Refine
Is part of the Bibliography
- yes (244)
Year of publication
Document Type
- Journal article (129)
- Doctoral Thesis (113)
- Other (1)
- Preprint (1)
Keywords
- MRI (22)
- NMR-Tomographie (19)
- MRT (16)
- magnetic resonance imaging (13)
- Kernspintomografie (8)
- Herzinfarkt (7)
- Computertomographie (6)
- Quantifizierung (6)
- mri (6)
- Bildgebendes Verfahren (5)
Institute
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (244) (remove)
Sonstige beteiligte Institutionen
- Cheng Lab, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA (1)
- Datenintegrationszentrum Würzburg (DIZ) (1)
- Interdisziplinäre Biomaterial- und Datenbank Würzburg (ibdw) (1)
- Würzburg Fabry Center for Interdisciplinary Therapy (FAZIT), University of Würzburg, Würzburg, Germany (1)
Background and Objective
This study evaluates whether Computer Tomography is an effective procedure for preoperative staging of patients with Peritoneal Carcinomatosis.
Method
A sample of 37 patients was analyzed with contrast enhanced abdominal Computer Tomography, followed by surgical staging. All Computer Tomography scans were evaluated 3 times by 2 radiologists with one radiologist reviewing 2 times. The efficacy of Computer Tomography was evaluated using the Spearman correlation coefficient. Correlations were analyzed by abdominopelvic region to assess results of the Peritoneal Carcinomatosis Index (PCI) aggregating the 13 regions. Surgical findings were compared to radiological findings.
Results
Results indicate high correlations between the surgical and radiological Peritoneal Carcinomatosis Indices. Analyses of the intra-class correlation between the first and second reading of one radiologist suggest high intra-observer reliability. Correlations by abdominopelvic region show higher values in the upper and middle regions and relatively lower values in the lower regions and the small bowel (correlation coefficients range between 0.418 and 0.726, p < 0.010; sensitivities range between 50% and 96%; and specificities range between 62% and 100%).
Conclusion
Computer Tomography represents an effective procedure in the preoperative staging of patients with PC. However, results by abdominopelvic region show lower correlation, therefore suggest lower efficacy. These results are supported by analyses of sensitivity and accuracy by lesion size. This suggests that Computer Tomography is an effective procedure for pre-operative staging but less for determining a tumor's accurate extent.
Durch den mehrfachen Führungswechsel in der Radiologischen Abteilung der Frauenklinik der Universität Würzburg seit 1995, ergab sich die Frage, ob die verantwortlichen Radiologen sich in der Mammographiebeurteilung unterscheiden. Ausgehend von 8033 Mammographien von asymptomatischen- und Patientinnen mit einem klinischen Befund, wurde die Sensitivität, Spezifität, die Biopsierate, die Tumorentdeckung- und Recallrate für die einzelnen Untersucher ermittelt. Die wesentlichen Ergebnisse dieser Arbeit sind: 1. Die Sensitivität liegt bei durchschnittlich 97,14%, die Spezifität 98,62%. Die Tumorentdeckungsrate liegt zwischen 6,59‰ und 8,99‰, die Biopsierate beträgt 1,34% und die Recallrate 3,79%. 2. Für alle Behandler liegen diese Werte innerhalb der vom American College of Radiology und den European Guidelines for Quality Assurance in Mammography Screening vorgegebenen Richtlinien. 3. Es gibt keine signifikanten Unterschiede in der Mammographiebefundung durch die verschiedenen Untersucher. 4. Durch die Einführung der standardisierten Klassifikation der Befunde wird in Zukunft eine Qualitätssicherung der Mammographieuntersuchungen und eine Kontrolle der Ergebnisse gewährleistet.
Magnetic Particle Imaging (MPI) ist ein innovatives tomographisches Bildgebungsverfahren, mit dem Tracerpartikel äußerst sensitiv und schnell mehrdimensional abgebildet werden können. Die Methode basiert auf der nichtlinearen Magnetisierungsantwort superparamagnetischer Eisenoxidnanopartikel (SPION) in einem Messpunkt, welcher ein Messvolumen rastert. In vorliegender Arbeit wurde das sog. Traveling Wave MPI (TWMPI) Verfahren eingesetzt, wodurch im Vergleich zu konventionellen MPI-Scannern ein größeres Field of View (FOV) und eine geringere Latenz bis zur Bildanzeige erreicht werden konnte. TWMPI weist einige für medizinische Zwecke vielversprechende Eigenschaften auf: Es liefert zwei- und dreidimensionale Bildrekonstruktionen in Echtzeit mit hoher zeitlicher und räumlicher Auflösung. Dabei ist die Bildgebung von Grund auf hintergrundfrei und erfordert keinerlei ionisierende Strahlung. Zudem ist die Technik äußerst sensitiv und kann SPION-Tracer noch in mikromolaren Konzentrationen detektieren.
Ziel dieser Arbeit war es daher zu untersuchen, inwiefern es mittels TWMPI möglich ist, künstliche Stenosen im Gefäßmodell visuell in Echtzeit darzustellen und quantitativ zu beurteilen sowie überdies eine perkutane transluminale Angioplastie (PTA) im Gefäßmodell unter TWMPI-Echtzeit-Bildgebung durchzuführen.
Alle Experimente wurden in einem speziell angefertigten TWMPI-Scanner durchgeführt (JMU Würzburg, Experimentelle Physik V (Biophysik), FOV: 65 x 29 x 29 mm³, Auflösung: ca. 1.5 - 2 mm). Die Lumen-Darstellungen erfolgten mittels des SPION-Tracers Ferucarbotran in einer Verdünnung von 1 : 50 (entspr. 10 mmol [Fe]/l). Das PTA-Instrumentarium wurde mit eigens hergestelltem ferucarbotranhaltigem Lack (100 mmol [Fe]/l) markiert. Für die verschiedenen Teilexperimente wurden den jeweiligen speziellen Anforderungen entsprechend mehrere Gefäßmodelle handgefertigt.
Für die visuelle Stenosequantifizierung wurden fünf starre Stenosephantome unterschiedlicher Stenosierung (0%, 25%, 50%, 75%, 100%) aus Polyoxymethylen hergestellt (l: 40 mm, ID: 8 mm). Die Gefäßmodelle wurden mehrfach zentral im FOV platziert und das stenosierte Lumen mittels sog. Slice-Scanning Modus (SSM, Einzelaufnahme inkl. 10 Mittelungen: 200 ms, Bildfrequenz: 5 Bilder pro Sekunde, Latenz: ca. 100 ms) als zweidimensionale Quasi-Projektionen abgebildet. Diese Aufnahmen (n = 80, 16 je Phantom) wurden mit einer einheitlichen Grauskalierung versehen und anschließend entsprechend den NASCET-Kriterien visuell ausgewertet.
Alle achtzig Aufnahmen waren unabhängig vom Stenosegrad aufgrund einheitlicher Fensterung sowie konstanter Scannerparameter untereinander gut vergleichbar. Niedriggradige Stenosen konnten insgesamt genauer abgebildet werden als höhergradige, was sich neben der subjektiven Bildqualität auch in geringeren Standardabweichungen zeigte (0%: 3.70 % ± 2.71, 25%: 18.64 % ± 1.84, 50%: 52.82 % ± 3.66, 75%: 77.84 % ± 14.77, 100%: 100 % ± 0). Mit zunehmendem Stenosegrad kam es vermehrt zu geometrischen Verzerrungen im Zentrum, sodass bei den 75%-Stenosen eine breitere Streuung der Messwerte mit einer höheren Standardabweichung von 14.77% einherging. Leichte, randständige Artefakte konnten bei allen Datensätzen beobachtet werden.
Für die PTA wurden drei interaktive Gefäßmodelle aus Polyvinylchlorid (l: 100 mm, ID: 8 mm) mit zu- und abführendem Schlauchsystem entwickelt, welche mittels Kabelband von außen hochgradig eingeengt werden konnten. Analog zu einer konventionellen PTA mittels röntgenbasierter digitaler Subtraktionsangiographie (DSA), wurden alle erforderlichen Arbeitsschritte (Gefäßdarstellung, Drahtpassage, Ballonplatzierung, Angioplastie, Erfolgskontrolle) unter (TW)MPI-Echtzeit-Bildgebung (Framerate: 2 - 4 FPS, Latenz: ca. 100 ms) abgebildet bzw. durchgeführt.
Im Rahmen der PTA war eine Echtzeit-Visualisierung der Stenose im Gefäßmodell durch Tracer-Bolusgabe sowie die Führung des markierten Instrumentariums zum Zielort möglich. Die Markierung der Instrumente hielt der Beanspruchung während der Prozedur stand und ermöglichte eine genaue Platzierung des Ballonkatheters. Die Stenose konnte mittels Angioplastie-Ballons unter Echtzeit-Darstellung gesprengt werden und der Interventionserfolg im Anschluss durch erneute Visualisierung des Lumens validiert werden.
Insgesamt zeigt sich MPI somit als adäquate Bildgebungstechnik für die beiden in der Fragestellung bzw. Zielsetzung definierten experimentellen Anwendungen. Stenosen im Gefäßmodell konnten erfolgreich in Echtzeit visualisiert und bildmorphologisch nach NASCET-Kriterien quantifiziert werden. Ebenso war eine PTA im Gefäßmodell unter TWMPI-Echtzeit-Bildgebung machbar. Diese Ergebnisse unterstreichen das grundlegende Potenzial von MPI für medizinische Zwecke. Um zu den bereits etablierten Bildgebungsmethoden aufzuschließen, ist jedoch weitere Forschung im Bereich der Scanner-Hard- und -Software sowie bezüglich SPION-Tracern nötig.
Purpose
The reliable detection of tumor-infiltrated axillary lymph nodes for breast cancer [BC] patients plays a decisive role in further therapy. We aimed to find out whether cross-sectional imaging techniques could improve sensitivity for pretherapeutic axillary staging in nodal-positive BC patients compared to conventional imaging such as mammography and sonography.
Methods
Data for breast cancer patients with tumor-infiltrated axillary lymph nodes having received surgery between 2014 and 2020 were included in this study.
All examinations (sonography, mammography, computed tomography [CT] and magnetic resonance imaging [MRI]) were interpreted by board-certified specialists in radiology. The sensitivity of different imaging modalities was calculated, and binary logistic regression analyses were performed to detect variables influencing the detection of positive lymph nodes.
Results
All included 382 breast cancer patients had received conventional imaging, while 52.61% of the patients had received cross-sectional imaging.
The sensitivity of the combination of all imaging modalities was 68.89%. The combination of MRI and CT showed 63.83% and the combination of sonography and mammography showed 36.11% sensitivity.
Conclusion
We could demonstrate that cross-sectional imaging can improve the sensitivity of the detection of tumor-infiltrated axillary lymph nodes in breast cancer patients. Only the safe detection of these lymph nodes at the time of diagnosis enables the evaluation of the response to neoadjuvant therapy, thereby allowing access to prognosis and improving new post-neoadjuvant therapies.
The occurrence of different subtypes of endogenous Cushing’s syndrome (CS) in single individuals is extremely rare. We here present the case of a female patient who was successfully cured from adrenal CS 4 years before being diagnosed with Cushing’s disease (CD). The patient was diagnosed at the age of 50 with ACTH-independent CS and a left-sided adrenal adenoma, in January 2015. After adrenalectomy and histopathological confirmation of a cortisol-producing adrenocortical adenoma, biochemical hypercortisolism and clinical symptoms significantly improved. However, starting from 2018, the patient again developed signs and symptoms of recurrent CS. Subsequent biochemical and radiological workup suggested the presence of ACTH-dependent CS along with a pituitary microadenoma. The patient underwent successful transsphenoidal adenomectomy, and both postoperative adrenal insufficiency and histopathological workup confirmed the diagnosis of CD. Exome sequencing excluded a causative germline mutation but showed somatic mutations of the β-catenin protein gene (CTNNB1) in the adrenal adenoma, and of both the ubiquitin specific peptidase 8 (USP8) and the glucocorticoid receptor (NR3C1) genes in the pituitary adenoma. In conclusion, our case illustrates that both ACTH-independent and ACTH-dependent CS may develop in a single individual even without evidence for a common genetic background.
Introduction
In spinal surgery, precise instrumentation is essential. This study aims to evaluate the accuracy of navigated, O-arm-controlled screw positioning in thoracic and lumbar spine instabilities.
Materials and methods
Posterior instrumentation procedures between 2010 and 2015 were retrospectively analyzed. Pedicle screws were placed using 3D rotational fluoroscopy and neuronavigation. Accuracy of screw placement was assessed using a 6-grade scoring system. In addition, screw length was analyzed in relation to the vertebral body diameter. Intra- and postoperative revision rates were recorded.
Results
Thoracic and lumbar spine surgery was performed in 285 patients. Of 1704 pedicle screws, 1621 (95.1%) showed excellent positioning in 3D rotational fluoroscopy imaging. The lateral rim of either pedicle or vertebral body was protruded in 25 (1.5%) and 28 screws (1.6%), while the midline of the vertebral body was crossed in 8 screws (0.5%). Furthermore, 11 screws each (0.6%) fulfilled the criteria of full lateral and medial displacement. The median relative screw length was 92.6%. Intraoperative revision resulted in excellent positioning in 58 of 71 screws. Follow-up surgery due to missed primary malposition had to be performed for two screws in the same patient. Postsurgical symptom relief was reported in 82.1% of patients, whereas neurological deterioration occurred in 8.9% of cases with neurological follow-up.
Conclusions
Combination of neuronavigation and 3D rotational fluoroscopy control ensures excellent accuracy in pedicle screw positioning. As misplaced screws can be detected reliably and revised intraoperatively, repeated surgery for screw malposition is rarely required.
Durch die Anlage einer perkutanen transhepatischen Cholangiodrainage (PTCD), im Rahmen benigner und maligner biliärer Obstruktionen, wird eine Kommunikation zwischen Hautoberfläche, Peritoneum und dem biliären System geschaffen. Insbesondere nach Entfernung der PTCD besteht das Risiko einer Galleleckage, einer Blutung, einer biliokutanen Fistel oder einer lokalen Peritonitis, mit durchaus schwerwiegenden Konsequenzen. Die Embolisation dieses Stichkanals nach Entfernung der Drainage mittels Gelatineschwamm (Gelfoam) stellt eine einfache und effektive Lösung dar diese Komplikationen zu reduzieren und zu verhindern. Ziel dieser Studie war es, die Effektivität der Stichkanalembolisation mittels Gelatineschwamm nach PTCD retrospektiv zu evaluieren.
Die Arbeit zeigt bei verschiedenen Patientengruppen, dass mit Hilfe der quantitativen 31P-MR-Spektroskopie der Energiemetabolismus des Myokards beurteilt werden kann. Mit der gewählten Methode SLOOP ist nun auch eine Bestimmung der absoluten Konzentration der energiereichen Phosphate PCr und ATP möglich; im Gegensatz dazu wurde bisher nur das Verhältnis von PCr/ATP bestimmt. Die Beobachtungen bei Patienten mit Aortenklappenfehlern zeigten vor und nach Aortenklappenersatz Veränderungen, ebenso wurden bei Patienten mit Dilatativer Kardiomyopathie nach Einsatz von ß-Blockern bzw. nach Beginn regelmäßiger körperlicher Aktivität Verbessserungen des Energiestoffwechsels beobachet.
Zusammenfassend lässt sich sagen, dass auch in dieser Studie die MRT bewiesen hat, dass sie eine Diagnostik ist, die aufgrund ihrer vielen Vorteile (röntgenstrahlenfrei, schmerzfrei, hochauflösende Diagnostik) der konventionellen Mammographie überlegen ist. Im Vergleich mit anderen diagnostischen Möglichkeiten, weist die MRT die höchsten Sensitivitäten auf. Viele falsch positive Befunde könnten so vermieden werden und unnötige Biopsien umgangen werden.
Die MRT zeigte in dieser Studie eine Sensitivität von 78%, für reine DCIS 76%.
Die in der präoperativen MR-Diagnostik gemessenen Größen korrelierten statistisch signifikant mit der histologisch bestimmten Größe für alle Gruppen (reines DCIS, begleitendes DCIS, mikroinvasives DCIS) zusammen genommen (c=0,378; p<0,01) sowie für reine DCIS (c=0,403; p<0,05). Desweiteren korrelierten die Größen statistisch signifikant für high-grade DCIS (c=0,493; p<0,05) und für Nekrosen positive DCIS (c=0,556; p<0,01). Hier ließen sich die Tumorgrößen verlässlich vorhersagen.
In der Auswertung der Signalintensitäts-Zeit-Kurven zeigten sich signifikante Unterschiede zwischen den Gruppen hinsichtlich der initialen (p<0,05) und postinitialen Phase (p<0,01). So lässt sich anhand der KM-Kinetik eine Aussage über die Malignität treffen. Ein reines DCIS zeigte typischerweise eine initiale Phase mit einem KM-Anstieg von 50-100% oder >100%, gefolgt von einer Plateau-Phase. Ein invasives Carcinom begleitendes DCIS zeichnete sich durch einen raschen Anstieg >100% gefolgt von einem „wash-out“ und einem inhomogenen, unbegrenzten Anreicherungsverhalten aus. Mikrovinvasive DCIS zeigten ähnlich den reinen DCIS einen initialen Anstieg von 50-100% sowie eine folgende Plateau-Phase.
Keinen statistisch signifikanten Einfluss hatte die präoperative Größenbestimmung auf das operativen Verfahren (BET vs. Ablatio). Trotz der präoperativen MRT waren zu 29,6 % Nachresektionen - davon ca. die Hälfte (14,1%) als sekundäre Ablatio - nötig.
Mit der MRT ließen sich grundsätzlich verlässliche präoperative Vorhersagen hinsichtlich Größe und Malignität treffen. Signalintensitäts-Zeit-Kurven und höhere Feldstärken, wie die 3T-MRT, könnten sehr hilfreich sein und die Sensitivität und Spezifität verbessern. Warum trotz allem noch so viele Nachresektionen nötig sind, gilt es in folgenden Studien zu untersuchen.