617 Chirurgie und verwandte medizinische Fachrichtungen
Refine
Has Fulltext
- yes (4)
Is part of the Bibliography
- yes (4)
Document Type
- Journal article (4)
Language
- English (4)
Keywords
Revision Arthroplasty Through the Direct Anterior Approach Using an Asymmetric Acetabular Component
(2020)
Despite increasing numbers of primary hip arthroplasties performed through the direct anterior approach (DAA), there is a lack of literature on DAA revision arthroplasty. The present study was performed in order to evaluate outcomes and revision rates after revision through the DAA using an asymmetric acetabular component with optional intra- and extramedullary fixation. In a retrospective cohort study, we analyzed prospectively collected data of 57 patients (61 hips, 43 female, 18 male) who underwent aseptic acetabular component revision through the DAA with the abovementioned implant system between January 2015 and December 2017. The mean follow-up was 40 months (12–56). Survival rates were estimated using the Kaplan–Meier method. All complications were documented and functional outcomes were assessed pre- and postoperatively. Kaplan–Meier analysis revealed an estimated five-year implant survival of 97% (confidence interval CI 87–99%). The estimated five-year survival with revision for any cause was 93% (CI 83–98%). The overall revision rate was 6.6% (n = 4). Two patients had to undergo revision due to periprosthetic infection (3.3%). In one patient, the acetabular component was revised due to aseptic loosening four months postoperatively. Another patient suffered from postoperative iliopsoas impingement and was treated successfully by arthroscopic iliopsoas tenotomy. Two (3.3%) of the revised hips dislocated postoperatively. The mean Harris Hip Score improved from 35 (2–66) preoperatively to 86 (38–100) postoperatively (p < 0.001). The hip joint’s anatomical center of rotation was restored at a high degree of accuracy. Our findings demonstrate that acetabular revision arthroplasty through the DAA using an asymmetric acetabular component with optional intra- and extramedullary fixation is safe and practicable, resulting in good radiographic and clinical midterm results.
Adjuvant Radiotherapy
(2011)
Introduction
The goals of successful bi-compartmental knee arthroplasty are to achieve correct fit and positioning of the implant, while appropriately correcting the mechanical alignment of the leg after surgery. As these requirements are not always reliably fulfilled using off-the-shelf implant systems, newer approaches for bi-compartmental resurfacing have been explored.
Material and methods
In this article we report the radiographic results of 30 patients with anteromedial osteoarthritis (OA) who were treated with a novel patient-specific fixed-bearing bi-compartmental knee resurfacing system using custom-made implants and instruments. Utilizing standardized pre- and postoperative radiographic analyses (based on anterior-posterior and lateral, anterior-posterior weight-bearing full-length radiographs, patella skyline views and preoperative computed tomography (CT) scanning) implant fit and positioning as well as correction of the mechanical axis (hip-knee-ankle angle, HKA) were determined.
Results
On average, HKA was corrected from 173.4 ±3.47° preoperatively to 179.4 ±2.85° postoperatively. The coronal femoro-tibial angle was corrected on average 5.61°. The preoperative tibial slope measured on lateral views was 6.38 ±2.4°, while the average slope in the CT-based planning protocol (iView) was 6.14 ±2.40°. Postoperative lateral tibial slope was determined to be 5.77 ±1.97°. The thickness of the posterior femoral cuts was measured intraoperatively and, in all cases, corresponded well to the targeted thickness of the cuts provided by the iView. The joint line was preserved in all cases and the average Insall-Salvati index was 1.078 ±0.11 pre- and 1.072 ±0.11 postoperatively. The fit of the implant components measured by over- or underhang was excellent throughout (< 1.01 mm).
Conclusions
Custom-made bicompartmental knee arthroplasty can ensure optimized fitting and positioning of the implant with restoration of the leg axis. These implants could be considered as an alternative primary solution for knee surgeons treating bi-compartmental disease.
Background
The key for successful delivery in minimally-invasive hip replacement lies in the exact knowledge about the surgical anatomy. The minimally-invasive direct anterior approach to the hip joint makes it necessary to clearly identify the tensor fasciae latae muscle in order to enter the Hueter interval without damaging the lateral femoral cutaneous nerve. However, due to the inherently restricted overview in minimally-invasive surgery, this can be difficult even for experienced surgeons.
Methods and Surgical Technique
In this technical note, we demonstrate for the first time how to use the tensor fasciae latae perforator as anatomical landmark to reliably identify the tensor fasciae latae muscle in orthopaedic surgery. Such perforators are used for flaps in plastic surgery as they are constant and can be found at the lateral third of the tensor fasciae latae muscle in a direct line from the anterior superior iliac spine.
Conclusion
As demonstrated in this article, a simple knowledge transfer between surgical disciplines can minimize the complication rate associated with minimally-invasive hip replacement.