Institut für Sportwissenschaft
Refine
Has Fulltext
- yes (61) (remove)
Is part of the Bibliography
- yes (61)
Year of publication
Document Type
- Journal article (61)
Language
- English (61) (remove)
Keywords
- endurance (6)
- physical activity (6)
- wearable (5)
- adolescents (4)
- athletes (4)
- children (4)
- performance (4)
- SWOT (3)
- aerobic fitness (3)
- cardiorespiratory fitness (3)
Athletes adapt their training daily to optimize performance, as well as avoid fatigue, overtraining and other undesirable effects on their health. To optimize training load, each athlete must take his/her own personal objective and subjective characteristics into consideration and an increasing number of wearable technologies (wearables) provide convenient monitoring of various parameters. Accordingly, it is important to help athletes decide which parameters are of primary interest and which wearables can monitor these parameters most effectively. Here, we discuss the wearable technologies available for non-invasive monitoring of various parameters concerning an athlete's training and health. On the basis of these considerations, we suggest directions for future development. Furthermore, we propose that a combination of several wearables is most effective for accessing all relevant parameters, disturbing the athlete as little as possible, and optimizing performance and promoting health.
In this study, we tested the hypothesis that breathing hyperoxic air (F\(_{in}\)O\(_2\) = 0.40) while exercising in a hot environment exerts negative effects on the total tissue level of haemoglobin concentration (tHb); core (T\(_{core}\)) and skin (T\(_{skin}\)) temperatures; muscle activity; heart rate; blood concentration of lactate; pH; partial pressure of oxygen (P\(_a\)O\(_2\)) and carbon dioxide; arterial oxygen saturation (S\(_a\)O\(_2\)); and perceptual responses. Ten well-trained male athletes cycled at submaximal intensity at 21°C or 33°C in randomized order: first for 20 min while breathing normal air (FinO\(_2\) = 0.21) and then 10 min with F\(_{in}\)O\(_2\) = 0.40 (HOX). At both temperatures, S\(_a\)O\(_2\) and P\(_a\)O\(_2\), but not tHb, were increased by HOX. Tskin and perception of exertion and thermal discomfort were higher at 33°C than 21°C (p < 0.01), but independent of F\(_{in}\)O\(_2\). T\(_{core}\) and muscle activity were the same under all conditions (p > 0.07). Blood lactate and heart rate were higher at 33°C than 21°C. In conclusion, during 30 min of submaximal cycling at 21°C or 33°C, T\(_{core}\), T\(_{skin}\) and T\(_{body}\), tHb, muscle activity and ratings of perceived exertion and thermal discomfort were the same under normoxic and hyperoxic conditions. Accordingly, breathing hyperoxic air (F\(_{in}\)O\(_2\) = 0.40) did not affect thermoregulation under these conditions.
Purpose:
The aim of the study was to evaluate the mucosal immune function and circadian variation of salivary cortisol, Immunoglobin-A (sIgA) secretion rate and mood during a period of high-intensity interval training (HIIT) compared to long-slow distance training (LSD).
Methods:
Recreational male runners (n = 28) completed nine sessions of either HIIT or LSD within 3 weeks. The HIIT involved 4 × 4 min of running at 90–95% of maximum heart rate interspersed with 3 min of active recovery while the LSD comprised of continuous running at 70–75% of maximum heart rate for 60–80 min. The psycho-immunological stress-response was investigated with a full daily profile of salivary cortisol and immunoglobin-A (sIgA) secretion rate along with the mood state on a baseline day, the first and last day of training and at follow-up 4 days after the last day of training. Before and after the training period, each athlete's running performance and peak oxygen uptake (V·O\(_{2peak}\)) was determined with an incremental exercise test.
Results:
The HIIT resulted in a longer time-to-exhaustion (P = 0.02) and increased V·O\(_{2peak}\) compared to LSD (P = 0.01). The circadian variation of sIgA secretion rate showed highest values in the morning immediately after waking up followed by a decrease throughout the day in both groups (P < 0.05). With HIIT, the wake-up response of sIgA secretion rate was higher on the last day of training (P < 0.01) as well as the area under the curve (AUC\(_{G}\)) higher on the first and last day of training and follow-up compared to the LSD (P = 0.01). Also the AUC\(_{G}\) for the sIgA secretion rate correlated with the increase in V·O\(_{2peak}\) and running performance. The AUC\(_{G}\) for cortisol remained unaffected on the first and last day of training but increased on the follow-up day with both, HIIT and LSD (P < 0.01).
Conclusion:
The increased sIgA secretion rate with the HIIT indicates no compromised mucosal immune function compared to LSD and shows the functional adaptation of the mucosal immune system in response to the increased stress and training load of nine sessions of HIIT.
Background:
Sit-to-stand height-adjustable desks (HAD) may promote workplace standing, as long as workers use them on a regular basis. The aim of this study was to investigate (i) how common HAD in German desk-based workers are, and how frequently HADs are used, (ii) to identify sociodemographic, health-related, and psycho-social variables of workday sitting including having a HAD, and (iii) to analyse sociodemographic, health-related, and psycho-social variables of users and non-users of HADs.
Methods:
A cross-sectional sample of 680 participants (51.9% men; 41.0 ± 13.1 years) in a desk-based occupation was interviewed by telephone about their occupational sitting and standing proportions, having and usage of a HAD, and answered questions concerning psycho-social variables of occupational sitting. The proportion of workday sitting was calculated for participants having an HAD (n = 108) and not-having an HAD (n = 573), as well as for regular users of HAD (n = 54), and irregular/non-users of HAD (n = 54). Linear regressions were conducted to calculate associations between socio-demographic, health-related, psychosocial variables and having/not having an HAD, and the proportion of workday sitting. Logistic regressions were executed to examine the association of mentioned variables and participants’ usage of HADs.
Results:
Sixteen percent report that they have an HAD, and 50% of these report regular use of HAD. Having an HAD is not a correlate of the proportion of workday sitting. Further analysis restricted to participants having available a HAD highlights that only the ‘perceived advantages of sitting less’ was significantly associated with HAD use in the fully adjusted model (OR 1.75 [1.09; 2.81], p < 0.05).
Conclusions:
The present findings indicate that accompanying behavioral action while providing an HAD is promising to increase the regular usage of HAD. Hence, future research needs to address the specificity of behavioral actions in order to enhance regular HAD use, and needs to give more fundamental insights into these associations.
Purpose: Research dealing with ischemic preconditioning (IPC) has primarily focused on variables associated to endurance performance with little research about the acute responses of IPC on repeated multidirectional running sprint performance. Here we aimed to investigate the effects of IPC of the arms and the legs on repeated running sprint performance with changes-of-direction (COD) movements.
Methods: Thirteen moderately-to-well-trained team-sport athletes (7 males; 6 females; age: 24 ± 2 years, size: 175 ± 8 cm, body mass: 67.9 ± 8.1 kg) performed 16 × 30 m all-out sprints (15 s rest) with multidirectional COD movements on a Speedcourt\(^{©}\) with IPC (3 × 5 min) of the legs (IPC\(_{leg}\); 240 mm Hg) or of the arms (remote IPC: IPC\(_{remote}\); 180–190 mm Hg) 45 min before the sprints and a control trial (CON; 20 mm Hg).
Results: The mean (±SD) time for the 16 × 30 m multidirectional COD sprints was similar between IPC\(_{leg}\) (Mean t: 16.0 ± 1.8 s), IPC\(_{remote}\) (16.2 ± 1.7 s), and CON (16.0 ± 1.6 s; p = 0.50). No statistical differences in oxygen uptake (mean difference: 0%), heart rate (1.1%) nor muscle oxygen saturation of the vastus lateralis (4.7%) and biceps brachii (7.8%) between the three conditions were evident (all p > 0.05).
Conclusions: IPC (3 × 5 min) of the legs (220 mm Hg) or arms (180–190 mm Hg; remote IPC) applied 45 min before 16 × 30 m repeated multidirectional running sprint exercise does not improve sprint performance, oxygen uptake, heart rate nor muscle oxygen saturation of the vastus lateralis muscle when compared to a control trial.
The aim of this pilot study was to analyze the off-training physical activity (PA) profile in national elite German U23 rowers during 31 days of their preparation period. The hours spent in each PA category (i.e., sedentary: <1.5 metabolic equivalents (MET); light physical activity: 1.5–3 MET; moderate physical activity: 3–6 MET and vigorous intense physical activity: >6 MET) were calculated for every valid day (i.e., >480 min of wear time). The off-training PA during 21 weekdays and 10 weekend days of the final 11-week preparation period was assessed by the wrist-worn multisensory device Microsoft Band II (MSBII). A total of 11 rowers provided valid data (i.e., >480 min/day) for 11.6 week days and 4.8 weekend days during the 31 days observation period. The average sedentary time was 11.63 ± 1.25 h per day during the week and 12.49 ± 1.10 h per day on the weekend, with a tendency to be higher on the weekend compared to weekdays (p = 0.06; d = 0.73). The average time in light, moderate and vigorous PA during the weekdays was 1.27 ± 1.15, 0.76 ± 0.37, 0.51 ± 0.44 h per day, and 0.67 ± 0.43, 0.59 ± 0.37, 0.53 ± 0.32 h per weekend day. Light physical activity was higher during weekdays compared to the weekend (p = 0.04; d = 0.69). Based on our pilot study of 11 national elite rowers we conclude that rowers display a considerable sedentary off-training behavior of more than 11.5 h/day.
The aim of the study was to evaluate the reliability and validity of cardiorespiratory and metabolic variables, that is, peak oxygen uptake (V'O\(_{2peak}\)) and heart rate (HR\(_{peak}\)), obtained from an agility‐like incremental exercise test for team sport athletes. To investigate the test–retest reliability, 25 team sport athletes (age: 22 ± 3 years, body mass: 75 ± 7 kg, height: 182 ± 6 cm) performed an agility‐like incremental exercise test on the SpeedCourt (SC) system incorporating multidirectional change‐of‐direction (COD) movements twice. For each step of the incremental SC test, the athletes covered a 40‐m distance interspersed with a 10‐sec rest period. Each 40 m distance was split into short sprints (2.25–6.36 m) separated by multidirectional COD movements (0°–180°), which were performed in response to an external visual stimulus. All performance and physiological data were validated with variables obtained from a ramp‐like treadmill and Yo‐Yo intermittent recovery level 2 test (Yo‐Yo IR2). The incremental SC test revealed high test–retest reliability for the time to exhaustion (ICC = 0.85, typical error [TE] = 0.44, and CV% = 3.88), V'O\(_{2peak}\), HR\(_{peak}\), ventilation, and breathing frequency (ICC = 0.84, 0.72, 0.89, 0.77, respectively). The time to exhaustion (r = 0.50, 0.74) of the incremental SC test as well as the peak values for V'O\(_{2}\) (r = 0.59, 0.52), HR (r = 0.75, 0.78), ventilation (r = 0.57, 0.57), and breathing frequency (r = 0.68, 0.68) were significantly correlated (P ≤ 0.01) with the ramp‐like treadmill test and the Yo‐Yo IR2, respectively. The incremental SC test represents a reliable and valid method to assess peak values for V'O\(_{2}\) and HR with respect to the specific demand of team sport match play by incorporating multidirectional COD movements, decision making, and cognitive components.