Klinik und Poliklinik für Nuklearmedizin
Refine
Has Fulltext
- yes (244)
Is part of the Bibliography
- yes (244)
Year of publication
Document Type
- Journal article (177)
- Doctoral Thesis (52)
- Conference Proceeding (9)
- Preprint (6)
Keywords
- PET (35)
- Positronen-Emissions-Tomografie (27)
- positron emission tomography (27)
- prostate cancer (19)
- CXCR4 (18)
- PET/CT (16)
- theranostics (16)
- PSMA (13)
- PRRT (11)
- SPECT (11)
Institute
- Klinik und Poliklinik für Nuklearmedizin (244)
- Medizinische Klinik und Poliklinik I (25)
- Medizinische Klinik und Poliklinik II (25)
- Pathologisches Institut (19)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (17)
- Deutsches Zentrum für Herzinsuffizienz (DZHI) (15)
- Urologische Klinik und Poliklinik (12)
- Neurologische Klinik und Poliklinik (11)
- Institut für Pharmazie und Lebensmittelchemie (8)
- Graduate School of Life Sciences (7)
Schriftenreihe
Sonstige beteiligte Institutionen
- Johns Hopkins School of Medicine (18)
- Johns Hopkins University School of Medicine (5)
- Johns Hopkins School of Medicine, Baltimore, MD, U.S. (4)
- Department of Biomedical Imaging, National Cerebral and Cardiovascular Research Center, Suita, Japan (2)
- Division of Medical Technology and Science, Department of Medical Physics and Engineering, Course of Health Science, Osaka University Graduate School of Medicine, Suita Japan (2)
- Institut for Molecular Biology and CMBI, Department of Genomics, Stem Cell Biology and Regenerative Medicine, Leopold-Franzens-University Innsbruck, Innsbruck, Austria (2)
- Johns Hopkins School of Medicine, The Russell H Morgan Department of Radiology and Radiological Science, Baltimore, MD, USA (2)
- Bundeswehr Institute of Radiobiology affiliated to the University of Ulm, Munich, Germany (1)
- CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - the development agency of the Brazilian Federal Government (1)
- DAAD - Deutscher Akademischer Austauschdienst (1)
\(^{11}\)C-methionine (\(^{11}\)C-MET) is a new positron emission tomography (PET) tracer for the assessment of disease activity in multiple myeloma (MM) patients, with preliminary data suggesting higher sensitivity and specificity than \(^{18}\)F-fluorodeoxyglucose (\(^{18}\)F-FDG). However, the value of tumor burden biomarkers has yet to be investigated. Our goals were to corroborate the superiority of \(^{11}\)C-MET for MM staging and to compare its suitability for the assessment of metabolic tumor burden biomarkers in comparison to \(^{18}\)F-FDG. Twenty-two patients with newly diagnosed, treatment-naïve symptomatic MM who had undergone \(^{11}\)C-MET and \(^{18}\)F-FDG PET/CT were evaluated. Standardized uptake values (SUV) were determined and compared with total metabolic tumor volume (TMTV) for both tracers: total lesion glycolysis (TLG) and total lesion \(^{11}\)C-MET uptake (TLMU). PET-derived values were compared to Revised International Staging System (R-ISS), cytogenetic, and serologic MM markers such as M component, beta 2 microglobulin (B2M), serum free light chains (FLC), albumin, and lactate dehydrogenase (LDH). In 11 patients (50%), \(^{11}\)C-MET detected more focal lesions (FL) than FDG (p < 0.01). SUVmax, SUVmean, SUVpeak, TMTV, and TLMU were also significantly higher in \(^{11}\)C-MET than in \(^{18}\)F-FDG (p < 0.05, respectively). \(^{11}\)C-MET PET biomarkers had a better correlation with tumor burden (bone marrow plasma cell infiltration, M component; p < 0.05 versus p = n.s. respectively). This pilot study suggests that \(^{11}\)C-MET PET/CT is a more sensitive marker for the assessment of myeloma tumor burden than \(^{18}\)F-FDG. Its implications for prognosis evaluation need further investigation.
11C-Methionin (11C-MET) ist ein alternatives Radiopharmakon für die Positronen-Emissions-Tomographie (PET) zur Beurteilung der Krankheitsaktivität bei Patient/-innen mit Multiplem Myelom (MM). Frühe Daten legen eine höhere Sensitivität und Spezifität als bei dem bisherigen Standardtracer 18F-Fluordesoxyglucose (18F-FDG) nahe. Es fehlen bislang jedoch Untersuchungen, welche die neuen, aus PET-Daten abgeleiteten Parameter „metabolic tumor volume“ (MTV) und „total lesion glycolysis / total lesion methionin uptake“ (TLG/TLMU) in diesen Vergleich miteinbeziehen. In früheren Studien konnte bereits eine prognostische Aussagekraft dieser neuen Imaging Parameter für die 18F-FDG-PET/CT gezeigt werden. Das Ziel dieser bizentrischen Studie war es, die sich im Rahmen bisheriger Studienergebnisse andeutende Überlegenheit von 11C-MET für das Staging des MM zu überprüfen und seine Eignung für die Bewertung von metabolischen Imaging Parametern im Vergleich zu 18F-FDG zu untersuchen.
Zweiundzwanzig Patient/-innen mit neu diagnostiziertem unbehandelten MM, davon 15 Patient/-innen des Universitätsklinikums Würzburg und sieben Patient/-innen der Clinica Universidad de Navarra in Pamplona, die eine doppelte PET/CT-Bildgebung unter Verwendung der beiden Tracer 11C-MET und 18F-FDG innerhalb eines Zeitraums von maximal 14 Tagen erhalten hatten, wurden retrospektiv durch den Doktoranden (Oliver Viering) sowie eine nuklearmedizinische Assistenzärztin (Maria I. Morales-Lozano) und im Anschluss durch je eine PET/CT-Expert/-in des Universitätsklinikums Würzburg (Constantin Lapa) und der Clinica Universidad de Navarra (Maria J. Garcia-Velloso) untersucht.
Hierfür wurden die 18F-FDG- und 11C-MET-PET/CT-Aufnahmen einer dreidimensionalen Analyse mit Hilfe des "PET/CT-Viewer Beth Israel for FIJI" unterzogen. Diese open source Software ermöglichte die Berechnung von SUVmean, SUVmax und SUVpeak sowie der neuen Imaging Biomarker MTV und TLG/TLMU. Die genannten PET-Parameter wurden mit klinischen und laborchemischen Parametern (Hämoglobin, Calcium, Kreatinin, CRP, β2-Mikroglobulin, Albumin, M-Gradient/M-Protein, Knochenmarkinfiltration, LDH, freier Leichtketten-quotient, R-ISS, zytogenetisches Risiko) korreliert, welche in früheren Studien als prognostisch relevante Parameter der Myelom-Erkrankung identifiziert worden waren.
Bei elf der 22 Patient/-innen (50 %) wurden mithilfe von 11C-MET mehr fokale Läsionen als mit 18F-FDG nachgewiesen (p < 0,01), daneben konnte bei einer größeren Zahl von Patient/-innen eine diffuse Knochenmarkinfiltration durch die malignen Plasmazellen identifiziert werden (11C-MET: 19, 18F-FDG: 12). Sowohl die SUV-Parameter (SUVmean, SUVmax und SUVpeak) als auch die neuen Imaging Parameter (TMTV und TLG/TLMU) waren bei der 11C-MET- signifikant höher als bei der 18F-FDG-PET/CT (p < 0,05).
In Bezug auf die neuen Imaging Parameter zeigten sich für 11C-MET häufiger signifikante Korrelationen mit den prognostisch relevanten klinischen und laborchemischen Parametern als für 18F-FDG. Bei TMTV konnten für die 11C-MET-PET/CT signifikante Korrelationen für β2-Mikroglobulin (p = 0,006), die M-Komponente (p = 0,003), den Grad der Knochenmarkinfiltration (p = 0,007) und das Serum-Hämoglobin (p = 0,016) gefunden werden, wohingegen sich bei 18F-FDG lediglich eine signifikante Korrelation für β2-Mikroglobulin (p = 0,044) zeigte. In Bezug auf die TLG/TLMU konnten bei 18F-FDG keine signifikanten Korrelationen zwischen TLG und den klinischen und laborchemischen Parametern nachgewiesen werden. Bei 11C-MET zeigten sich hingegen signifikante Korrelationen zwischen dem TLMU und der Kalzium-Konzentration im Serum (p = 0,028), dem β2-Mikroglobulin (p = 0,047), der M-Komponente (p = 0,033) und dem Grad der Knochenmarkinfiltration (p = 0,041).
Trotz zahlreicher Limitationen dieser Arbeit, wie etwa der geringen Patientenzahl und des retrospektiven Charakters der Auswertung bekräftigt auch diese Studie in Übereinstimmung mit den bisherigen Studienergebnissen, dass 11C-MET im Vergleich zu 18F-FDG ein sensitiverer Marker für die Beurteilung der Myelom-Tumorlast sein könnte. Eine Untersuchung der prognostischen Aussagekraft von 11C-MET in Bezug auf progressionsfreies- und Gesamtüberleben im Zuge der primären Bildgebung der Erkrankung war aufgrund der kurzen Nachbeobachtungszeit und der Heterogenität der Behandlung, welche die Patient/-innen im Anschluss an die Staging-Untersuchungen erhalten hatten, nicht möglich und muss im Rahmen zukünftiger, insbesondere prospektiver Studien weiter untersucht werden.
Prostate-specific membrane antigen (PSMA)-targeted PET imaging for prostate cancer with \(^{68}\)Ga-labeled compounds has rapidly become adopted as part of routine clinical care in many parts of the world. However, recent years have witnessed the start of a shift from \(^{68}\)Ga- to \(^{18}\)F-labeled PSMA-targeted compounds. The latter imaging agents have several key advantages, which may lay the groundwork for an even more widespread adoption into the clinic. First, facilitated delivery from distant suppliers expands the availability of PET radiopharmaceuticals in smaller hospitals operating a PET center but lacking the patient volume to justify an onsite \(^{68}\)Ge/\(^{68}\)Ga generator. Thus, such an approach meets the increasing demand for PSMA-targeted PET imaging in areas with lower population density and may even lead to cost-savings compared to in-house production. Moreover, \(^{18}\)F-labeled radiotracers have a higher positron yield and lower positron energy, which in turn decreases image noise, improves contrast resolution, and maximizes the likelihood of detecting subtle lesions. In addition, the longer half-life of 110 min allows for improved delayed imaging protocols and flexibility in study design, which may further increase diagnostic accuracy. Moreover, such compounds can be distributed to sites which are not allowed to produce radiotracers on-site due to regulatory issues or to centers without access to a cyclotron. In light of these advantageous characteristics, \(^{18}\)F-labeled PSMA-targeted PET radiotracers may play an important role in both optimizing this transformative imaging modality and making it widely available. We have aimed to provide a concise overview of emerging \(^{18}\)F-labeled PSMA-targeted radiotracers undergoing active clinical development. Given the wide array of available radiotracers, comparative studies are needed to firmly establish the role of the available \(^{18}\)F-labeled compounds in the field of molecular PCa imaging, preferably in different clinical scenarios.
Chemokine receptor-4 (CXCR4) has been reported to be overexpressed in glioblastoma (GBM) and to be associated with poor survival. This study investigated the feasibility of non-invasive CXCR4-directed imaging with positron emission tomography/computed tomography (PET/CT) using the radiolabelled chemokine receptor ligand \(^{68}\)Ga-Pentixafor.
15 patients with clinical suspicion on primary or recurrent glioblastoma (13 primary, 2 recurrent tumors) underwent \(^{68}\)Ga-Pentixafor-PET/CT for assessment of CXCR4 expression prior to surgery. O-(2-\(^{18}\)F-fluoroethyl)-L-tyrosine (\(^{18}\)F-FET) PET/CT images were available in 11/15 cases and were compared visually and semi-quantitatively (SUV\(_{max}\), SUV\(_{mean}\)). Tumor-to-background ratios (TBR) were calculated for both PET probes. \(^{68}\)Ga-Pentixafor-PET/CT results were also compared to histological CXCR4 expression on neuronavigated surgical samples.
\(^{68}\)Ga-Pentixafor-PET/CT was visually positive in 13/15 cases with SUV\(_{mean}\) and SUV\(_{max}\) of 3.0±1.5 and 3.9±2.0 respectively. Respective values for \(^{18}\)F-FET were 4.4±2.0 (SUV\(_{mean}\)) and 5.3±2.3 (SUV\(_{max}\)). TBR for SUV\(_{mean}\) and SUV\(_{max}\) were higher for \(^{68}\)Ga-Pentixafor than for \(^{18}\)F-FET (SUV\(_{mean}\) 154.0±90.7 vs. 4.1±1.3; SUV\(_{max}\) 70.3±44.0 and 3.8±1.2, p<0.01), respectively. Histological analysis confirmed CXCR4 expression in tumor areas with high \(^{68}\)Ga-Pentixafor uptake; regions of the same tumor without apparent \(^{68}\)Ga-Pentixafor uptake showed no or low receptor expression.
In this pilot study, \(^{68}\)Ga-Pentixafor retention has been observed in the vast majority of glioblastoma lesions and served as readout for non-invasive determination of CXCR4 expression. Given the paramount importance of the CXCR4/SDF-1 axis in tumor biology, \(^{68}\)Ga-Pentixafor-PET/CT might prove a useful tool for sensitive, non-invasive in-vivo quantification of CXCR4 as well as selection of patients who might benefit from CXCR4-directed therapy.
Background
Solitary metastases to the pancreas are rare. Therefore the value of resection in curative intention remains unclear. In the literature there are several promising reports about resection of solitary metastasis to the pancreas mainly of renal origin.
Case presentation
Here we report for the first time on the surgical therapy of a 1.5 cm solitary pancreatic metastasis of an adrenocortical carcinoma. The metastasis occurred almost 6 years after resection of the primary tumor. A partial pancreatoduodenectomy was performed and postoperatively adjuvant mitotane treatment was initiated. During the follow-up of 3 years after surgery no evidence of tumor recurrence occurred.
Conclusion
Resection of pancreatic tumors should be considered, even if the mass is suspicious for metastatic disease including recurrence of adrenocortical cancer.
Purpose
Patient-specific dosimetry is required to ensure the safety of molecular radiotherapy and to predict response. Dosimetry involves several steps, the first of which is the determination of the activity of the radiopharmaceutical taken up by an organ/lesion over time. As uncertainties propagate along each of the subsequent steps (integration of the time–activity curve, absorbed dose calculation), establishing a reliable activity quantification is essential. The MRTDosimetry project was a European initiative to bring together expertise in metrology and nuclear medicine research, with one main goal of standardizing quantitative \(^{177}\)Lu SPECT/CT imaging based on a calibration protocol developed and tested in a multicentre inter-comparison. This study presents the setup and results of this comparison exercise.
Methods
The inter-comparison included nine SPECT/CT systems. Each site performed a set of three measurements with the same setup (system, acquisition and reconstruction): (1) Determination of an image calibration for conversion from counts to activity concentration (large cylinder phantom), (2) determination of recovery coefficients for partial volume correction (IEC NEMA PET body phantom with sphere inserts), (3) validation of the established quantitative imaging setup using a 3D printed two-organ phantom (ICRP110-based kidney and spleen). In contrast to previous efforts, traceability of the activity measurement was required for each participant, and all participants were asked to calculate uncertainties for their SPECT-based activities.
Results
Similar combinations of imaging system and reconstruction lead to similar image calibration factors. The activity ratio results of the anthropomorphic phantom validation demonstrate significant harmonization of quantitative imaging performance between the sites with all sites falling within one standard deviation of the mean values for all inserts. Activity recovery was underestimated for total kidney, spleen, and kidney cortex, while it was overestimated for the medulla.
Conclusion
This international comparison exercise demonstrates that harmonization of quantitative SPECT/CT is feasible when following very specific instructions of a dedicated calibration protocol, as developed within the MRTDosimetry project. While quantitative imaging performance demonstrates significant harmonization, an over- and underestimation of the activity recovery highlights the limitations of any partial volume correction in the presence of spill-in and spill-out between two adjacent volumes of interests.
Background
The GMP-compliant production of radiopharmaceuticals has been performed using disposable units (cassettes) with a dedicated synthesis module. To expand this “plug ‘n’ synthesize” principle to a broader scope of modules we developed a pressure controlled setup that offers an alternative to the usual stepper motor controlled rotary valves. The new concept was successfully applied to the synthesis of N-methyl-[\(^{11}\)C]choline, L-S-methyl-[\(^{11}\)C]methionine and [11C]acetate.
Results
The target gas purification of cyclotron produced [\(^{11}\)C]CO\(_2\) and subsequent conversion to [\(^{11}\)C]MeI was carried out on a TRACERlab Fx C Pro module. The labelling reactions were controlled with a TRACERlab Fx FE module. With the presented modular principle we were able to produce N-methyl-[\(^{11}\)C]choline and L-S-methyl-[\(^{11}\)C]methionine by loading a reaction loop with neat N,N'-dimethylaminoethanol (DMAE) or an ethanol/water mixture of NaOH and L-homocysteine (L-HC), respectively and a subsequent reaction with [\(^{11}\)C]MeI. After 18 min N-methyl-[\(^{11}\)C]choline was isolated with 52% decay corrected yield and a radiochemical purity of > 99%. For L-S-methyl-[\(^{11}\)C]methionine the total reaction time was 19 min reaction, yielding 25% of pure product (> 97%). The reactor design was used as an exemplary model for the technically challenging [\(^{11}\)C]acetate synthesis. The disposable unit was filled with 1 mL MeMgCl (0.75 M) in tetrahydrofuran (THF) bevore [\(^{11}\)C]CO\(_2\) was passed through. After complete release of [\(^{11}\)C]CO\(_2\) the reaction mixture was quenched with water and guided through a series of ion exchangers (H\(^+\), Ag\(^+\) and OH\(^−\)). The product was retained on a strong anion exchanger, washed with water and finally extracted with saline. The product mixture was acidified and degassed to separate excess [\(^{11}\)C]CO\(_2\) before dispensing. Under these conditions the total reaction time was 18 ± 2 min and pure [\(^{11}\)C]acetate (n = 10) was isolated with a decay corrected yield of 51 ± 5%.
Conclusion
Herein, we described a novel single use unit for the synthesis of carbon-11 labelled tracers for preclinical and clinical applications of N-methyl-[\(^{11}\)C]choline, L-S-methyl-[\(^{11}\)C]methionine and [11C]acetate.
The incidence of differentiated thyroid cancer (DTC) is steadily increasing globally. Epidemiologists usually explain this global upsurge as the result of new diagnostic modalities, screening and overdiagnosis as well as results of lifestyle changes including obesity and comorbidity. However, there is evidence that there is a real increase of DTC incidence worldwide in all age groups. Here, we review studies on pediatric DTC after nuclear accidents in Belarus after Chernobyl and Japan after Fukushima as compared to cohorts without radiation exposure of those two countries. According to the Chernobyl data, radiation-induced DTC may be characterized by a lag time of 4–5 years until detection, a higher incidence in boys, in children of youngest age, extrathyroidal extension and distant metastases. Radiation doses to the thyroid were considerably lower by appr. two orders of magnitude in children and adolescents exposed to Fukushima as compared to Chernobyl. In DTC patients detected after Fukushima by population-based screening, most of those characteristics were not reported, which can be taken as proof against the hypothesis, that radiation is the (main) cause of those tumors. However, roughly 80% of the Fukushima cases presented with tumor stages higher than microcarcinomas pT1a and 80% with lymph node metastases pN1. Mortality rates in pediatric DTC patients are generally very low, even at higher tumor stages. However, those cases considered to be clinically relevant should be followed-up carefully after treatment because of the risk of recurrencies which is expected to be not negligible. Considering that thyroid doses from the Fukushima accident were quite small, it makes sense to assess the role of other environmental and lifestyle-related factors in thyroid carcinogenesis. Well-designed studies with assessment of radiation doses from medical procedures and exposure to confounders/modifiers from the environment as e.g., nitrate are required to quantify their combined effect on thyroid cancer risk.