• Treffer 3 von 3
Zurück zur Trefferliste

Fast MR Imaging of the paediatric abdomen with CAIPIRINHA-accelerated T1w 3D FLASH and with high-resolution T2w HASTE: a study on image quality

Zitieren Sie bitte immer diese URN: urn:nbn:de:bvb:20-opus-149217
  • The aim of this study was to explore the applicability of fast MR techniques to routine paediatric abdominopelvic MRI at 1.5 Tesla. "Controlled Aliasing in Parallel Imaging Results in Higher Acceleration-" (CAIPIRINHA-) accelerated contrast-enhanced-T1w 3D FLASH imaging was compared to standard T1w 2D FLASH imaging with breath-holding in 40 paediatric patients and to respiratory-triggered T1w TSE imaging in 10 sedated young children. In 20 nonsedated patients, we compared T2w TIRM to fat-saturated T2w HASTE imaging. Two observers performed anThe aim of this study was to explore the applicability of fast MR techniques to routine paediatric abdominopelvic MRI at 1.5 Tesla. "Controlled Aliasing in Parallel Imaging Results in Higher Acceleration-" (CAIPIRINHA-) accelerated contrast-enhanced-T1w 3D FLASH imaging was compared to standard T1w 2D FLASH imaging with breath-holding in 40 paediatric patients and to respiratory-triggered T1w TSE imaging in 10 sedated young children. In 20 nonsedated patients, we compared T2w TIRM to fat-saturated T2w HASTE imaging. Two observers performed an independent and blinded assessment of overall image quality. Acquisition time was reduced by the factor of 15 with CAIPIRINHA-accelerated T1w FLASH and by 7 with T2w HASTE. With CAIPIRINHA and with HASTE, there were significantly less motion artefacts in nonsedated patients. In sedated patients, respiratory-triggered T1w imaging in general showed better image quality. However, satisfactory image quality was achieved with CAIPIRINHA in two sedated patients where respiratory triggering failed. In summary, fast scanning with CAIPIRINHA and HASTE presents a reliable high quality alternative to standard sequences in paediatric abdominal MRI. Paediatric patients, in particular, benefit greatly from fast image acquisition with less breath-hold cycles or shorter sedation.zeige mehrzeige weniger

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Autor(en): Mengxia Li, Beate Winkler, Thomas Pabst, Thorsten Bley, Herbert Köstler, Henning Neubauer
URN:urn:nbn:de:bvb:20-opus-149217
Dokumentart:Artikel / Aufsatz in einer Zeitschrift
Institute der Universität:Medizinische Fakultät / Kinderklinik und Poliklinik
Medizinische Fakultät / Klinik und Poliklinik für Strahlentherapie
Sprache der Veröffentlichung:Englisch
Titel des übergeordneten Werkes / der Zeitschrift (Englisch):Gastroenterology Research and Practice
Erscheinungsjahr:2015
Band / Jahrgang:2015
Heft / Ausgabe:693654
Originalveröffentlichung / Quelle:Gastroenterology Research and Practice Volume 2015, Article ID 693654 (2015). DOI: 10.1155/2015/693654
DOI:https://doi.org/10.1155/2015/693654
Allgemeine fachliche Zuordnung (DDC-Klassifikation):6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Freie Schlagwort(e):Dixon; VIBE; breath-hold; clinical application; gadoxetic acid; standard
Datum der Freischaltung:27.11.2018
Lizenz (Deutsch):License LogoCC BY: Creative-Commons-Lizenz: Namensnennung