• Treffer 3 von 3
Zurück zur Trefferliste

Data on pure tin by Positron Annihilation Lifetime Spectroscopy (PALS) acquired with a semi-analog/digital setup using DDRS4PALS

Zitieren Sie bitte immer diese URN: urn:nbn:de:bvb:20-opus-177698
  • Positron annihilation lifetime spectroscopy (PALS) provides a powerful technique for non-destructive microstructure investigations in a broad field of material classes such as metals, semiconductors, polymers or porous glasses. Even though this method is well established for more than five decades, no proper standardization for the used setup configuration and subsequent data processing exists. Eventually, this could lead to an insufficiency of data reproducibility and avoidable deviations. Here we present experimentally obtained and simulatedPositron annihilation lifetime spectroscopy (PALS) provides a powerful technique for non-destructive microstructure investigations in a broad field of material classes such as metals, semiconductors, polymers or porous glasses. Even though this method is well established for more than five decades, no proper standardization for the used setup configuration and subsequent data processing exists. Eventually, this could lead to an insufficiency of data reproducibility and avoidable deviations. Here we present experimentally obtained and simulated data of positron lifetime spectra at various statistics measured on pure tin (4N-Sn) by using a semi-analog/digital setup, where the digital section consists of the DRS4 evaluation board, “Design and performance of the 6 GHz waveform digitizing chip DRS4” [1]. The analog section consists of nuclear instrument modules (NIM), which externally trigger the DRS4 evaluation board to reduce the digitization and, thus, increase the acquisition efficiency. For the experimentally obtained lifetime spectra, 22Na sealed in Kapton foil served as a positron source, whereas 60Co was used for the acquisition of the prompt spectrum, i.e. the quasi instrument response function. Both types of measurements were carried out under the same conditions. All necessary data and information regarding the data acquisition and data reduction are provided to allow reproducibility by other research groups.zeige mehrzeige weniger

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Autor(en): Danny Petschke, Ricardo Helm, Torsten E.M. Staab
URN:urn:nbn:de:bvb:20-opus-177698
Dokumentart:Artikel / Aufsatz in einer Zeitschrift
Institute der Universität:Fakultät für Chemie und Pharmazie / Institut für Funktionsmaterialien und Biofabrikation
Sprache der Veröffentlichung:Englisch
Titel des übergeordneten Werkes / der Zeitschrift (Englisch):Data in Brief
Erscheinungsjahr:2019
Band / Jahrgang:22
Seitenangabe:16-29
Originalveröffentlichung / Quelle:Data in Brief 22 (2019) 16-29. DOI: 10.1016/j.dib.2018.11.121
DOI:https://doi.org/10.1016/j.dib.2018.11.121
Allgemeine fachliche Zuordnung (DDC-Klassifikation):5 Naturwissenschaften und Mathematik / 54 Chemie / 540 Chemie und zugeordnete Wissenschaften
Freie Schlagwort(e):PALS; positron; positron annihilation lifetime spectroscopy
Datum der Freischaltung:12.04.2019
Sammlungen:Open-Access-Publikationsfonds / Förderzeitraum 2018
Lizenz (Deutsch):License LogoCC BY: Creative-Commons-Lizenz: Namensnennung 4.0 International