540 Chemie und zugeordnete Wissenschaften
Refine
Has Fulltext
- yes (15)
Is part of the Bibliography
- yes (15)
Year of publication
Document Type
- Doctoral Thesis (14)
- Journal article (1)
Keywords
- Aminosäuren (15) (remove)
The stability of Trp in pure solutions and in parenteral AA formulations was evaluated with regard to typically used manufacturing processes, storage conditions and primary packaging. Therefore, thorough stability studies on Trp solutions were conducted beforehand. The applied stressing method, i.e. steam sterilization by autoclave, are chemically seen relatively mild but showed to be efficient to induce Trp degradation in the presence of oxygen. Subsequent identification, separation and characterization were challenging due to similar substance properties, numerous stereoisomers and pairs of diastereomers found amongst them. However, the identified o-aminoacetophenone compounds, Kyn and NFK, are associated with photo reactivity and have photo-oxidizing properties. Thus, best possible protection from UV-light, together with strict oxygen expulsion, are the most important criteria to impede Trp degradation after autoclaving.
The identification of Trp degradation products was assisted by the compilation of a substance library, which included manifold reported and chemically plausible Trp degradation substances. The substances were classified for priority and their early or late-stage occurrence. The large number of possible substances and stereoisomers was narrowed down with the information retrieved from LC-UV/MS experiments. However, final identification was achieved by the synthesis of proposed substances as references. The following eight substances were characterized as Trp degradation substances: Kyn, NFK and three pairs of diastereomers R,R/R,S DiOia, R,R/R,S Oia and cis/trans PIC. Fig. 33 shows the proposed degradation pathway and demonstrates the close chemical relationship, which may be an explanation for the conversion of some substances into each other during the storage period. The proposed pathway brings together the results of different Trp stability and stressing studies, respectively [89, 94, 97, 98, 103, 133]. To our knowledge, the simultaneous formation of the identified degradation substances has not been reported before and especially not under the stressing conditions applied.
The application of a traditional RP-HPLC method was compared to two developed IP-HPLC methods and a RP-HPLC methods using a modified perfluorinated column. Orthogonal analyses methods and especially the combination of UV and MS detection are necessary in order to indicate potentially undetected degradation substances. Main evaluation criteria were the separation performance, analyses time, reproducibility and feasibility. The best results upon assessment of all Trp degradation products, in both; pure Trp solutions and pharmaceutical formulations, were obtained by a traditional RP-HPLC. The optimized method was validated according to ICH guidelines Q2(R1) and meets the criteria of a stability-indicating HPLC-UV method. The validated method has a sufficient separation performance with an adequate selectivity indicating the Trp degradation substances next to each other and next to other AAs in finished pharmaceutical formulations.
The detailed knowledge of Trp degradation and the method presented may be transferred practically to the pharmaceutical industry processing Trp-containing products. In general, the findings might contribute to the quality management of such pharmaceutical products during
manufacturing and storage. Additionally, the study results provide basic information for the establishment of an impurity consideration following the ICH guidelines Q3B (R2) (impurities in new drug products) for products containing Trp. However, further development of the method applying more sophisticated detectors or more potent HPLC techniques like e.g. UHPLC and the implication of more sensitive (MS) detectors like ToF-MS would be advantageous with regard to economic and practical aspects.
The impurity profiling of pharmaceutical ingredients can oppose many challenges. The best part of active pharmaceutical ingredients (APIs) and the related substances are detectable by UV detection, a very common detection principle. However, if an API lacks a suitable chromophore other means of detection are necessary. The corona charged aerosol detector (CAD) is a detector capable of detecting substances independent of their chemical structure. This “universal” detector has only one limitation: The analyte has to have a sufficiently low vapor pressure. Another important challenge that comes often together with the lack of a chromophore concerns the separation. These substances (e.g. most amino acids and derivatives) often contain structures that make them difficult to retain on conventional reversed phase columns.
Possible solutions to overcome these challenges, like the application of the CAD and the benefit of so-called mixed-mode stationary phases in impurity profiling for pharmacopoeial purposes were explored in this work. The related substances analyzed in this thesis comprise amino acids, inorganic ions, bisphosphonic acids, basic and acidic derivatives of amino acids (esters and amides).
The successful development and validation of mixed-mode liquid chromatography methods with CAD detection for carbocisteine and ibandronate sodium might help to increase the acceptance of this versatile detector in the pharmaceutical industry and in official authorities dealing with the determination of related substances.
The combination of UV and CAD detection proved very useful during the analysis of Bicisate. Most of the related substances and some unidentified impurities were detectable by CAD whereas a synthesis by-product, a semi-volatile ester, was only detectable in the UV trace. The simple combination covers all relevant impurities in a single analysis.
Two truly orthogonal methods regarding separation and detection for the enantiomeric purity of magnesium-L-aspartate helped to find the reason for elevated D aspartic acid content in the drug substance. A very quick and sensitive indirect separation using the OPA derivatization with NAC was developed as a powerful screening tool, whereas the direct separation of D- and L-CBQCA-Asp derivatives confirmed the results. Both methods were optimized in order to do without substances mentioned on the REACH list, like sodium tetraborate which is very frequently applied in standard derivatization protocols and CE separations.
The importance of orthogonal detection principles in the determination of related substances of amino acids was discussed in a review article dealing with the revision of amino acid monographs in the Ph. Eur..
Das Ziel vorliegender Arbeit war die Entwicklung einer HPLC-MS(/MS)-Methode, die im Rahmen der pharmazeutischen Qualitätskontrolle zur direkten Quantifizierung von Aminosäuren (AS) in Infusionslösungen angewendet werden kann. Die Zielset-zung schloss eine Validierung innerhalb der für die Zweckbestimmung vorgesehenen Grenzen ein. Im Rahmen der Methodenentwicklung wurde das ESI-MS/MS-Fragmentierungs-muster von 21 Aminosäuren, von 20 stabil-isotopenmarkierten Aminosäuren, die als interne Standards verwendet wurden, sowie von einigen weiteren Substanzen bestimmt. Nach Kenntnis von Precursor- und Produktionen erstellte man eine SRM-Methode zur spezifischen MS/MS-Analyse. Dabei wurden durch das jeweilige Frag-mentierungsmuster bedingte Interferenzen bei den zu untersuchenden Aminosäuren bestimmt, die bei der zu erarbeitenden HPLC-MS-Methode beachtet werden mussten. Die Methodenentwicklung zur HPLC-MS-Analytik von underivatisierten AS umfasste mit der RP-HPLC unter Verwendung eines Ionenpaarreagenzes (IP) und der hydrophilen Interaktionschromatographie (HILIC) zwei verschiedene chromatographi-sche Ansätze. Bei der Anwendung der RP-HPLC ergaben sich Probleme. Die Verwendung eines IP, im vorliegenden Fall TDFHA (Tridecafluorheptansäure), führte zu langen Equilibrierungs-, Re-Equilibrierungs- und Spülzeiten und damit bei zwar relativ kurzer HPLC-Laufzeit zu einem aber insgesamt hohen Zeitaufwand. Gleich-zeitig war die LC-MS-Anlage auf diese Anwendung fixiert, da das Ionenpaarreagenz das Gerät stark verschmutzte und dadurch andere Analysen erheblich störte. Zudem waren die Retentionszeiten der Analyten trotz langer Equilibrierungszeiten schlecht reproduzierbar, so dass eine solche Methode im Rahmen der pharmazeutischen Qualitätskontrolle schwer validierbar wäre. Weiterführende Untersuchungen erfolgten daher nicht. In nachfolgenden Studien mit der HILIC wurden verschiedene Einflussparameter (Anteil organischer Phase im Fließmittel, pH-Wert des Fließmittels, Temperatur der Säule, Pufferkonzentration im Fließmittel, Gradientenelution) auf die Trennung der AS an einer ZIC®-HILIC-Säule untersucht. Durch Optimierung der Parameter wurde so eine HILIC-HPLC-Methode entwickelt, bei der 21 AS und 20 ihrer isotopen-markierten Referenz-AS innerhalb von 20 min eluierten. Diejenigen AS, bei denen im Rahmen der Fragmentierungsstudien Interferenzen aufgrund gleicher bzw. ähnlicher Massen der Precursor- bzw. Produktionen aufgetreten waren, wurden chroma-tographisch getrennt. Gleichzeitig hat sich die SIM-Analyse als anwendbar erwiesen. Die Anwendung des spezifischeren SRM-Modus und damit der Tandem-Massenspektrometrie war nicht erforderlich. Im Rahmen der nachfolgenden Studien zur Validierung ergab sich, dass die entwickelte Methode über einen weiten Bereich eine lineare Abhängigkeit zwischen Konzentrations- und Messwerten zeigte. Für drei der 21 AS (NAcCys, NAcTyr, Pro) wurde die quadratische Regression mit dem Anpassungstest nach Mandel als geeig-neteres Regressionsmodell ermittelt. Bei Untersuchungen zur Wiederfindung wurde ein Einfluss der Matrix-Lösung der Infusionslösung festgestellt, der zu Abweichungen hinsichtlich des Quotienten AreaAS / AreaIS führte, so dass eine Quantifizierung innerhalb der geforderten Grenzen bei Kalibrierung über reine Standardlösungen nicht möglich war. Die Validierung wurde daher nachfolgend in der Matrixlösung durchgeführt. Dabei wurde gezeigt, dass mit der entwickelten HILIC-HPLC-MS-Methode Aminosäuren in Infusionslösungen mit hoher Präzision und Richtigkeit bestimmt werden können. Neun der 21 untersuchten AS konnten im Bereich von 30% - 350%, zehn weitere im Bereich von 50% - 350% innerhalb der zur Gehaltsbestimmung von pharmazeutischen Formulierungen vorgeschriebenen Grenzen (Wiederfindung Einzelbestimmung: 98% -102.0%, Mittelwert einer Dreifachbestimmung: 98.5% – 101.5%) quantifiziert werden. Für His und Phe gelang allerdings keine Quantifizierung innerhalb der Akzeptanzkriterien, wobei der Grund hierfür in weiteren Studien geklärt werden müsste. Mit der entwickelten Methode ist damit eine gleichzeitige Quantifizierung verschiedener AS-Infusionslösungsformulierungen möglich, die sich bei gleicher Matrix in der Konzentration an AS unterscheiden. Beispielsweise seien hier die Formulierungen „Aminoplasmal® E 5% / 10% /15%“ genannt, die mit der validierten Methode erfassbar sind. Die Probenvorbereitung beschränkt sich dabei auf den Zusatz der IS-Formulierung zur Infusionslösung und einen Verdünnungsschritt. Die Quanti-fizierung erfolgt über eine 5-Punkt-Kalibriergerade, die aus einer AS- und IS-Standardmischung, nach Zusatz der einfach herzustellenden Elektrolyt-Matrix, erstellt wird. Die Analysenzeit der HPLC-MS-Methode beträgt einschließlich Equilibrie-rungszeit 35 min und ist damit deutlich kürzer als die 120 min, die bei der nach wie vor zur AS-Analytik allgemein gebräuchlichen Ionenaustauschchromatographie mit Ninhydrin-Nachsäulenderivatisierung anzusetzen sind.
Das Ziel der vorliegenden Arbeit war die Klärung der Fragestellung, ob sich die quantitative NMR-Spektroskopie zur Bestimmung von Identität, Reinheit und Gehalt von Arzneistoffen eignet, und wie sich Präzision und Empfindlichkeit dieser Methode im Vergleich zu etablierten chromatographischen Verfahren verhalten. Die quantitative Untersuchung der drei strukturell jeweils verwandten Mehrkomponentengemische Codergocrinmesilat, Clomifencitrat und Flupentixoldihydrochlorid bewies eindrucksvoll die Eignung der 1H-NMR-Spektroskopie als orthogonale, analytische Messmethode im Vergleich zu validierten HPLC-Arzneibuchmethoden. Die im Rahmen einer Validierung der 1H-NMR-Methode ermittelten Ergebnisse erfüllten bezüglich Präzision und Richtigkeit die an eine im pharmazeutischen Bereich eingesetzte analytische Methode gestellten Anforderungen; zudem wurden weitere Prüfparameter wie Selektivität, Linearität, Robustheit und Stabilität verifiziert. Externe-Standard-Experimente wie "Zwei-Röhrchen-Methode" und ERETIC-Verfahren bestätigten die quantitativen Ergebnisse der Internen Standardisierung; jedoch wurde hier -- insbesondere für die ERETIC-Technik -- eine höhere Fehleranfälligkeit und somit eine größere Streuung der Einzelergebnisse beobachtet. Am Beispiel von Codergocrinmesilat und Flupentixoldihydrochlorid konnte zudem die Eignung anderer NMR-aktiver Kerne wie 13C und 19F für die quantitative Analyse von komplexen Substanzgemischen aufgezeigt werden. Das Potential der 1H-NMR-Spektroskopie für die Reinheitsprüfung von Arzneistoffen wurde am Beispiel der Aminosäure L-Alanin aufgezeigt. Die zu erwartenden Verunreinigungen Glutamin-, Asparagin-, Äpfel- und Fumarsäure konnten im Gegensatz zu den "veralteten" Prüfmethoden des Europäischen Arzneibuches eindeutig identifiziert und quantifiziert werden; mit einer Bestimmungsgrenze von <= 0.03% wurden die Vorgaben der ICH-Richtlinie Q3A(R2) erfüllt. Die deutliche Übereinstimmung der NMR-spektroskopisch ermittelten Ergebnisse einer quantitativ untersuchten Alanin-Modellmischung mit einer für den Routinebetrieb geeigneten HPLC-Methode unter Einsatz verschiedener Detektoren wie CAD, NQAD, ELSD und MS, sowie der Vergleich wichtiger Prüfparameter wie Linearität und Nachweisgrenze bestätigten die Eignung der 1H-NMR-Spektroskopie im Rahmen der routinemäßig durchgeführten Qualitätskontrolle. Die Aufdeckung von Arzneimittelfälschungen mit Hilfe der NMR-Spektroskopie wurde im Rahmen dieser Arbeit anhand der zwei aktuellen Fallbeispiele Heparin und Glycerin näher untersucht. Die in Zusammenhang mit dem Heparin-Skandal verantwortliche Kontaminante OSCS konnte neben Dermatansulfat und weiteren natürlich vorkommenden Glykosaminoglykan-Verunreinigungen im 1H-NMR-Spektrum eindeutig identifiziert und auf 0.1% OSCS bzw. 0.5% Dermatansulfat begrenzt werden. Eine präzise und richtige quantitative Bestimmung der beiden Glykosaminoglykane wurde über die N-Acetyl-Resonanzen mit Hilfe der Signalhöhenbestimmung und dem Standard-Additionsverfahren ermöglicht; deutliche Abweichungen vom "wahren" Gehalt wurden hingegen, bedingt durch starke Signalüberlagerungen, nach Flächenvergleich beobachtet. Weitere Verunreinigungen, insbesondere Lösungsmittelrückstände, die während des Extraktions- und Reinigungsprozesses des Heparins eingesetzt werden, konnten ebenfalls über charakteristische Resonanzen identifiziert und mit Hilfe der Internen-Standard-Methode quantitativ erfasst werden. Eine umfangreiche Untersuchung von 145 Heparin-API-Mustern mittels NMR-Spektroskopie und weiteren, neuentwickelten Verfahren wie HPLC, CE, IR- und Raman-Spektroskopie konnte die Eignung der entwickelten 1H-NMR-Methode bestätigen. Potentielle Glycerin-Kontaminanten wie Diethylenglycol und Ethylenglycol konnten ebenso wie eine weitere, natürlich vorkommende Verunreinigung, Propylenglycol, mittels 1H- und 13C-NMR-Spektroskopie identifiziert und quantifiziert werden. Beide Methoden erfüllten die in der USP beschriebenen Anforderungen, die für pharmazeutisch eingesetztes Glycerin jeweils höchstens 0.1% Diethylenglycol bzw. Ethylenglycol erlaubt. Während die quantitative Reinheitsprüfung beim Einsatz der 1H-NMR-Spektroskopie mit einer Messdauer im Bereich von etwa 30 min für den Routineeinsatz geeignet ist, ist die entwickelte quantitative 13C-NMR-Methode beim Einsatz von Spektrometern geringer Magnetfeldstärke aufgrund einer geringen Nachweisempfindlichkeit und der NOE-Problematik für den Routinebetrieb nur bedingt anwendbar. Abschließend kann zusammengefasst werden, dass die untersuchten Beispiele die NMR-Spektroskopie als in hohem Maße geeignet für die quantitative Analyse von Arzneimitteln ausweisen.
The work presented in this thesis was mainly targeted at exploring the capabilities of evaporation based LC detectors as well as further alternatives for the control of impurities in substances not exhibiting a suitable chromophore for UV-detection. In the course of the work carried out, several new methods for the identification, impurities control and composition testing of APIs were elaborated. An evaporation based detector that entered into the field of pharmaceutical analysis in the recent years was the Evaporative Light Scattering Detector (ELSD). However, non-reproducible spikes were reported when injecting concentrated test solutions as they are usually required for the control of impurities. The reasons, for the appearance of these spikes as well as possibilities for their avoidance were explored in a systematic study. Moreover, the dependence of the detector sensitivity on different eluent composition, eluent flow-rate and ELSD settings was investigated. In the course of the revision of the Ph.Eur. monographs for aspartic acid and alanine, a C18 reversed phase ion-pair LC method using 1 mmol/L of perfluoroheptanoic acid as an ion-pair reagent and a charged aerosol detector (CAD) was developed and fully validated for the purity control of Asp. The method was capable of separating the organic acids and major amino acids known to occur as process related impurities. With a slight modification, the method was also applicable for the purity control of Ala. Based on the developed LC-CAD method for the impurity control of alanine, a comparative study of the performance characteristics of different evaporation based LC detectors, i.e. ELSD, CAD and the recently developed Nano Quantity Analyte Detector (NQAD) was carried out. Additionally, an MS detector and qNMR were included in this study. It was found that the control of impurities in Alanine at an ICH conform level could be ensured using LC coupled to CAD, MSD and NQAD detection as well as by the use of qNMR. In terms of performance, prize and ease of use CAD and NQAD were found to be the most suitable alternatives. In terms of repeatability and sensitivity, the CAD appeared slightly superior to the NQAD. The quality of streptomycin sulfate is not sufficiently controlled by the current Ph.Eur. monograph in that an appropriate test for the control of the related substances is missing. A study was carried out to develop a C18 reversed phase ion-pair LC method using pentafluoropropionic acid as an ion-pair reagent and a CAD for the identification and control of the related substances. The developed method allowed the separation of 21 impurities from streptomycin. Moreover, coupling of the method to MS allowed the identification of the separated impurities. The method was shown to be sufficiently sensitive to control the related substances with a disregard limit of 0.1% as it is normally applied in the Ph.Eur. for products derived from fermentation. Currently, the aescin content of horse-chestnut standardized dry extract is determined using a complex and laborious photometric determination. A more selective LC-UV assay determination for beta-aescin has been proposed for the Ph.Eur. draft monograph of horse-chestnut standardized dry extract. Possibilities were explored to further improve the LC-method using detection by CAD. It was demonstrated that by the use of a modified LC-CAD method several problems related to the differences in the UV-response of the various components contained in the active aescin fraction could be eliminated. Moreover the proposed reference standard strategy was reviewed. Eventually, it was demonstrated on the example of two different clusters of pharmacologically active peptides how low energy collision induced dissociation mass spectrometry (low energy CID-MS) can successfully be used for identification testing in pharmacopoeial monographs. In this respect, the combination of a direct confirmation of the molecular mass via the m/z-ratio of the molecule ions with structural sequence information obtained by low energy CID-MS experiments was found to deliver a higher degree of certainty of the identity of a given substance than the set of tests currently described in the monographs. A significant gain in efficiency and throughput and important reduction of the amount of sample consumed during testing were identified as being additional advantages of this approach. Taken together, it could be demonstrated on various examples how recent technological advancements in the field of analytical chemistry can contribute to improve the quality control of APIs.
Kapillarelektrophoretische Reinheitsanalytik verschiedener Arzneistoffe des Europäischen Arzneibuchs
(2011)
Die Kapillarelektophorese (CE), deren Trennprinzip auf der Wanderung geladener Teilchen im elektrischen Feld basiert, ist eine Methode, die in verschiedenen Techniken angewandt werden kann. Sowohl die wässrige Kapillarzonenelektrophorese (CZE) als auch die wasserfreie CE (NACE), aber auch die elektrokinetische Chromatographie mittels Mikroemulsion (MEEKC) wurden in dieser Arbeit für die Reinheitsanalytik der im Europäischen Arzneibuch beschriebenen Wirkstoffe Ethambutol, Quetiapin, Ephedrin sowie Levodopa und deren jeweils strukturverwandter Substanzen benutzt. Der Wirkstoff Ethambutol wird in der (S,S)-Form verwendet, die im Ph. Eur. 7 als Dihydrochlorid aufgeführt ist. Um eine Trennmethode für (S,S)-Ethambutol, sein Enantiomer und die achirale meso-Verbindung entwickeln zu können, wurden die beiden stereoisomeren Verunreinigungen aus 2-Amino-1-butanol und Diethyloxalat synthetisiert. Zur Trennung dieser drei Ethambutol-Isomere wurde CZE als Methode gewählt. In saurem Phosphatpuffer musste eine hohe Probenkonzentration von 1 mg/ml verwendet werden, um die Substanzen mit UV detektieren zu können (λ: 200 nm). In alkalischem Tetraboratpuffer war das Chromophor dank der freien Elektronenpaare der Stickstoff-Moleküle besser ausgeprägt und die Intensität der Peaks deutlich intensiver. Als chirale Selektoren wurden die nativen α-, β- und γ-Cyclodextine (CDs) und verschiedene derivatisierte β-CDs eingesetzt. Die Methode wurde vielfach in Bezug auf Molarität und pH-Wert der Puffer, Konzentration der verschiedenen chiralen Selektoren, Spannung und Temperatur modifiziert. Jedoch konnte keine Trennung der Stereoisomere erreicht werden. Eine CD-modifizierte MEEKC-Methode wurde herangezogen, um die Racemate der Aminosäuren Dopa, Methyldopa, Tyrosin und Phenylalanin voneinander zu trennen. Dazu wurde eine Mikroemulsion (ME) aus Ethylacetat, SDS, 1-Butanol, Phosphatpuffer, sulf. β-CD und, wenn nötig, aus dem organischen Modifier 2-Propanol eingesetzt. Für jede DL-Aminosäure wurde die Zusammensetzung der ME als auch die Geräteeinstellungen (Spannung, Temperatur) optimiert. Die Trennung von DL-Dopa konnte ohne Zugabe eines organischen Modifiers durchgeführt werden. Auf Grundlage dieser individuellen Methoden wurden zwei CD-modifizierte MEEKC-Methoden entwickelt, mit denen alle vier untersuchten Racemate getrennt werden konnten. Die abschließende Validierung in Bezug auf Wiederholpräzision (Auflösung, Migrationszeiten, Verhältnis der korrigierten Peakflächen und Anzahl der theoretischen Böden) und Detektionsgrenzen zeigte, dass die Methoden präzise Ergebnisse liefern. Die Technik der MEEKC wurde auch zur Trennung von Ephedrin-Derivaten genutzt. Wedig et al. konnten die Racemate von Ephedrin, Pseudoephedrin, N-Methylephedrin und Norephedrin mit einer HDAS-β-CD-modifizierten CZE-Methode in einem Lauf basislinientrennen, indem ein 50 mM Phosphatpuffer, pH 3,0 als HGE eingesetzt wurde. Aus diesem HGE und den organischen Bestandteilen, die zur Trennung der Aminosäuren führten, wurde eine ME hergestellt. Entgegen der Methode von Wedig et al. konnte mittels HDAS-β-CD keine zufriedenstellende Trennleistung erreicht werden. Durch Austausch des chiralen Selektors gegen sulf. β-CD und Modifizierung des Phosphatpuffers in Ionenstärke und pH-Wert konnte für alle vier Epedrin-Derivate eine Basislinientrennung erzielt werden. Diese MEEKC-Methode wurde auf weitere Ephedrin-Derivate angewandt, wodurch das racemische 2-(Dibutylamino)-1-phenyl-1-propanol partiell, die Racemate von Adrenalin, 2-Amino-1-phenylethanol und Diethylnorephedrin vollständig voneinander getrennt werden konnten. Während mit der HDAS-β-CD-modifizierten CZE-Methode alle vier Ephedrin-Derivaten in einem Lauf getrennt werden konnten, hat die MEEKC-Methode den Vorteil mit dem kostengünstigeren sulf. β-CD auszukommen. Schlussendlich wurde eine Reinheitsanalytik von Quetiapin und seinen verwandten Substanzen Quetiapindesethanol, Quetiapin-N-Oxid und Quetiapinlactam entwickelt. Da Quetiapinlactam fast ausschließlich in organischen Lösungsmitteln löslich ist, sollte eine wasserfreie CE-Methode (NACE) eingesetzt werden. Zwar konnte eine Methode entwickelt werden, deren HGE aus Methanol, Acetonitril, Ammoniumacetat und Essigsäure bestand, und mit der Quetiapin und seine drei verwandten Substanzen sehr gut getrennt werden konnten. Allerdings konnte sie aufgrund von Stromabbrüchen nicht validiert werden. Alternativ wurde eine wässrige, gut reproduzierbare CZE-Methode gefunden, deren Elektrolytlösung aus einem 80 mM Phosphatpuffer, pH 4.0 bestand. Aufgrund der Wasserunlöslichkeit von Quetiapinlactam konnten so nur Quetiapin und die Verunreinigungen Quetiapindesethanol und Quetiapin-N-Oxid erfasst werden. Abschließend wurde die CZE-Methode validiert, wodurch die hohe Präzision der ermittelten Werte gezeigt werden konnte.
T~e N,N'-dicrclohexylcarbodiimide-binding proteolipid subumt of the mitochondrial adenosinetriphosphatases (ATP phosphohydrolase, EC 3.6.1.3) of Neurosporacrassa and Saccharomyces cerevisiae were purified from mitochondria incubated with the radioactively labeled inhibitor. The specifically labeled subunit was cleaved with cyanogen bromide and N-bromosuccinimide, and the resultant fragments were separated by gel chromatography in the presence of 80% (vol/vol) formic acid. The N,N'-dicyclohexylcarbodiimide label was recovered in each organism exclusively in a 17-residue fragment. Further analysis by automated solid-phase Edman degrada.ti.on revealed tha~ the bound label was present at only one positIOn, correspondmg to a glutamyl residue. The NN'~ icyc~ohexyl~a~bodiiJ?1~de-'!l0dified glutamyl residue is the ~nly Id~ntIcal aCidic posItIon m both proteins and occurs in the middle of a hydrophobic sequence of about 25 residues.
The main aim of this thesis was the synthesis and structural characterization of penta and hexacoordinate silicon(IV) complexes. In the course of these studies, the neutral pentacoordinate silicon(IV) complexes 38, 39, 43−48, 54 and 55 were prepared. Furthermore, the neutral hexacoordinate silicon(IV) complexes 33−36, 49, 50, 52, 53, 56−62, 63, 64 and 65 were synthesized. All compounds were characterized by elemental analyses, NMR spectroscopy in solution (1H, 13C, 15N, 29Si) and in the solid-state (13C, 15N, 29Si VACP/MAS NMR), as well as single-crystal X-ray diffraction (except 45, 47−49, 52, 53 and 63).
Der erste Teil der vorliegenden Arbeit beschreibt neuartige Synthesen siliciumhaltiger Aminosäuren, ausgehend von Malonsäurediethylester. Weitere Teilschritte dieser Synthesen sind eine biokatalytische enantioselektive Esterspaltung von Malonsäurediethylester-Derivaten mittels Schweineleberesterase und ein Curtius-Abbau. Es wurde in allen Schritten darauf geachtet, kostengünstige und leicht handhabbare Chemikalien zu verwenden, um eine etwaige Produktion der Aminosäuren in einem größeren Maßstab zu ermöglichen. Der zweite Teil der vorliegenden Arbeit widmet sich Versuchen, aus den im vorangehenden Abschnitt beschriebenen Aminosäuren potentielle dipeptidische, siliciumorganische Süßstoffe herzustellen. Diese werden am besten als Aspartam-Analoga beschrieben. Die Charakterisierung der Verbindungen erfolgte durch NMR-Spektroskopie (1H, 13C, 15N, 29Si), Elementaranalysen und gegebenenfalls durch Kristallstrukturnalysen.
The main focus of this thesis was the synthesis and analysis of multifunctional oligopeptides. The study of their non-covalent interactions with various counterparts revealed interesting new results, leading to both methodological and application related progress. The first project of this thesis concentrated on the in-depth analysis of the peptide receptor CBS-Lys-Lys-Phe-NH2 to acquire a better understanding of its binding mode upon complexation with a substrate. In this context it was possible to develop—in cooperation with the group of Prof. Sebastian Schlücker—a direct and label free spectroscopic detection of immobilized compounds which are often found in combinatorial libraries. This new screening method utilizes the advantages of the surface enhanced Raman spectroscopy and allowed for the first time a surface mapping of a single polystyrene bead for the identification of peptides in femtomolar concentrations. Hence, this method allows a very fast and sensitive detection of resin bound compounds. The development of this promising new approach set the starting point for future experiments to enable on-bead library screenings and to investigate the complex formation of immobilized compounds. After the comprehensive analysis of the basic structural features of small peptide receptors in the first part of this thesis, the second big block focused on its in vitro evaluation using biological relevant targets. Therefore, several different modifications of the initial peptide structures were synthesized. These modifications provided a molecular toolkit for the tailor made synthesis of structures individually designed for the respective target. The first tests addressed the interaction with Alzheimer’s related amyloid fibrils. During these experiments, the successful SPPS syntheses of tri- and tetravalent systems were achieved. The comparison of the multivalent form with the corresponding monovalent version was then under special investigations. These concentrated mainly on the interaction with various bacteria strains, as well as with different parasites. To localize the compounds within the organisms, the synthesis of fluorescence labelled versions was achieved. In addition, several compounds were tested by the Institute for Molecular Infection Biology of the University of Würzburg for their antibacterial activity. This thorough evaluation of the biological activity generated precious information about the influence of small structural changes in the peptide receptors. Especially the distinct influence of the multivalency effect and the acquired synthetic skills led to the development of an advanced non-covalent recognition event, as described in the final project of this thesis. The last part of this thesis discussed the development of a novel inhibitor for the serine protease beta-tryptase based on a tailor-made surface recognition event. It was possible to study and analyze the complex interaction with the unique structure of tryptase, that features a tetrameric frame and four catalytic cleavage sites buried deep inside of the hollow structure. However, the point of attack were not the four binding pockets, as mostly described in the literature, but rather the acidic areas around the cleavage sites and at the two circular openings. These should attract peptides with basic residues, which then can block the accessibility to the active sites. A combinatorial library of 216 tetravalent peptide compounds was synthesized to find the best structural composition for the non-covalent inhibition of beta-tryptase. For the screening of the library a new on-bead assay was applied. With this method a simultaneous readout of the total inhibition of all library members was possible, thus allowing a fast and direct investigation of the still resin bound inhibitors. Several additional experiments in solution unveiled the kinetics of the inhibition process. In conclusion, both mono- and multivalent inhibitors interact in a non-destructive and reversible way with the tryptase.