Institut für Anatomie und Zellbiologie
Refine
Has Fulltext
- yes (285)
Year of publication
Document Type
- Journal article (171)
- Doctoral Thesis (100)
- Complete part of issue (10)
- Conference Proceeding (3)
- Preprint (1)
Language
- English (163)
- German (119)
- Multiple languages (3)
Keywords
- multiple sclerosis (11)
- Endothel (9)
- Multiple Sklerose (9)
- EAE (8)
- B cells (7)
- Habichtskraut (7)
- Geobotanik (6)
- MS (6)
- Pemphigus (6)
- Pflanzengeographie (6)
Institute
- Institut für Anatomie und Zellbiologie (285)
- Graduate School of Life Sciences (17)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (13)
- Neurologische Klinik und Poliklinik (9)
- Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I) (8)
- Klinik und Poliklinik für Anästhesiologie (ab 2004) (7)
- Theodor-Boveri-Institut für Biowissenschaften (7)
- Institut für Pharmakologie und Toxikologie (6)
- Klinik und Poliklinik für Nuklearmedizin (5)
- Klinik und Poliklinik für Unfall-, Hand-, Plastische und Wiederherstellungschirurgie (Chirurgische Klinik II) (5)
Sonstige beteiligte Institutionen
- Department of Biomedical Imaging, National Cerebral and Cardiovascular Research Center, Suita, Japan (2)
- Division of Medical Technology and Science, Department of Medical Physics and Engineering, Course of Health Science, Osaka University Graduate School of Medicine, Suita Japan (2)
- Institut for Molecular Biology and CMBI, Department of Genomics, Stem Cell Biology and Regenerative Medicine, Leopold-Franzens-University Innsbruck, Innsbruck, Austria (2)
- Johns Hopkins School of Medicine, The Russell H Morgan Department of Radiology and Radiological Science, Baltimore, MD, USA (2)
- Naturalis Biodiversity Centre (2)
- Johns Hopkins School of Medicine (1)
- Johns Hopkins School of Medicine, Baltimore, MD, U.S. (1)
Rationale and Objectives
Cone-beam CT (CBCT) applications possess potential for dose reduction in musculoskeletal imaging. This study evaluates the ultra-high-resolution CBCT prototype of a twin robotic X-ray system in wrist examinations compared to high-resolution multidetector CT (MDCT).
Materials and Methods
Sixteen wrists of body donors were examined with the CBCT scan mode and a 384 slice MDCT system. Radiation-equivalent low-dose (CTDIvol(16cm) = 3.3 mGy) and full-dose protocols (CTDIvol(16cm) = 13.8 mGy) were used for both systems. Two observers assessed image quality on a seven-point Likert scale. In addition, software-assisted quantification of signal intensity fractions in cancellous bone was performed. Fewer pixels with intermediate signal intensity were considered to indicate superior depiction of bone microarchitecture.
Results
Subjective image quality in CBCT was superior to dose equivalent MDCT with p ≤ 0.03 for full-dose and p < 0.001 for low-dose scans, respectively. Median Likert values were 7/7 (reader 1 / reader 2) in full-dose CBCT, 6/6 in full-dose MDCT, 5/6 in low-dose CBCT and 3/3 in low-dose MDCT. Intraclass correlation coefficient was 0.936 (95% confidence interval, 0.897-0.961; p < 0.001), indicating excellent reliability. Objective analysis displayed smaller fractions of “indecisive” pixels with intermediate signal intensity for full-dose CBCT (0.57 [interquartile range 0.13]) compared to full-dose MDCT (0.68 [0.21]), low-dose CBCT (0.72 [0.19]), and low-dose MDCT (0.80 [0.15]) studies. No significant difference was observed between low-dose CBCT and full-dose MDCT.
Conclusion
The new CBCT prototype provides superior image quality for trabecula and bone marrow in cadaveric wrist studies and enables dose reduction up to 75% compared to high-resolution MDCT.
Objectives
Detailed visualization of bone microarchitecture is essential for assessment of wrist fractures in computed tomography (CT). This study aims to evaluate the imaging performance of a CT system with clinical cadmium telluride-based photon-counting detector (PCD-CT) compared with a third-generation dual-source CT scanner with energy-integrating detector technology (EID-CT).
Materials and Methods
Both CT systems were used for the examination of 8 cadaveric wrists with radiation dose equivalent scan protocols (low-/standard-/full-dose imaging: CTDIvol = 1.50/5.80/8.67 mGy). All wrists were scanned with 2 different operating modes of the photon-counting CT (standard-resolution and ultra-high-resolution). After reformatting with comparable reconstruction parameters and convolution kernels, subjective evaluation of image quality was performed by 3 radiologists on a 7-point scale. For estimation of interrater reliability, we report the intraclass correlation coefficient (absolute agreement, 2-way random-effects model). Signal-to-noise and contrast-to-noise ratios were calculated to provide semiquantitative assessment of image quality.
Results
Subjective image quality of standard-dose PCD-CT examinations in ultra-high-resolution mode was superior compared with full-dose PCD-CT in standard-resolution mode (P = 0.016) and full-dose EID-CT (P = 0.040). No difference was ascertained between low-dose PCD-CT in ultra-high-resolution mode and standard-dose scans with either PCD-CT in standard-resolution mode (P = 0.108) or EID-CT (P = 0.470). Observer evaluation of standard-resolution PCD-CT and EID-CT delivered similar results in full- and standard-dose scans (P = 0.248/0.509). Intraclass correlation coefficient was 0.876 (95% confidence interval, 0.744–0.925; P < 0.001), indicating good reliability. Between dose equivalent studies, signal-to-noise and contrast-to-noise ratios were substantially higher in photon-counting CT examinations (all P's < 0.001).
Conclusions
Superior visualization of fine anatomy is feasible with the clinical photon-counting CT system in cadaveric wrist scans. The ultra-high-resolution scan mode suggests potential for considerable dose reduction over energy-integrating dual-source CT.
Isolation und Identifizierung von Photorezeptoren, Mikroglia und Müller Zellen der murinen Retina
(2024)
Ziel dieser Arbeit war die Etablierung zweier Methoden zur Analyse und Isolation retinaler Zellen. Das Augenmerk wurde dabei auf Photorezeptoren, Mikroglia und Müller Zellen gelegt.
Zur Darstellung der Spezifität der verwendeten Oberflächenmarker wurden diese auf retinalen Kryoschnitten eingesetzt und mittels Fluoreszenzmikroskop analysiert. Zur Analyse und Isolation von Zellen wurde zunächst ein Protokoll zur Herstellung einer Einzelzellsuspension etabliert, um im Anschluss mittels Durchflusszytometrie Photorezeptoren und Mikroglia Zellen als Zellpopulationen darzustellen und isolieren zu können. Weiterführend wurden Photorezeptoren und Mikroglia Zellen einer Mauslinie mit einer Deletion von Smad7 in retinalen Neuronen, Müller Zellen (Smad7∆oc Mäusen) sowie Photorezeptoren und Mikroglia Zellen der Kontrollgeschwistertiere isoliert und mittels qPCR ein signifikant geringeres Smad7 mRNA Expressionsniveau in den Smad7∆oc Photorezeptoren gezeigt.
Problematisch gestaltete sich die Isolation von Müller Zellen sowohl mittels Durchflusszytometrie aber auch mittels magnetisch aktivierter Zellseparation.
Diese Zellpopulation konnte in der vorliegenden Arbeit nicht erfolgreich isoliert werden. Weiterführende immunhistochemische Studien zeigten, dass der verwendete CD29 Antikörper, obwohl in der Literatur als zuverlässiger Müller-Zell-Marker beschrieben, eine starke Reaktivität mit Endothelzellen zeigt.
Zusammenfassend konnte durch die Daten dieser Promotion ein Protokoll etabliert werden, um mittels Durchflusszytometrie sowohl die Analyse als auch die Isolation von Photorezeptoren und Mikroglia aus murinen Retinae zu ermöglichen und diese in weiterführenden Studien zu verwenden.
Die vorliegende Nichtunterlegenheitsstudie zur Versorgung von Symphysensprengungen vergleicht die biomechanische Stabilität zweier neuartiger, additiv hergestellter Kabel- Implantat-Systeme zur Symphysenfixierung (KISS-Fixation) mit der der Symphysenplatte. Letztere weist als aktueller Standard eine erhebliche Komplikationsrate auf. Die Nullhypothese lautet: Die KISS-Fixation mit anteriorer oder transobturatorialer Kabelcerclage ist der Symphysenplatte bei der Versorgung einer Symphysensprengung in Bezug auf biomechanische Stabilität unterlegen.
Hierfür erfolgte eine Testung von insgesamt 30 synthetischen Beckenmodellen in einer Materialprüfmaschine unter Nachahmung eines Einbeinstandes. Zeitgleich wurden durch ein Optisches Messsystem Verschiebungen an der Symphyse gemessen. Getestet wurden drei Gruppen à zehn Becken: A) 3,5 mm 4-Loch-Symphysenplatte aus Stahl, B) KISS mit anteriorer Kabelcerclage und C) KISS mit transobturatorialer Kabelcerclage. Nach einer zyklischen Belastung unter dem Kraftniveau von 300 N über 5000 Zyklen erfuhr dasselbe Becken anschließend weitere 5000 Zyklen unter 400 N.
In einem zweiten Teil der Studie wurde die KISS-Fixation an insgesamt sechs Körperspendern angebracht. Dies diente der Etablierung des operativen Zugangswegs, Analyse umliegender Strukturen und Prüfung der Passgenauigkeit.
Aufgezeichnete Parameter der Materialprüfmaschine waren: Steifigkeit, Peak-to-Peak-Displacement, Total Displacement, Plastische Deformation sowie Dmin5000 – DmaxSZ10. Beim Optischen Messsystem erfolgte eine Auswertung der vertikalen Verschiebung von zwei an der Symphyse befindlichen Messpunkten zum Zeitpunkt des Belastungsmaximums (Symphyseal Displacement).
Für die Messwerte der Materialprüfmaschine konnte in 13 von 20 Parametern Nichtunterlegenheit der KISS-Fixation gegenüber der Symphysenplatte nachgewiesen werden. Beim Optischen Messsystem war das KISS in drei der insgesamt vier als relevant betrachteten Werte nichtunterlegen. Im Rahmen der Kadaverstudie bestätigte sich eine Praktizierbarkeit der Implantatanbringung am humanen Präparat.
Diese Studie zeigt, dass zur Stabilisierung einer Symphysensprengung die neuartige KISS-Fixation eine biomechanisch und anatomisch mögliche Alternative zur Symphysenplatte darstellt.
Background: Cellular glucose uptake may involve either non-concentrative glucose carriers of the GLUT family or Na\(^+\)-coupled glucose-carrier SGLT1, which accumulates glucose against glucose gradients and may thus accomplish cellular glucose uptake even at dramatically decreased extracellular glucose oncentrations. SGLT1 is not only expressed in epithelia but as well in tumour cells and immune cells. Immune cell functions strongly depend on their metabolism, therefore we hypothesized that deficiency of SGLT1 modulates the defence against bacterial infection. To test this hypothesis, we infected wild type mice and gene targeted mice lacking functional SGLT1 with Listeria monocytogenes.
Methods: SGLT1 deficient mice and wild type littermates were infected with 1x10\(^4\) CFU Listeria monocytogenes intravenously. Bacterial titers were determined by colony forming assay, SGLT1, TNF-α, IL-6 and IL-12a transcript levels were determined by qRT-PCR, as well as SGLT1 protein abundance and localization by immunohistochemistry.
Results: Genetic knockout of SGLT1 (Slc5a1\(^{–/–}\) mice) significantly compromised bacterial clearance following Listeria monocytogenes infection with significantly enhanced bacterial load in liver, spleen, kidney and lung, and significantly augmented hepatic expression of TNF-α and IL-12a. While all wild type mice survived, all SGLT1 deficient mice died from the infection.
Conclusions: SGLT1 is required for bacterial clearance and host survival following murine Listeria infection.
The production of human induced pluripotent stem cells (hiPSCs) in quantities that are relevant for cell-based therapies and cell-loaded implants through standard adherent culture is hardly achievable and lacks process scalability. A promising approach to overcoming these hurdles is the culture of hiPSCs in suspension. In this study, stirred suspension culture vessels were investigated for their suitability in the expansion of two hiPSC lines inoculated as a single cell suspension, with a free scalability between volumes of 50 and 2400 ml. The simple and robust two-step process reported here first generates hiPSC aggregates of 324 ± 71 μm diameter in 7 days in 125 ml spinner flasks (100 ml volume). These are subsequently dissociated into a single cell suspension for inoculation in 3000 ml bioreactors (1000 ml volume), finally yielding hiPSC aggregates of 198 ± 58 μm after 7 additional days. In both spinner flasks and bioreactors, hiPSCs can be cultured as aggregates for more than 40 days in suspension, maintain an undifferentiated state as confirmed by the expression of pluripotency markers TRA-1-60, TRA-1-81, SSEA-4, OCT4, and SOX2, can differentiate into cells of all three germ layers, and can be directed to differentiate into specific lineages such as cardiomyocytes. Up to a 16-fold increase in hiPSC quantity at the 100 ml volume was achieved, corresponding to a fold increase per day of 2.28; at the 1000 ml scale, an additional 10-fold increase was achieved. Taken together, 16 × 106 hiPSCs were expanded into 2 × 109 hiPSCs in 14 days for a fold increase per day of 8.93. This quantity of hiPSCs readily meets the requirements of cell-based therapies and brings their clinical potential closer to fruition.
Brustkrebs ist die häufigste diagnostizierte Krebserkrankung weltweit. Trotz der vielfältigen Behandlungsmöglichkeiten endet die Diagnose Brustkrebs in vielen Fällen noch immer tödlich. Aus diesem Grund ist die Entwicklung neuer Therapieansätze wichtig. Ein Therapieansatz, der in den letzten zehn Jahren immer mehr an Bedeutung gewonnen hat, ist die Immuntherapie. Allerdings konnte sie bei Brustkrebs noch keine großen Erfolge erzielen. Ursache hierfür ist die geringe Immunzellinfiltration in Brusttumoren. Um Brustkrebs für Immuntherapie empfänglicher zu machen, müssten Immuntherapeutika in Kombination mit Medikamenten angewendet werden, die die Immunzellinfiltration steigern. Um die Wirksamkeit solcher Medikamente in präklinischen Studien zu testen, braucht es eine Methode, mit der man die T-Zellverteilung innerhalb des Tumors darstellen kann. Für umfassendes Verständnis ist dreidimensionale Darstellung der Zellen im Tumor notwendig, da es einen großen Unterschied macht, ob sich die T-Zellen im Tumorstroma oder in unmittelbarer Nähe zu den Tumorzellen befinden. Die starke Fibrotisierung der Extrazellulären Matrix, die typisch für Brusttumoren ist, erschwert nicht nur die Immunzellinfiltration, sondern auch die Diffusion der fluoreszierenden Antikörper ins Gewebe. Im Zuge dieser Arbeit wurde eine Methode entwickelt, um im dreidimensionalen CD4 und CD8-positive T-Zellen in Brusttumoren darzustellen. Dies gelang mittels Immunfluoreszenzfärbung und anschließender dreidimensionaler Aufnahme mithilfe optischer Sektionierung am Lichtblattmikroskop. Erreicht wurde dies durch deutliche Erhöhung der Inkubationszeiten, aggressive Permeabilisierung des Gewebes, Testen unterschiedlicher Antikörper bzw. Antikörperkombinationen und Entfärbung sowie Klärung des Tumorgewebes. Darüber hinaus konnten erste Schritte in der nachträglichen Bearbeitung der Aufnahmen inklusive Rekonstruktion der Zellen gemacht werden. Für die Anwendung des Verfahrens in Studien zur Medikamentenwirksamkeit ist noch weitere Optimierung notwendig.
Die Tumorangiogenese ist ein Prozess, der zur Ausbildung eines tumoreigenen Gefäßnetzwerks führt und kritisch ist für die Progression des Tumorwachstums, sowie für dessen Malignisierung und Metastasierung. Zytokine wie VEGF und PDGF steuern angiogene Prozesse. Die resultierende Tumorvaskulatur ist jedoch dysfunktional und unterscheidet sich in Struktur und Funktion stark von normalen Gefäßen. Die antiangiogene Therapie richtet sich gegen die Tumorvaskulatur indem Angiogenese-induzierende Signalwege inhibiert werden. Es existieren zahlreiche therapeutische Ansätze, zu denen u.a. Anti-VEGF- Antikörper und Rezeptortyrosinkinaseinhibitoren zählen. Ziel der antiangiogenen Therapie ist es, die Ausbildung neuer Blutgefäße im Tumor zu stoppen sowie existierende unreife Blutgefäße zu zerstören. Das Konzept der Gefäßnormalisierung beschreibt im Rahmen der antiangiogenen Therapie Prozesse, die zu einer transienten Verbesserung dieser defekten Tumorvaskulatur und zu ihrer tendenziellen Angleichung an Struktur und Funktion von normalen Gefäßen führen sollen.
In dieser Studie wurden Veränderungen von Gefäßparametern in murinen AT3- Mammakarzinomen und murinen Lewis-lung-Karzinomen miteinander verglichen, die entweder (a) mit mG6-31, einem monoklonalen Anti-VEGF- Antikörper, (b) mit Axitinib, einem niedermolekularen VEGF-R-/PDGF-R- Tyrosinkinaseinhibitor antiangiogen behandelt oder (c) nicht behandelt wurden. Ziel war es dabei, Aussagen über die antiangiogene Wirksamkeit sowie die Gefäß- normalisierende Effektivität der o.g. Antiangiogenetika zu treffen. In einer bereits abgeschlossenen Forschungsarbeit von Ascheid (vgl. Absatz 7.2) wurden mit dem gleichen Experimentalaufbau wie zuvor beschrieben ebenfalls murine Tumoren hinsichtlich makroskopischer Gefäßstruktur und -organisation untersucht. Dabei wurde aufgezeigt, dass Gefäß-normalisierende Prozesse durch o.g. Angiogenetika in geringem Umfang stattfanden. Die durchgeführte Studie zielte darauf ab, die bereits erfassten Resultate zu komplettieren und somit eine abschließende Aussage über das Auftreten von Gefäßnormalisierung zu ermöglichen.
88
In den mG6-31-/Axitinib-/unbehandelten AT3-/LLC-Tumorschnitten wurden die Parameter Gefäßdichte, Apoptoserate, Proliferationsrate, Perizytenbesatz, Intaktheit der vaskulären Basalmembran und endotheliale Expression von TRPC6-Kanälen immunhistochemisch bzw. mittels Immunfluoreszenz detektiert, mikroskopisch aufgenommen und quantifiziert.
Diese Arbeit zeigt, dass Axitinib deutliche antiangiogene Effekte in der Tumorvaskulatur hervorruft, mG6-31 hingegen wirkt schwächer antiangiogen. Im Unterschied zu den Ergebnissen aus Ascheids Arbeit (Ascheid, 2018) konnten- Effekte auf der Ebene der individuellen Blutgefäße nachgewiesen werden, die in der Literatur als Anzeichen für eine Gefäßnormalisierung beschrieben werden. Wiederum waren diese Effekte unter Axitinib stärker ausgeprägt als unter mG6- 31-Behandlung. Die Resultate beider Forschungsarbeiten zusammengefasst betrachtet, kann man feststellen, dass die Zusammenfassung der gefäßverändernden Effekte, die antiangiogene Wirkstoffe hervorrufen, unter dem Begriff „Normalisierung“ in Frage gestellt werden sollte.
Recent dissection studies resulted in the introduction of the term “chiasma antebrachii”, which represents an intersection of the flexor digitorum superficialis (FDS) tendons for digits 2 and 3 in the distal third of the forearm. This retrospective investigation aimed to provide an MRI-based morphologic analysis of the chiasma antebrachii. In 89 patients (41 women, 39.3 ± 21.3 years), MRI examinations of the forearm (2010–2021) were reviewed by two radiologists, who evaluated all studies for the presence and length of the chiasma as well as its distance from the distal radioulnar and elbow joint. The chiasma antebrachii was identified in the distal third of the forearm in 88 patients (98.9%), while one intersection was located more proximally in the middle part. The chiasma had a median length of 28 mm (interquartile range: 24–35 mm). Its distances to the distal radioulnar and elbow joint were 16 mm (8–25 mm) and 215 mm (187–227 mm), respectively. T1-weighted post-contrast sequences were found to be superior to T2- or proton-density-weighted sequences in 71 cases (79.8%). To conclude, the chiasma antebrachii is part of the standard FDS anatomy. Knowledge of its morphology is important, e.g., in targeted injections of therapeutics or reconstructive surgery.
Ultra-high-resolution photon-counting detector CT arthrography of the ankle: a feasibility study
(2023)
This study was designed to investigate the image quality of ultra-high-resolution ankle arthrography employing a photon-counting detector CT. Bilateral arthrograms were acquired in four cadaveric specimens with full-dose (10 mGy) and low-dose (3 mGy) scan protocols. Three convolution kernels with different spatial frequencies were utilized for image reconstruction (ρ\(_{50}\); Br98: 39.0, Br84: 22.6, Br76: 16.5 lp/cm). Seven radiologists subjectively assessed the image quality regarding the depiction of bone, hyaline cartilage, and ligaments. An additional quantitative assessment comprised the measurement of noise and the computation of contrast-to-noise ratios (CNR). While an optimal depiction of bone tissue was achieved with the ultra-sharp Br98 kernel (S ≤ 0.043), the visualization of cartilage improved with lower modulation transfer functions at each dose level (p ≤ 0.014). The interrater reliability ranged from good to excellent for all assessed tissues (intraclass correlation coefficient ≥ 0.805). The noise levels in subcutaneous fat decreased with reduced spatial frequency (p < 0.001). Notably, the low-dose Br76 matched the CNR of the full-dose Br84 (p 0.999) and superseded Br98 (p < 0.001) in all tissues. Based on the reported results, a photon-counting detector CT arthrography of the ankle with an ultra-high-resolution collimation offers stellar image quality and tissue assessability, improving the evaluation of miniscule anatomical structures. While bone depiction was superior in combination with an ultra-sharp convolution kernel, soft tissue evaluation benefited from employing a lower spatial frequency.