Refine
Is part of the Bibliography
- yes (875) (remove)
Year of publication
- 2015 (875) (remove)
Document Type
- Journal article (438)
- Doctoral Thesis (343)
- Complete part of issue (50)
- Book article / Book chapter (12)
- Review (7)
- Conference Proceeding (6)
- Working Paper (6)
- Book (4)
- Report (3)
- Jahresbericht (2)
- Master Thesis (1)
- Other (1)
- Preprint (1)
- Study Thesis (term paper) (1)
Keywords
- Universität (47)
- University (46)
- Wuerzburg (46)
- Wurzburg (46)
- Würzburg (46)
- expression (19)
- ATLAS detector (18)
- proton-proton collision (13)
- cancer (11)
- in vitro (11)
Institute
- Theodor-Boveri-Institut für Biowissenschaften (98)
- Physikalisches Institut (87)
- Universität - Fakultätsübergreifend (46)
- Graduate School of Life Sciences (45)
- Medizinische Klinik und Poliklinik I (34)
- Institut für Psychologie (32)
- Medizinische Klinik und Poliklinik II (32)
- Neurologische Klinik und Poliklinik (29)
- Klinik und Poliklinik für Psychiatrie, Psychosomatik und Psychotherapie (26)
- Institut für Pharmazie und Lebensmittelchemie (23)
Sonstige beteiligte Institutionen
- ATLAS Collaboration (1)
- Adam Opel AG (1)
- Bayerische Museumsakademie (1)
- Bayerisches Zentrum für Angewandte Energieforschung e.V. (1)
- Bezirk Unterfranken (1)
- Brown University (1)
- CERN (1)
- Center for Nanosystems Chemistry (CNC), Universität Würzburg, Am Hubland, 97074 Würzburg, Germany (1)
- Deutscher Akademischer Austauschdienst (DAAD) (1)
- Deutsches Zentrum für Luft- und Raumfahrt (DLR), Institut für Raumfahrtsysteme (1)
ResearcherID
- B-1911-2015 (1)
- C-2593-2016 (1)
- D-1221-2009 (1)
- N-2030-2015 (1)
- N-3741-2015 (1)
Im Rahmen dieser Arbeit sollten die Möglichkeiten der MR Tomographie erkundet werden bakterielle Infektionen im Zeitverlauf darzustellen. Genauer gesagt sollte das Potential der MR Tomographie anhand eines durch eine Infektion induzierten lokalisierten Abszesses unter Verwendung dreier unterschiedlicher MRT Methoden untersucht werden: Mittels nativem \(T_2\) Kontrast; der Verwendung von superparamagnetischen Eisenoxid Partieln (USPIO) als \(T_2^*\) Kontrastmittel; und dem Einsatz von Perfluorkarbonen (PFC) als \(^{19}F\) MRT Marker (siehe Kapitel 3).
Wie erwartet führte die durch die Infektion hervorgerufene Entzündung zu veränderten \(T_2\)-Zeiten, welche auf \(T_2\)-gewichteten MR Bildern eine Lokalisierung des Abszessbereiches erlauben. Jedoch eigneten sich diese Daten aufgrund der graduellen Änderung der \(T_2\)-Zeiten nicht, um eine klare Grenze zwischen Abszess und umliegendem Gewebe zu ziehen.
Superparamagnetische Eisenoxidpartikel andererseit haben als MRT Kontrastmittel bereits in den letzten Jahren ihre Fähigkeit unter Beweis gestellt Entzündungen [53, 58, 64] darzustellen. Die Anreicherung dieser Partikel am Rande des Abszesses [53], wie sie auch in unseren MR Daten zu beobachten war, erlaubte eine relativ scharfe Abgrenzung gegenüber dem umgebenden Gewebe in der chronischen Phase der Infektion (Tag 9 p.i.). Hingegen genügte die nur sehr spärlichen Anreicherung von USPIO Partikeln in der akuten Phase der Infektion (Tag 3 p.i.) nicht für eine entsprechende Abgrenzung [58].
Aufgrund der sehr geringen biologischen Häufigkeit und den sehr kurzen Relaxationszeiten von endogenem Fluor eignen sich Perfluorkarbone als Markersubstanz in der MR Tomographie von biologischen Systemen. Insbesondere da PFC Emulsionen durch phagozytierende Zellen aufgenommen werden und im Bereich von Entzündungen akkumulieren [30, 59]. In dieser Arbeit konnte anhand der erhaltenen MRT Daten eine Akkumulation von Perfluorkarbonen nicht nur in der chronischen Phase, sondern auch in der akuten Phase nachgewiesen werden. Diese Daten erlauben somit zu allen untersuchten Zeitpunkten eine Abgrenzung zwischen Infektion und umliegenden Gewebe.
Aufgrund der besagten Vorteile wurden die Perfluorkarbone gewählt, um die Möglichkeiten der MR Tomographie zu testen, quantitative Informationen über die schwere der Infektion zu liefern. Als Referenz für die Bakterienbelastung wurden die Biolumineszenzbildgebung (BLI) [49, 50] und die Standardmethode zur Bestimmung der Bakterienbelastung cfu (koloniebildenden Einheiten) herangezogen. Eine Gegenüberstellung der zeitlichen Verläufe der durch die Biolumineszenzbildgebung und durch die cfu erhaltenen Daten liefert eine qualitative Übereinstimmung mit den durch die 19F MR Tomographie erhaltenen Daten. Dies trifft hierbei sowohl auf die über den gesamten Infektionsbereich hinweg summierten Signalamplituden, als auch auf das Volumen zu, in dem Fluor am Ort der Infektion akkumuliert wurde. Im Gegensatz zur Methode der cfu Bestimmung sind die MR Tomographie und die Biolumineszenzbildgebung nicht invasiv und erlauben die Verfolgung des Infektionsverlaufes an einem einzelnen Individuum. Hierzu benötigt, im Gegensatz zur MR Tomographie, die Methode der Biolumineszenzbildgebung jedoch einen speziellen Pathogenstamm. Darüber hinaus ist hervorzuheben, dass die MR Tomographie zudem die Möglichkeit bietet auch morphologische Informationen über den Infektionsbereich und seine Umgebung zu akquirieren.
Gerade weil jede dieser Methoden die mit der Infektion einhergehenden Prozesse aus einer leicht anderen Blickrichtung betrachtet, erscheint es sinnvoll diese etablierte Untersuchungsplattform bestehend aus MRT, BLI und cfu über die in dieser Arbeit bearbeitete Fragestellung hinaus näher zu untersuchen. Insbesondere der Aspekt inwieweit die drei Methoden sich gegenseitig ergänzen, könnte einen tieferen Einblick in die Wechselwirkung zwischen Pathogen und Wirt erlauben.
Auch wenn für die betrachtete Fragestellung bereits der hierdurchgeführte semiquanitative Ansatz zur Bestimmung der relativen Fluormengen am Ort der Infektion ausreichte, so ist doch im Allgemeinen wünschenswert probenbezogen die Sensitivität der Spule und damit die Güte der Spulenabstimmung zu bestimmen. Hierzu ist jedoch die Aufnahme von \(B_1\)-Karten unabdingbar und wird entsprechend im Kapitel 4 \(Bloch-Siegert B_1^+-Mapping\) näher addressiert. Der Schwerpunkt liegt hierbei, wie der Kapitelname bereits andeutet, auf der Bloch-Siegert Methode, die insbesondere in der präsentierten Implementierung in einer Turbo/ Multi Spin Echo Sequenz eine effiziente Nutzung der relativ langen \(T_\)2-Zeiten der Perfluorkarbone erlaubt. Da zudem die Bloch-Siegert-Methode eine rein phasenbasierte Methode ist, kann neben der aus den Daten erzeugten \(B_1\)-Karte zugleich ein unverfälschtes Magnitudenbild generiert werden, wodurch eine sehr effiziente Nutzung der vorhandenen Messzeit ermöglicht wird. Diese Eigenschaft ist insbesondere für \(^{19}F\) Bildgebung von besonderem Interesse, da hier für jede Messung, aufgrund der üblicherweise relativ geringen Konzentration an Fluoratomen, lange Messzeiten benötigt werden.
Zusammenfassend konnte anhand des untersuchten Tiermodells sowohl die Fähigkeit der MR Tomographie nachgewiesen werden Infektionen im Zeitverlauf darzustellen, als auch die Fähigkeit der MR Tomographie quantitative Informationen über den Verlauf der Infektion zu liefern. Desweiteren konnte eine Möglichkeit aufgezeigt werden, welche das Potential hat in vertretbarem Zeitrahmen auch in vivo B1+-Karten auf dem Fluorkanal zu erstellen und so einen zentralen Unsicherheitsfaktor, für Relaxometry und absolute Quantifizierung von \(^{19}F\) Daten in vivo, zu beseitigen.
Multiple myeloma (MM) remains an essentially incurable hematologic malignancy. However, new treatment modalities and novel drugs have been introduced and thus additional tools for therapy monitoring are increasingly needed. Therefore, we evaluated the radiotracers \(^{11}\)C-Methionine (paraprotein-biosynthesis) and \(^{18}\)F-FDG (glucose-utilization) for monitoring response to anti-myeloma-therapy and outcome prediction. Influence of proteasome-inhibition on radiotracer-uptake of different MM cell-lines and patient-derived CD138\(^{+}\) plasma cells was analyzed and related to tumor-biology. Mice xenotransplanted with MM. 1S tumors underwent MET- and FDG-\(\mu\)PET. Tumor-to-background ratios before and after 24 h, 8 and 15 days treatment with bortezomib were correlated to survival. Treatment reduced both MET and FDG uptake; changes in tracer-retention correlated with a switch from high to low CD138-expression. In xenotransplanted mice, MET-uptake significantly decreased by 30-79% as early as 24 h after bortezomib injection. No significant differences were detected thus early with FDG. This finding was confirmed in patient-derived MM cells. Importantly, early reduction of MET-but not FDG-uptake correlated with improved survival and reduced tumor burden in mice. Our results suggest that MET is superior to FDG in very early assessment of response to anti-myeloma-therapy. Early changes in MET-uptake have predictive potential regarding response and survival. MET-PET holds promise to individualize therapies in MM in future.
3d-Übergangsmetallphthalocyanin-Moleküle auf Metalloberflächen: Der Einfluss der d-Orbitalbesetzung
(2015)
Im Rahmen dieser Dissertation wird die Untersuchung von 3d-Übergangsmetallphthalocyanin- Molekülen (ÜMPc) – quadratisch-planaren organischen Molekülen, welche im Zentrum ein 3d-Übergangsmetallion besitzen – auf metallischen Oberflächen vorgestellt. Der Fokus dieser Arbeit liegt dabei auf dem Einfluss der d-Orbitalbesetzung auf die magnetischen, elektronischen und strukturellen Eigenschaften der adsorbierten Moleküle, die mit Hilfe der Rastertunnelmikroskopie und -spektroskopie charakterisiert wurden. Die gewonnen Ergebnisse werden zum Teil mit theoretischen Berechnungen analysiert und interpretiert.
Die erste Hälfte der experimentellen Auswertung behandelt die Untersuchung dieser Moleküle auf Ag(001) in Hinblick auf die Existenz einer magnetischen Wechselwirkung, bei der ein unkompensiertes magnetisches Moment des Moleküls durch die Substratelektronen abgeschirmt wird. Dieser Effekt wird als Kondo-Abschirmung bezeichnet und erzeugt in der Zustandsdichte des Moleküls eine Resonanz am Fermi-Niveau. Die Messungen zeigen, dass diese Resonanz ausschließlich am Zentralion von MnPc vorgefunden wird, wohingegen sie bei allen anderen 3d-Übergangsmetallphthalocyanin-Molekülen, die eine höhere d-Orbitalbesetzung besitzen, nicht vorhanden ist. Anhand theoretischer Berechnungen kann die Ursache für dieses Verhalten darauf zurückgeführt werden, dass von allen d-Orbitalen einzig das dz2-Orbital mit dem Substrat geeignet hybridisiert, um eine Kondo-Abschirmung zu erzeugen. Da ausschließlich MnPc einen unkompensierten Spin in diesem Orbital besitzt, kann die An- bzw. Abwesenheit
des Kondo-Effekts auf die unterschiedliche Besetzung des dz2-Orbitals zurückgeführt werden. Neben der eben erwähnten Kondo-Resonanz ist bei MnPc ein weiteres Merkmal am Fermi- Niveau überlagert. Durch die Analyse der räumlichen Verteilung, den Vergleich mit anderen Molekülen und der Manipulation des MnPc-Moleküls kann gezeigt werden, dass es sich bei diesem Merkmal um einen d-Orbitalzustand handelt. Die Manipulation des Moleküls durch gezieltes Entfernen von Wasserstoffatomen ermöglicht darüber hinaus die Stärke der Kondo-Abschirmung zu beeinflussen.
In der zweiten Hälfte der experimentellen Auswertung werden Moleküle auf bismutinduzierten Oberflächenlegierungen der Edelmetalle Cu(111) und Ag(111) untersucht. Diese Legierungen zeichnen sich durch einen ausgeprägten Rashba-Effekt aus, der durch eine Aufspaltung der Parabeldispersion und Aufhebung der Spin-Entartung im zweidimensionalen Elektronengas der Oberflächenlegierung charakterisiert ist. Das Wachstumsverhalten von CuPc und MnPc auf diesen Oberflächen zeigt ein sehr gegensätzliches Verhalten. Während bei MnPc die Substrat-Molekül-Wechselwirkung dominant ist, wodurch diese Moleküle immer einen festen Adsorptionsplatz auf der Oberfläche besitzen, ist diese Wechselwirkung bei CuPc schwach ausgeprägt. Aus diesem Grund wandern die CuPc-Moleküle zu den Stufenkanten und bilden Cluster. Das unterschiedliche Wachstumsverhalten der Moleküle lässt sich auf die partiell-gefüllten d-Orbitale von MnPc zurückführen, die aus der Molekülebene ragen, mit dem Substrat hybridisieren und damit das Molekül an das Substrat binden. Bei CuPc hingegen sind diese d-Orbitale gefüllt und die Hybridisierung kann nicht stattfinden.
Im letzten Abschnitt werden die elektronischen und magnetischen Eigenschaften von MnPc auf diesen Substraten behandelt, die einige Besonderheiten aufweisen. So bildet sich durch die Adsorption des Moleküls auf den Oberflächen eine Grenzschichtresonanz aus, die eine partielle Füllung erkennen lässt. Spektroskopiedaten, aufgenommen am Ort der Grenzschichtresonanz, weisen eine symmetrisch um das Fermi-Niveau aufgespaltene Resonanz auf. Die Intensität der unter- und oberhalb der Fermi-Energie befindlichen Resonanz zeigen dabei ein komplementäres Verhalten bzgl. der jeweiligen Lage auf der Grenzschichtresonanz: An den Orten, an denen die Resonanz unterhalb des Fermi-Niveaus ihre maximale Intensität besitzt, ist die Resonanz oberhalb des Fermi-Niveaus nicht vorhanden und umgekehrt. Diese experimentellen Beobachtungen werden mit einem Modellansatz erklärt, welcher die Wirkung eines effektiven Magnetfeldes und eine Spin-Filterung postuliert.
3D visualization of movements can amplify motor cortex activation during subsequent motor imagery
(2015)
A repetitive movement practice by motor imagery (MI) can influence motor cortical excitability in the electroencephalogram (EEG). This study investigated if a realistic visualization in 3D of upper and lower limb movements can amplify motor related potentials during subsequent MI. We hypothesized that a richer sensory visualization might be more effective during instrumental conditioning, resulting in a more pronounced event related desynchronization (ERD) of the upper alpha band (10–12 Hz) over the sensorimotor cortices thereby potentially improving MI based brain-computer interface (BCI) protocols for motor rehabilitation. The results show a strong increase of the characteristic patterns of ERD of the upper alpha band components for left and right limb MI present over the sensorimotor areas in both visualization conditions. Overall, significant differences were observed as a function of visualization modality (VM; 2D vs. 3D). The largest upper alpha band power decrease was obtained during MI after a 3-dimensional visualization. In total in 12 out of 20 tasks the end-user of the 3D visualization group showed an enhanced upper alpha ERD relative to 2D VM group, with statistical significance in nine tasks.With a realistic visualization of the limb movements, we tried to increase motor cortex activation during subsequent MI. The feedback and the feedback environment should be inherently motivating and relevant for the learner and should have an appeal of novelty, real-world relevance or aesthetic value (Ryan and Deci, 2000; Merrill, 2007). Realistic visual feedback, consistent with the participant’s MI, might be helpful for accomplishing successful MI and the use of such feedback may assist in making BCI a more natural interface for MI based BCI rehabilitation.