Refine
Has Fulltext
- yes (7)
Is part of the Bibliography
- yes (7)
Document Type
- Doctoral Thesis (4)
- Journal article (3)
Keywords
- total hip arthroplasty (7) (remove)
Purpose
The goal of our study was to conduct an online survey that highlights patterns of practice during total hip arthroplasty (THA).
Methods
The survey was conducted in June and August 2020. Three hundred thirteen members of the German Society for Endoprosthesis participated in the survey.
Results
The anterolateral approach is by far the most popular approach used for primary total hip arthroplasty, followed by the anterior approach during minimally invasive (55% for the anterolateral and 29% for the anterior) and regular surgery (52% for the anterolateral and 20% for the anterior). Two-thirds of the orthopaedic surgeons do not use drainages during THA. Moreover, 80% of the survey participants routinely apply tranexamic acid during surgery. Surgeons who perform minimally invasive surgery for THA use more frequently fast-track-concepts for post-operative rehabilitation. According to the interviewees, the application of fast-track-concepts leads to reduced periods of hospital stay after THA.
Conclusion
Our data demonstrate that patterns of practice during THA in Germany are in line with the evidence provided by current literature. This study can be seen as a stimulus to conduct similar surveys in other countries in order to promote minimally invasive surgery for THA.
Hintergrund: Die Entwicklung minimal-invasiver gewebeschonender Zugangswege in der Hüftendoprothetik ist im Allgemeinen mit einer schnelleren Rehabilitation, einer Verringerung der postoperativen Schmerzen und einem erhöhten Patientenkomfort verbunden. Das Ziel dieser Studie war es, einen anterioren minimal-invasiven mit einem transglutealen lateralen Zugangsweg für Hüftgelenksersatzoperationen in Bezug auf postoperatives Schmerzniveau, den Schmerzmittelgebrauch, die Länge des Krankenhausaufenthalts und die Zeit bis zum Erreichen eines definierten physiotherapeutischen Therapiezieles zu vergleichen.
Methoden: In dieser retrospektiven Kohortenstudie untersuchten wir 200 Patienten, die sich einer Hüftendoprothesenimplantation unterzogen. Gruppe I (n = 100) erhielt einen minimal-invasiven anterioren Hüftzugang (modifiziert nach Smith-Peterson), Gruppe II (n = 100) erhielt einen lateralen transglutealen Zugang (nach Bauer). Die Untersuchungsziele waren der Schmerz in Ruhe und während der Physiotherapie, der Schmerzmittelgebrauch, die Länge des stationären Aufenthaltes sowie die Zeitdauer bis zum Erreichen des physiotherapeutischen Therapiezieles.
Ergebnisse: Die Patienten der Gruppe I konsumierten weniger Schmerzmedikamente (19,6 ± 6,9 mg Piritramid gegenüber 23,6 ± 11,3 mg; p = 0,005) und hatten in der frühen postoperativen Phase weniger Schmerzen (Operationstag: VAS 1,3 ± 1 gegenüber 2,3 ± 1,3, p = 0,0001, erster postoperativer Tag: VAS 0,41 ± 0,8 vs. 0,66 ± 1,1, p = 0,036). Die Zeit bis zum Erreichen des definierten Therapiezieles (6,4 ± 2 Tage gegenüber 7,4 ± 2,1 Tagen; p = 0,001) und die Dauer des Krankenhausaufenthalts waren kürzer (10,2 ± 1,9 Tage gegenüber 13,4 ± 1,6 Tagen; p = 0,0001) für Gruppe I. Die Schmerzen während der Physiotherapie waren jedoch am dritten und sechsten bis neunten Tag nach der Operation im Vergleich zu Gruppe II höher (p = 0,001–0,013).
Schlussfolgerung: Die Implantation einer Hüftprothese über einen minimal-invasiven anterioren Zugang führt in der direkt postoperativen Phase zu einer Reduktion des Schmerzniveaus und des Schmerzmittelgebrauchs. Zusätzlich werden das Erreichen des physiotherapeutischen Therapiezieles und die Länge des stationären Aufenthaltes positiv beeinflusst. Den höheren Schmerzen während der Physiotherapie könnte durch eine Reduktion der erlaubten Gewichtsbelastung in der frühen postoperativen Phase entgegengewirkt werden.
Background:
The presented prospective randomized controlled single-centre study compares the clinical outcome up to 12 months after total hip arthroplasty using a minimally invasive single-incision direct anterior (DAA) and a direct transgluteal lateral approach.
Methods:
A total of 123 arthroplasties were evaluated utilizing the Harris Hip Score (HHS), the extra short musculoskeletal functional assessment questionnaire (XSFMA), the Short Form 36 (SF-36) health survey, a Stepwatch™ Activity Monitor (SAM), and a timed 25 m foot walk (T25-FW). Postoperative x-ray images after THA were reviewed to determine inclination and stem positioning.
Results:
At final follow-up, the XSFMA functional index scores were 10.3 (anterior) and 15.08 (lateral) while the bother index summed up to a score of 15.8 (anterior) and 21.66 (lateral) respectively, thus only differing significantly for the functional index (p = 0.040 and p = 0.056). The SF-36 physical component score (PCS) was 47.49 (anterior) and 42.91 (lateral) while the mental component score (MCS) summed up to 55.0 (anterior) and 56.23 (lateral) with a significant difference evident for the PCS (p = 0.017; p = 0.714). Patients undergoing THA through a DAA undertook a mean of 6402 cycles per day while those who had undergone THA through a transgluteal approach undertook a mean of 5340 cycles per day (p = 0.012). Furthermore, the obtained outcome for the T25-FW with 18.4 s (anterior) and 19.75 s (lateral) and the maximum walking distance (5932 m and 5125 m) differed significantly (p = 0.046 and p = 0.045). The average HHS showed no significant difference equaling 92.4 points in the anterior group and 91.43 in the lateral group (p = 0.477). The radiographic analysis revealed an average cup inclination of 38.6° (anterior) and 40.28° (lateral) without signs of migration.
Conclusion:
In summary, our outcomes show that after 1 year THA through the direct anterior approach results in a higher patient activity compared to THA utilizing a transgluteal lateral approach while no differences regarding hip function are evident.
Background:
To prevent bone loss in hip arthroplasty, several short stem systems have been developed, including the Mayo conservative hip system. While there is a plethora of data confirming inherent advantages of these systems, only little is known about potential complications, especially when surgeons start to use these systems.
Methods:
In this study, we present a retrospective analysis of the patients’ outcome, complications and the complication management of the first 41 Mayo conservative hips performed in 37 patients. For this reason, functional scores, radiographic analyses, peri- and postoperative complications were assessed at an average follow-up of 35 months.
Results:
The overall HHS improved from 61.2 pre-operatively to 85.6 post-operatively. The German Extra Short Musculoskeletal Function Assessment Questionnaire (XSFMA-D) improved from 30.3 pre-operatively to 12.2 post-operatively. The most common complication was an intraoperative non-displaced fracture of the proximal femur observed in 5 cases (12.1%). Diabetes, higher BMI and older ages were shown to be risk factors for these intra-operative periprosthetic fractures (p < 0.01). Radiographic analysis revealed a good offset reconstruction in all cases.
Conclusion:
In our series, a high complication rate with 12.1% of non-displaced proximal femoral fractures was observed using the Mayo conservative hip. This may be attributed to the flat learning curve of the system or the inherent patient characteristics of the presented cohort."
Das Hauptproblem des künstlichen Gelenkersatzes stellt die aseptische Prothesenlockerung dar. Hierbei handelt es sich um ein multifaktoriell bedingtes Geschehen, das auf ein gestörtes Zusammenspiel von biologischen und mechanischen Faktoren zurückzuführen ist. Im Rahmen dieser Arbeit wurden fünf modifizierte, bioaktivierte Knochenzemente bezüglich ihrer Verbundfestigkeit mit Edelstahl und ihrer Hydrolysestabilität untersucht. Ein gemeinsamer Bestandteil aller fünf Modifikationen stellt Hydroxyethylmethacrylat-Phosphat dar. Die Verbundfestigkeit der Zemente wurde anhand unterschiedlicher Anwendungs- bzw Metallvorbehandlungsvoraussetzungen im axialen Zugtest vor und nach künstlicher Alterung ermittelt. Unabhängig von der Vorbehandlung bzw. Anwendungsmodifikation zeigte der ausschließlich mit HEMA-P modifizierte Zement und der Referenzzement annähernd gleiche Zugfestigkeitswerte während die Zementmodifikation mit HEMA-P und zusätzlich Natriumcarbonat und Calciumchlorid deutlich niedrigere Zugfestigkeiten erreichte. Diese Modifikation konnte zudem, bis auf die Testreihe mit erfolgter Silikatisierung und silanisiertem Monomer, dem künstlichen Alterungsprozess nicht standhalten, was die Hydrolysestabilität dieser Modifikation in Frage stellt. Die höchsten Zugfestigkeitswerte nach dem Alterungsprozess konnten, unabhängig von der Zementmodifikation, bei der Testreihe mit erfolgter Silikatisierung und einem mit Silanhaftvermittler angereicherten Monomer festgestellt werden. Die Zemente wurden auf ihre Druckfestigkeit und im vereinfachten dynamischen Hüftprüfstandversuch im flüssigen Milieu getestet. Die Tatsache, dass sich bei allen Zementmodifikationen relativ wenig Spalten am Zement-Metall-Interface nachweisen ließen, spricht für eine gesteigerte Hydrolysebeständigkeit unter dynamischer Belastung. Die ermittelten Druckfestigkeiten liegen im Bereich von 83,85 MPa für PM 10, 89,66 MPa für PM 11 und 82 MPa für SPM 10 was den Anforderungen an Knochenzemente gerecht wird. Diese sollten gemäß ISO 5833 eine Druckfestigkeit von über 70 MPa aufweisen. Um eine detaillierte Aussage über die mechanischen Eigenschaften dieser Zementmodifikationen treffen zu können bedarf es weiterer Materialprüfungen
Die Studie untersucht Aktivitätsverlauf, Funktionsstatus und Lebensqualität nach minimal-invasivem anteriorem Zugang bei Hüfttotalendoprothesen (präoperativ bis sechs Wochen postoperativ) mit Hilfe der Fragebögen PHQ-D, XSMFA-D, SF-36, HHS, Täglicher Würzburger Aktivitätsfragebogen, Arzt- u. Patientenbogen Hüfte.
In den letzten Jahrzehnten ist die Anzahl der degenerativen Gelenkerkrankungen wie die Coxarthrose und somit die Zahl der zu implantierenden Hüfttotalendoprothesen stark gestiegen. Ziel der vorliegenden Arbeit ist es, langfristige Ergebnisse zementierter Titanschaftprothesen in Bezug auf aseptische Lockerungen zu ermitteln. Von den in der Orthopädischen Universitätsklinik Würzburg implantierten Hüfttotalendoprothesen von Januar 1990 bis März 1992 konnten nach durchschnittlich 9 Jahren 110 Hüfttotalendoprothesen klinisch und radiologisch nachuntersucht werden. Zum Zeitpunkt der Kontrolluntersuchung hatten die Patienten ein mittleres Alter von 76 Jahren. In allen Fällen wurden Müller-Geradschaftprothesen mit einer Ti-6A1-7Nb-Legierung in matter Oberfläche, Biolox®-Keramik-Köpfe sowie Knochenzement Palacos-® verwendet. Es wurde bei 4 Hüft-TEPs wegen aseptischer Lockerung ein Prothesenwechsel durchgeführt. Das nachuntersuchte Patientengut wurde in 3 Gruppen eingeteilt. Gruppe A rekrutierte sich aus denjenigen Patienten, bei denen keine radiologischen Lockerungszeichen erkennbar waren. Die Patienten mit mehr als einem Lysesaum jedoch mit festem Sitz der Schaftprothese im Vergleich zu den postoperativen Röntgenbildern wurden der Gruppe B zugeordnet. Letztendlich bildeten die Patienten mit ausgeprägten Lockerungszeichen bzw. vollständig gelockerte Prothesen die Gruppe C. Der Harris-Hip-Score der Gruppe A mit 85 ( 13) Punkten und der Gruppe B mit 86 ( 14) Punkten zeigte gute Ergebnisse. Der Harris-Score lag in der Gruppe C bei 76 (± 5) Punkten und erreichte somit ein mäßiges Ergebnis. Im Vergleich zu den Gruppen A und B erwies sich diese Punktezahl als signifikant schlechter. Die Patienten mit ausgeprägten Lockerungszeichen waren signifikant jünger (im Mittel 6 Jahre) als die der Gruppe ohne Lockerungssäume. Ebenfalls fanden wir einen signifikanten Unterschied im Bezug auf das Körpergewicht, Körpergewicht im Verhältnis zu zementierter Schaftoberfläche und Harris-Score (88 vs. 75 kg; 1,5 vs. 1,0 kg/cm; 76 vs. 85). Für Geschlecht, Schaftgröße, Schaftart, Aktivität, heterotope Ossifikationen und Body-Maß-Index traf dies nicht zu. Unter Berücksichtigung der erhobenen Daten (Harris-Hüft-Score und Quotient des Körpergewichts zur zementierten Schaftoberfläche) sollte eine möglichst große Prothese implantiert werden, um das Körpergewicht auf eine große Schaftoberfläche zu verteilen. Insgesamt hat sich die zementierte Müller-Geradschaftprothese aus Titanlegierung bewährt, so dass sie für die Behandlung von Nickelallergiker zu empfehlen ist.