Physikalisches Institut
Refine
Is part of the Bibliography
- yes (781)
Year of publication
Document Type
- Doctoral Thesis (409)
- Journal article (356)
- Conference Proceeding (4)
- Preprint (4)
- Master Thesis (3)
- Review (3)
- Habilitation (1)
- Other (1)
Keywords
- Molekularstrahlepitaxie (31)
- Topologischer Isolator (31)
- Quantenpunkt (30)
- Hadron-Hadron scattering (experiments) (29)
- Kernspintomografie (28)
- Parton Distributions (25)
- Photoelektronenspektroskopie (23)
- MRI (20)
- NMR-Tomographie (19)
- Organischer Halbleiter (19)
Institute
- Physikalisches Institut (781)
- Medizinische Klinik und Poliklinik I (15)
- Institut für Physikalische und Theoretische Chemie (9)
- Deutsches Zentrum für Herzinsuffizienz (DZHI) (6)
- Institut für diagnostische und interventionelle Neuroradiologie (ehem. Abteilung für Neuroradiologie) (6)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (6)
- Institut für Molekulare Infektionsbiologie (5)
- Institut für Organische Chemie (5)
- Institut für Theoretische Physik und Astrophysik (5)
- Rudolf-Virchow-Zentrum (5)
Sonstige beteiligte Institutionen
- Wilhelm-Conrad-Röntgen-Forschungszentrum für komplexe Materialsysteme (4)
- Universitätsklinikum Würzburg (3)
- Röntgen Center for Complex Material Systems (RCCM), Am Hubland, 97074 W¨urzburg, Germany (2)
- ATLAS Collaboration (1)
- Arizona State University, Tempe, Arizona, USA (1)
- Bavarian Center for Applied Energy Research (ZAE Bayern), 97074 Würzburg, Germany (1)
- Bavarian Center for Applied Energy Research e.V. (ZAE Bayern) (1)
- Bayerisches Zentrum für Angewandte Energieforschung e.V. (1)
- Biomedizinische NMR Forschungs GmbH am Max-Planck-Institut fuer biophysikalische Chemie (1)
- CERN (1)
ResearcherID
- D-1250-2010 (1)
- N-7500-2014 (1)
Interaction between light and matter generates optical nonlinearities, which are particularly pronounced in the quantum strong coupling regime. When a single bosonic mode couples to a single fermionic mode, a Jaynes-Cummings (JC) ladder is formed, which we realize here using cavity photons and quantum dot excitons. We measure and model the coherent anharmonic response of this strongly coupled exciton-cavity system at resonance. Injecting two photons into the cavity, we demonstrate a \(\sqrt 2\) larger polariton splitting with respect to the vacuum Rabi splitting. This is achieved using coherent nonlinear spectroscopy, specifically four-wave mixing, where the coherence between the ground state and the first (second) rung of the JC ladder can be interrogated for positive (negative) delays. With increasing excitation intensity and thus rising average number of injected photons, we observe spectral signatures of the quantum-to-classical crossover of the strong coupling regime.
We report a detailed experimental and theoretical study of the electronic structure of \(Mo_{1-x}Re_x\) random alloys. We have measured electronic band dispersions for clean and hydrogen-covered \(Mo_{1-x}Re_x\) ( 110) with x = 0-0.25 using angle-resolved photoemission spectroscopy. Our results suggest that the bulk and most surface electronic bands shift relative to the Fermi level systematically and approximately rigidly with Re concentration. We distinguish and quantify two contributions to these shifts: a raise of the Fermi energy and an increase of the overall bandwidth. Alloy bands calculated using the first-principles Korringa-Kohn-Rostoker coherent-potential-approximation method accurately predict both of these effects. As derived from the rigid band model, the Fermi energy shift is inversely related to the bulk density of states in this energy region. Using our results, we also characterize an electronic topological transition of the bulk Fermi surface and relate this to bulk transport properties. Finally, we distinguish effects beyond the rigid band approximation: a highly surface-localized state and a composition-dependent impact of the spin-orbit interaction.
Carbonaceous aerosols are responsible for large uncertainties in climate models, degraded visibility, and adverse health effects. The Carbonaceous Aerosols and Radiative Effects Study (CARES) was designed to study carbonaceous aerosols in the natural environment of the Central Valley, California, and learn more about their atmospheric formation and aging. This paper presents results from spectro-microscopic measurements of carbonaceous particles collected during CARES at the time of a pollution accumulation event (27-29 June 2010), when in situ measurements indicated an increase in the organic carbon content of aerosols as the Sacramento urban plume aged. Computer-controlled scanning electron microscopy coupled with an energy dispersive X-ray detector (CCSEM/EDX) and scanning transmission X-ray microscopy coupled with near-edge X-ray absorption spectroscopy (STXM/NEXAFS) were used to probe the chemical composition and morphology of individual particles. It was found that the mass of organic carbon on individual particles increased through condensation of secondary organic aerosol. STXM/NEXAFS indicated that the number fraction of homogenous organic particles lacking inorganic inclusions (greater than similar to 50 nm equivalent circular diameter) increased with plume age, as did the organic mass per particle. Comparison of the CARES spectro-microscopic dataset with a similar dataset obtained in Mexico City during the MILAGRO campaign showed that fresh particles in Mexico City contained three times as much carbon as those sampled during CARES. The number fraction of soot particles at the Mexico City urban site (ranging from 16.6 to 47.3 %) was larger than at the CARES urban site (13.4-15.7%), and the most aged samples from CARES contained fewer carbon-carbon double bonds. Differences between carbonaceous particles in Mexico City and California result from different sources, photochemical conditions, gas phase reactants, and secondary organic aerosol precursors. The detailed results provided by these spectro-microscopic measurements will allow for a comprehensive evaluation of aerosol process models used in climate research.
Wachstum und Charakterisierung von Quantenpunkt-Mikrotürmchen mit adiabatischer Modenanpassung
(2013)
Verschiedene Konzepte zur Realisierung einer geeigneten Umgebung für Licht-
Materie-Wechselwirkung konkurrieren um Anerkennung und eine ständige Optimierung
der Systemparameter findet statt. Das Konzept von Mikrotürmchen scheint
prädestiniert, da es viele anwendungsfreundliche Eigenschaften in sich vereint. Allerdings
stellt die drastische Abnahme des Q Faktors für kleiner werdende Durchmesser
d einen wesentlichen Limitierungsfaktor dieser Strukturen dar. Für viele Anwendungen
resultiert daraus ein Kompromiss aus hohem Q Faktor und kleinem
Modenvolumen der Strukturen, wodurch das volle Potential des Resonatorsystems
nicht ausgeschöpft werden kann. Ziel dieser Arbeit war es, die drastische Abnahme
des Q Faktors von Mikrotürmchen mit Durchmessern um 1μm aufzuheben und
dadurch Resonatoren mit d < 1μm für ausgeprägte Licht-Materie-Wechselwirkung
herzustellen.
Dazu wurde erstmalig beabsichtigt eine Modenanpassung in Mikrotürmchen vorgenommen.
Mittels Molekularstrahlepitaxie konnte eine Übergangsregion, bestehend
aus drei Segmenten, in diese Strukturen implementiert und so ein adiabatischer
Modenübergang zwischen der aktiven Mittelschicht und den Spiegelbereichen
vorgenommen werden. Der positive Einfluss dadurch ergab sich in einer signifikanten
Verbesserung des gemessenen Q Faktors für Durchmesser unter 1μm.
Für d = 0.85μm konnte ein Q Faktor von 14 400 bestimmt werden. Dies stellt damit
den höchsten je gemessenen Wert für Mikrotürmchen im Submikrometerbereich
dar. Dadurch wird ein Bereich mit Modenvolumina < 3 kubischen Wellenlängen erschlossen und ausgeprägte Wechselwirkungseffekte im Mikrotürmchensystem sind zu erwarten. Starke
Quantenpunkt-Licht-Kopplung konnte in diesen Strukturen nachgewiesen werden.
Die höchste Vakuum-Rabiaufspaltung betrug 85μeV und die Visibilität wurde zu
0.41 bestimmt. Im Zuge der weiteren Optimierung der Systemparameter für die starke
Kopplung wurde ein ex-situ Ausheilschritt auf die verwendete Quantenpunktsorte
angewendet. In magnetooptischen Untersuchungen konnte damit eine Verdopplung
der mittleren Oszillatorstärke auf einen Wert von 12 abgeschätzt werden.
Weiter konnte in adiabatischen Mikrotürmchen über einen großen Durchmesserbereich
von 2.25 bis 0.95μm eindeutiger Laserbetrieb des Quantenpunktensembles
nachgewiesen werden. Dabei konnte eine kontinuierliche Reduzierung der Laserschwelle
von über zwei Größenordnungen für kleiner werdende Durchmesser beobachtet
werden. Für Durchmesser < 1.6μm betrug der Beta-Faktor der Mikrolaser in
etwa 0.5. Sie zeigten damit beinahe schwellenloses Verhalten.
Zuletzt wurde der elektrische Betrieb von adiabatischen Mikrotürmchen gezeigt. Dafür
wurde eine dotierte Struktur mit adiabatischem Design hergestellt. Im Vergleich
zur undotierten Struktur fielen die gemessenen Q Faktoren in etwa um 5 000 geringer
aus. Die spektralen Eigenschaften sowohl des Resonators als auch einzelner
Quantenpunktlinien zeigten vernachlässigbare Abhängigkeit der Anregungsart (optisch
oder elektrisch) und zeugen von einem erfolgreichen Konzept zum elektrischen
Betrieb der Bauteile. Zeitaufgelöste Messungen erlaubten die Beobachtung von interessanten
Dynamiken der Rekombination von Ladungsträgern in den Proben. Als
Ursache dafür wurde ein hohes intrinsisches Feld, welches auf Grund des Designs
der Schichtstruktur entsteht, identifiziert. Weiter zeigte sich, dass sich das interne
Feld durch Anregungsart und extern angelegte Spannungen manipulieren lässt.
Planar microcavities with distributed Bragg reflectors (DBRs) host, besides confined optical modes, also mechanical resonances due to stop bands in the phonon dispersion relation of the DBRs. These resonances have frequencies in the 10- to 100-GHz range, depending on the resonator's optical wavelength, with quality factors exceeding 1,000. The interaction of photons and phonons in such optomechanical systems can be drastically enhanced, opening a new route towards the manipulation of light. Here we implemented active semiconducting layers into the microcavity to obtain a vertical-cavity surface-emitting laser (VCSEL). Thereby, three resonant excitations--photons, phonons and electrons--can interact strongly with each other providing modulation of the VCSEL laser emission: a picosecond strain pulse injected into the VCSEL excites long-living mechanical resonances therein. As a result, modulation of the lasing intensity at frequencies up to 40 GHz is observed. From these findings, prospective applications of active optomechanical resonators integrated into nanophotonic circuits may emerge.
Here we report on a combined experimental and theoretical study on the structural and electronic properties of a monolayer of Copper-Phthalocyanine (CuPc) on the Au(1 1 0) surface. Low-energy electron diffraction reveals a commensurate overlayer unit cell containing one adsorbate species. The azimuthal alignment of the CuPc molecule is revealed by comparing experimental constant binding energy (kxky)-maps using angle-resolved photoelectron spectroscopy with theoretical momentum maps of the free molecule's highest occupied molecular orbital (HOMO). This structural information is confirmed by total energy calculations within the framework of van-der-Waals corrected density functional theory. The electronic structure is further analyzed by computing the molecule-projected density of states, using both a semi-local and a hybrid exchange-correlation functional. In agreement with experiment, the HOMO is located about 1.2 eV below the Fermi-level, while there is no significant charge transfer into the molecule and the CuPc LUMO remains unoccupied on the Au(1 1 0) surface.
In this thesis, thin-film solar cells on the basis of Cu(In,Ga)(S,Se)2 (CIGSSe) were investigated.
Until today, most high efficient CIGSSe-based solar cells use a toxic and wetchemical deposited CdS buffer layer, which doesn’t allow a dry inline production. However, a promising and well-performing alternative buffer layer, namely indium sulfide, has been found which doesn’t comprise these disadvantages. In order to shed light on these well-performing devices, the surfaces and in particular the interfaces which play a major role for the charge carrier transport are investigated in the framework of this thesis. Both, the chemical and electronic properties of the solar cells’ interfaces were characterized.
In case of the physical vapor deposition of an InxSy-based buffer layer, the cleaning step of the CdS chemical-bath deposition is not present and thus changes of the absorber surface have to be taken into account. Therefore, adsorbate formation, oxidation, and segregation of absorber elements in dependence of the storing temperature and the humidity are investigated in the first part of this thesis.
The efficiencies of CIGSSe-based solar cells with an InxSy buffer layer depend on the nominal indium concentration x and display a maximum for x = 42 %. In this thesis, InxSy samples with a nominal indium concentration of 40.2% ≤ x ≤ 43.2% were investigated by surface-sensitive and surface-near bulk-sensitive techniques, namely with photoemission spectroscopy (PES) and x-ray emission spectroscopy (XES). The surfaces of the films were found to be sulfur-poor and indium-rich in comparison with stoichiometric In2S3. Moreover, a direct determination of the band alignment at the InxSy/CISSe interface in dependence of the nominal indium concentration x was conducted with the help of PES and inverse PES (IPES) and a flat band alignment was found for x = 42 %.
In order to study the impact of a heat treatment as it occurs during subsequent cell process steps, the indium sulfide-buffered absorbers were annealed for 30 minutes under UHV conditions at 200 °C after the initial data set was taken. Besides a reported enhanced solar cell performance, a significant copper diffusion from the absorber into the buffer layer takes place due to the thermal treatment. Accordingly, the impact of the copper diffusion on the hidden InxSy/CISSe interface was discussed and for x = 40.2% a significant cliff (downwards step in the conduction band) is observed. For increasing x, the alignment in the conduction band turns into a small upwards step (spike) for the region 41% ≤ x ≤ 43.2%. This explains the optimal solar cell performance for this indium contents.
In a further step, the sodium-doped indium sulfide buffer which leads to significantly higher efficient solar cells was investigated. It was demonstrated by PES/IPES that the enhanced performance can be ascribed to a significant larger surface band gap in comparison with undoped InxSy. The occurring spike in the Na:InxSy/CISSe band alignment gets reduced due to a Se diffusion induced by the thermal treatment. Furthermore, after the thermal treatment the sodium doped indium sulfide layer experiences a copper diffusion which is reduced by more than a factor of two compared to pure InxSy.
Next, the interface between the Na:InxSy buffer layer and the i-ZnO (i = intrinsic, non-deliberately doped), as a part of the transparent front contact was analyzed. The i-ZnO/Na:InxSy interface shows significant interdiffusion, leading to the formation of, e.g., ZnS and hence to a reduction of the nominal cliff in the conduction band alignment.
In the last part of this thesis, the well-established surface-sensitive reflective electron energy loss spectroscopy (REELS) was utilized to study the CIGSSe absorber, the InxSy buffer, and annealed InxSy buffer surfaces. By fitting the characteristic inelastic scattering cross sections λK(E) with Drude-Lindhard oscillators the dielectric function was identified. The determined dielectric functions are in good agreement with values from bulk-sensitive optical measurements on indium sulfide layers. In contrast, for the chalcopyrite-based absorber significant differences appear. In particular, a substantial larger surface band gap of the CIGSSe surface of E^Ex_Gap = (1.4±0.2) eV in comparison with bulk values is determined. This provides for the first time an independent verification of earlier PES/IPES results. Finally, the electrons’ inelastic mean free paths l for the three investigated surfaces are compared for different primary energies with theoretical values and the universal curve.
The possibility of investigating macroscopic coherent quantum states in polariton condensates and of engineering polariton landscapes in semiconductors has triggered interest in using polaritonic systems to simulate complex many-body phenomena. However, advanced experiments require superior trapping techniques that allow for the engineering of periodic and arbitrary potentials with strong on-site localization, clean condensate formation, and nearest-neighbor coupling. Here we establish a technology that meets these demands and enables strong, potentially tunable trapping without affecting the favorable polariton characteristics. The traps are based on a locally elongated microcavity which can be formed by standard lithography. We observe polariton condensation with non-resonant pumping in single traps and photonic crystal square lattice arrays. In the latter structures, we observe pronounced energy bands, complete band gaps, and spontaneous condensation at the M-point of the Brillouin zone.
Microstructural changes and the understanding of their effect on photocurrent generation are key aspects for improving the efficiency of organic photovoltaic devices. We analyze the impact of a systematically increased amount of the solvent additive diiodooctane (DIO) on the morphology of PBDTTT-C:PC71BM blends and related changes in free carrier formation and recombination by combining surface imaging, photophysical and charge extraction techniques. We identify agglomerates visible in AFM images of the 0% DIO blend as PC71BM domains embedded in an intermixed matrix phase. With the addition of DIO, a decrease in the size of fullerene domains along with a demixing of the matrix phase appears for 0.6% and 1% DIO. Surprisingly, transient absorption spectroscopy reveals an efficient photogeneration already for the smallest amount of DIO, although the largest efficiency is found for 3% DIO. It is ascribed to a fine-tuning of the blend morphology in terms of the formation of interpenetrating donor and acceptor phases minimizing geminate and nongeminate recombination as indicated by charge extraction experiments. An increase in the DIO content to 10% adversely affects the photovoltaic performance, most probably due to an inefficient free carrier formation and trapping in a less interconnected donor-acceptor network.
Entwicklung klinischer Methoden zur Quantifizierung der longitudinalen Relaxationszeit T1 in der MRT
(2014)
Die Aufgabenstellung in der vorliegenden Arbeit bestand in der Entwicklung und Umsetzung neuer T1-Quantifizierungsverfahren, die zuverlässig in der klinischen Routine angewendet werden können. Die ausgearbeiteten Techniken umfassten dabei zwei Hauptarbeitsschwerpunkte.
Zum einen die Implementierung einer neuartigen dynamischen T1- Thermometriemethode für MR-Sicherheitsuntersuchungen medizinischer Geräte und Implantate, wie beispielsweise Kathetern oder Herzschrittmachern, und zum anderen die Entwicklung eines robusten kardialen T1-Mapping-Verfahrens, welches auch bei stärker erkrankten Patienten mit eingeschränkter Atemanhaltefähigkeit stabil anwendbar ist.
Mit der entwickelten kombinierten Heiz- und T1-Thermometriesequenz konnte ein neues Verfahren präsentiert werden, mit dem ein zu untersuchendes medizinisches Gerät oder Implantat kontrolliert erwärmt und die Temperaturänderung zeitgleich präzise erfasst werden kann. Dabei war es möglich, die HF-induzierte Erwärmung der metallischen Beispielimplantate sowohl in homogenem Gel als auch in inhomogenem Muskelgewebe exakt und ortsaufgelöst zu quantifizieren. Die MR-technisch errechneten Temperaturwerte zeigten dabei eine sehr gute Übereinstimmung zu den ermittelten Referenzwerten mit einer Temperaturabweichung von meist weniger als 1K. Die Ergebnisse zeigen, dass es mit der präsentierten Methode möglich ist, die räumliche Temperaturverteilung in einem großen Bereich mit einer einzigen Messung quantitativ zu erfassen. Dies ist neben der Nichtinvasivität der Methode der größte Vorteil im Vergleich zu der Einzelpunktmessung mittels eines bei solchen Messungen sonst zumeist verwendeten fluoroptischen Temperatursensors. Bei gestreckten Implantaten kann demnach idealerweise das gesamte Objekt während einer einzigen Messung auf potentielle Temperaturänderungen oder sogenannte Hotspots untersucht werden, was bei der Verwendung von Temperatursensoren lediglich mit großem Zeitaufwand möglich ist, da hier die Temperatur jeweils nur punktuell erfasst werden kann. Im Vergleich zu anderen publizierten MR-Thermometrieverfahren, welche auf der PRF-Technik basieren, bietet die hier präsentierte Methode vor allem den Vorteil, dass hiermit auch eine präzise Temperaturquantifizierung in inhomogenem biologischem Gewebe mit starken Suszeptibilitätsunterschieden wie beispielsweise zwischen Herz und Lunge möglich ist. Somit stellt die Methode ein leistungsstarkes Hilfsmittel für nicht-invasive MR-Sicherheitsuntersuchungen nicht nur an medizinischen Implantaten sondern beispielsweise auch für MR-geführte Interventionen dar.
Mit der entwickelten kardialen T1-Mapping-Sequenz TRASSI wurde eine leistungsstarke Methode zur exakten und hoch aufgelösten Generierung kardialer T1-Karten in äußerst kurzer Messzeit (< 6 s) vorgestellt. Durch ihre außerordentliche Robustheit sowohl gegenüber Bildartefakten als auch Herzrhythmusstörungen während der Datenakquisition bietet die Sequenz deutlich verbesserte Möglichkeiten für die Diagnostik verschiedener Herzerkrankungen. Aufgrund der sehr kurzen Akquisitionszeit wird insbesondere auch die Generierung von T1-Karten bei schwer erkrankten Patienten mit kurzer Atemanhaltefähigkeit ermöglicht. Im Vergleich zu derzeit üblicherweise verwendeten alternativen Verfahren wie etwa MOLLI, konnten die T1-Karten mit vergleichbarer Bildauflösung in bis zu 70% kürzerer Messzeit akquiriert werden. Die Ergebnisse der durchgeführten Phantommessungen belegen außerdem, dass die Methode exaktere T1-Werte liefert als dies beispielsweise mit MOLLI möglich ist. Des Weiteren weist TRASSI im Gegensatz zu MOLLI keine T1-Abhängigkeit von der Herzrate auf, wodurch die vorgestellte Technik besonders für diagnostische Studien geeignet ist, welche eine sehr hohe Genauigkeit und Reproduzierbarkeit im Zeitverlauf oder zwischen verschiedenen Patienten erfordern.
Mit TRASSI konnten die Strukturen des Herzens bei den durchgeführten in vivo Untersuchungen durchweg mit scharfen Kanten und ohne Bewegungsartefakte dargestellt werden. Dabei wurde unabhängig von der Herzrate und der Bildebene stets eine sehr gute Bildqualität erreicht. Der Hauptgrund hierfür ist vermutlich in der sehr kurzen Akquisitionszeit und der radialen Datenaufnahme zu sehen. Beide Verfahren reduzieren Artefakte aufgrund von Bewegungen wie beispielsweise Herzschlag und Atmung erheblich. Die aufgenommenen T1-Karten zeigen bei allen Probanden und Patienten eine gute diagnostische Bildqualität. So konnten auch die infarzierten Bereiche bei Patienten mit Myokardinfarkt deutlich visualisiert und quantitativ erfasst werden. Nochmals hervorzuheben ist die beobachtete besondere Robustheit der TRASSI Methode gegenüber
Artefakten beziehungsweise T1-Quantifizierungsfehlern bei Patienten mit Herzrhythmusstörungen. Auch bei untersuchten Patienten mit starken Arrhythmien während der Bildgebung konnte eine sehr gute Bildqualität und Genauigkeit der errechneten T1-Karten erreicht werden. Die Ergebnisse der Extrazellularvolumen-Quantifizierung zeigen zudem, dass mittels TRASSI auch weiterführende diagnostische Methoden entwickelt und angewandt werden können. Dabei konnten durch Rückrechnung hochaufgelöster und präziser Extrazellularvolumen-Karten beispielsweise Infarktbereiche deutlich visualisiert und signifikante Unterschiede zwischen akut und chronisch infarziertem Herzmuskelgewebe nicht nur identifiziert sondern auch quantitativ charakterisiert werden. Somit ist diese Methode insbesondere für eine potentielle Differenzierung zwischen reversibel und irreversibel geschädigten Herzarealen interessant.
Für die Zukunft ist es wünschenswert, weitergehende Untersuchungen an verschiedenen spezifischen Herzerkrankungen vorzunehmen. Zu solchen Erkrankungen gehören beispielsweise die Herzmuskelentzündung (Myokarditis) oder Herzklappenerkrankungen. Diese Krankheitsbilder sind hinsichtlich einer möglichen transienten oder permanenten Schädigung des Herzmuskels mit den bisher verfügbaren Verfahren nur sehr schwer oder lediglich im weit fortgeschrittenen Stadium exakt diagnostizierbar. Die vorgestellte TRASSI-Sequenz bietet hier eine gute Möglichkeit für eine frühzeitige Erkennung der Auswirkungen solcher Erkrankungen auf den Herzmuskel. Weiterführende Untersuchungen der TRASSI-Methode zu deren Robustheit gegenüber spezifischen Herzrhythmusstörungen und ein umfassender Vergleich zum bereits etablierten MOLLI-Verfahren könnten darüber hinaus die Alltagstauglichkeit von TRASSI weiter spezifizieren und den Weg in die klinische Routine ebnen. Die bereits dargelegten positiven Ergebnisse des Verfahrens lassen vermuten, dass TRASSI potentiell ein sehr gutes nicht-invasives Diagnoseverfahren für verschiedenste Herzerkrankungen darstellt. Im Vergleich zu bereits bestehenden Techniken liegen die Vorteile der TRASSI-Methode nach den bisher vorliegenden Ergebnissen zusammenfassend vor allem in der Generierung diagnostisch verlässlicherer T1-Werte bei gleichzeitig verringerter Messzeit, wodurch das Verfahren insbesondere auch für schwer erkrankte Patienten mit starken Arrhythmien und eingeschränkter Atemanhaltefähigkeit geeignet ist.
TRASSI ist darüber hinaus aber auch für MR-Untersuchungen im Hochfeld besser geeignet als entsprechende bSSFP-basierende Verfahren wie beispielsweise MOLLI. Dies liegt vor allem daran, dass TRASSI eine Gradientenecho-basierte Bildgebungsmethode ist und somit eine niedrige spezifische Absorptionsrate aufweist. Zudem sind Gradientenecho-Sequenzen allgemein weniger empfindlich gegenüber Suszeptibilitätsartefakten, so dass beispielsweise metallische Implantate bei Patienten sich weniger störend auf die erreichbare Bildqualität auswirken.
In der vorliegenden Arbeit wurde sowohl eine exakte T1-Thermometriesequenz als auch eine sehr schnelle und präzise kardiale T1-Mapping-Methode vorgestellt. Für zukünftige Arbeiten ist es wünschenswert, beide Sequenzen bzw. deren Mechanismen zu vereinen und eine Temperaturquantifizierung am Herzen praktisch durchzuführen. Dies wäre zum einen für MR-Sicherheitsuntersuchungen von Schrittmacherelektroden in vivo vorteilhaft, und zum anderen wäre hiermit eine direkte Erfolgskontrolle während einer Katheterablation realisierbar. Eine solche Ablationsbehandlung könnte durch eine genaue Lokalisierung des behandelten - also erhitzten - Herzareals sehr viel präziser durchgeführt werden, wodurch auch bei komplexeren Ablationen die Behandlungserfolge erhöht werden könnten. In einer ersten Veröffentlichung hierzu konnte bereits gezeigt werden, dass eine MR-gestützte Katheterablation die Heilungs- und Erfolgsaussichten des Eingriffes steigern kann. Dieses Verfahren könnte potentiell mit Hilfe einer Echtzeittemperaturüberwachung basierend auf dem TRASSI-Verfahren noch weiter verbessert werden.
In Zusammenfassung wurden in dieser Arbeit zwei neue T1-Quantifizierungsverfahren entwickelt und vorgestellt, die voraussichtlich zuverlässig im klinischen Alltag angewendet werden können und neue nicht-invasive diagnostische Möglichkeiten eröffnen. Die implementierten Sequenzen ermöglichen dabei zum einen eine exakte Temperaturquantifizierung und zum anderen ein präzises kardiales T1-Mapping. Beide Verfahren versprechen dabei robuste und reproduzierbare Ergebnisse und könnten in Zukunft den Weg in die klinische Routine finden und so bei einer fundierten Diagnostik verschiedenster Herzerkrankungen behilflich sein.