auf Grund dieser Beobachtung, lässt sich ein möglicher Zusammenhang mit der schon früh ansteigenden Gefäßsteifigkeit vor sichtbarer Plaqueentwicklung herstellen.
Bei der Klärung der zentralen Fragestellung dieser Arbeit nach einem histomorphologischen Korrelat für die frühzeitige Erhöhung der lokalen PWV zeigt sich folgendes Ergebnis: Insgesamt können die gemessenen histologischen Charakteristika, vor allem die Entwicklung der Elastinfragmentierung innerhalb der Gefäßwand und der Grad der Makrophagenbesiedelung, frühe Indikatoren für Veränderungen morphologischer und funktioneller Gefäßwandspezifikationen sein. Sie kommen daher als denkbare Ursache für den Anstieg der lokalen Pulswellengeschwindigkeit in Betracht, besonders da die zuvor erwähnten histologischen Parameter zeitlich wie diese einen ähnlichen Verlauf hinsichtlich ihrer Entwicklung zeigen.
Die Atherogenese und deren zahlreiche Einflussfaktoren bleiben weiterhin Forschungs-gegenstand und es gilt mehr denn je mögliche Mechanismen aufzudecken, um eine Gefäßwandschädigung frühzeitig und effektiv verhindern zu können. Hiervon würde ein Großteil der Bevölkerung profitieren, da die Atherosklerose durch ihre Folgeerkrankungen nach wie vor, nicht nur in Deutschland, die Todesursachenstatistik anführt.