Klinik und Poliklinik für Nuklearmedizin
Refine
Has Fulltext
- yes (246)
Is part of the Bibliography
- yes (246)
Year of publication
Document Type
- Journal article (179)
- Doctoral Thesis (52)
- Conference Proceeding (9)
- Preprint (6)
Keywords
- PET (35)
- Positronen-Emissions-Tomografie (27)
- positron emission tomography (27)
- prostate cancer (19)
- CXCR4 (18)
- PET/CT (16)
- theranostics (16)
- PSMA (13)
- PRRT (11)
- SPECT (11)
Institute
- Klinik und Poliklinik für Nuklearmedizin (246)
- Medizinische Klinik und Poliklinik I (25)
- Medizinische Klinik und Poliklinik II (25)
- Pathologisches Institut (19)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (17)
- Deutsches Zentrum für Herzinsuffizienz (DZHI) (15)
- Urologische Klinik und Poliklinik (12)
- Neurologische Klinik und Poliklinik (11)
- Institut für Pharmazie und Lebensmittelchemie (8)
- Graduate School of Life Sciences (7)
Schriftenreihe
Sonstige beteiligte Institutionen
- Johns Hopkins School of Medicine (18)
- Johns Hopkins University School of Medicine (5)
- Johns Hopkins School of Medicine, Baltimore, MD, U.S. (4)
- Department of Biomedical Imaging, National Cerebral and Cardiovascular Research Center, Suita, Japan (2)
- Division of Medical Technology and Science, Department of Medical Physics and Engineering, Course of Health Science, Osaka University Graduate School of Medicine, Suita Japan (2)
- Institut for Molecular Biology and CMBI, Department of Genomics, Stem Cell Biology and Regenerative Medicine, Leopold-Franzens-University Innsbruck, Innsbruck, Austria (2)
- Johns Hopkins School of Medicine, The Russell H Morgan Department of Radiology and Radiological Science, Baltimore, MD, USA (2)
- Bundeswehr Institute of Radiobiology affiliated to the University of Ulm, Munich, Germany (1)
- CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - the development agency of the Brazilian Federal Government (1)
- DAAD - Deutscher Akademischer Austauschdienst (1)
Die Radiosynoviorthese ist ein etabliertes Therapieverfahren zur Behandlung der Synovialitis.
Da bei der Radiosynoviorthese die Handhabung von radioaktiven β-Strahlern wie Yttrium, Rhenium und Erbium notwendig ist, sind bestimmte Schutzmaßnahmen einzuhalten. Zum Schutze des Patienten wurden Leitlinien aufgestellt, um die Strahlenbelastung so gering wie möglich zu halten. Die Exposition der bei der Vorbereitung und Applikation beteiligten Ärzte, Radiopharmazeuten sowie beteiligten Krankenschwestern bietet Raum für weitere Verbesserungen.
Eine Untersuchung des Bundesamt für Strahlenschutz dokumentiert höchst bedenkliche Zahlen, für die β-Ortsdosimetrie, die die zulässige Jahresdosis um ein Vielfaches überschreiten können.
Die Einführung von sogenannten Thermolumineszensdetektoren, getragen als Ringdosimeter an den Grundgelenken der Zeigefinger, sollen realistische Expositionswerte aufzeichnen und somit eine Kontrolle der Dosis ermöglichen. Diese TLD’s sind mit der Markierung „RSO“ gekennzeichnet und werden nur bei der Arbeit mit den radioaktiven Substanzen getragen. Die monatliche Auswertung dokumentiert die Strahlenexposition der beteiligten Personen.
In verschiedenen Studien wurden Methoden zur Minimierung der Strahlenexposition getestet. Sie führten zu dem Ergebnis, dass die Abschirmung mit Acrylglas, die Abstandshaltung durch langschenklige Zangen sowie das Tragen von Nitril-Handschuhen am effektivsten zu einer Verringerung der Expositionswerte beitragen.
Ziel dieser retrospektiven Auswertung von Daten aus drei Jahren war es, die Effektivität der an der Klinik und Poliklinik für Nuklearmedizin in Würzburg praktizierten Strahlenschutzmaßnahmen zu untersuchen.
Über einen Zeitraum von drei Jahren wurden 547 Gelenke in 368 Patienten mit 52.421 MBq, der drei Radionuklide 169Er, 186Re und 90Y behandelt. Die Oberflächenpersonendosis Hp(0,07) wurde mittels Fingerringdosimeter aufgezeichnet.
Die acht an der Radiosynoviorthese beteiligten Personen erhielten eine kumulative Hautdosis Hp(0,07) von 498 mSv. Die kumulative Dosis pro Aktivität betrug somit weniger als 10 mSv/Bq. Sie lag pro Arzt bei 1,1 μSv/MBq und pro MTA bei bis zu 4,5 μSv/MBq.
Die akkumulierte Hautdosis Hp (0,07) während der Radiosynoviorthese war somit weitaus geringer im Vergleich zu den gesetzlichen Vorgaben und den zur Verfügung stehenden publizierten Daten.
Einleitung: Die linksventrikuläre diastolische Dysfunktion (LVDD) ist bei Diabetikern noch vor Entwicklung einer klinisch apparenten Herzinsuffizienz eines der ersten Anzeichen einer kardialen Beteiligung. Daher soll in dieser Studie untersucht werden, ob die LVDD mit ECG-gated F-18-FDG PET in einem Diabetes-Rattenmodell dargestellt werden kann.
Methodik: Es wurden F-18-FDG PET Scans in einem Typ-2-Diabetes Rattenmodell (ZDF fa/fa, n=6) und in ZL Kontrollen (n=6) vorgenommen (Alter, jeweils 13 Wochen). Unter Hyperinsulinemic-Euglycemic Clamp-Technik wurden 37 MBq 18F-FDG über die Schwanzvene appliziert. 15-35 Minuten nach Tracergabe wurden mittels eines Kleintier-PET-Scanners sowie unter EKG-Ableitung PET Scans angefertigt (16 frames/cardiac cycle). Die linksventrikuläre Ejektionsfraktion (EF) und die Peak Füllrate (PFR) wurden mittels einer geeigneten Software (Heart Function View) gemessen, wobei die Software an die Größe des Rattenherzes angepasst wurde.
Ergebnisse: Im Alter von 13 Wochen entwickeln ZDF Diabetes-Ratten eine im Vergleich zu Kontrolltieren eine signifikante myokardiale Hypertrophie, bestätigt durch post-mortem Analyse des Herzgewichtes (994±78mg vs. 871±44mg in ZDF Diabetes-Ratten vs. ZL Kontrollen, p<0.01). ECG-gated PET zeigte eine signifikante Abnahme der LV diastolischen PFR (10.4±0.5 vs. 11.8±0.4 EDV/sec in ZDF Diabetes-Ratten vs. ZL Kontrollen, p<0.001), jedoch zeigte sich kein signifikanter Unterschied zwischen LVEF und der Herzfrequenz in den untersuchten ZDF Diabetes-Ratten und Kontrollen (LVEF: 60.0±4.5 vs. 63.7±4.1%, n.s. und HR: 305±25 vs. 323±24 bpm, n.s.).
Schlussfolgerung: Im Diabetes-Ratten-Modell kann unter Verwendung eines ECG-gated FDG-PET Protokolls die diastolische Dysfunktion als Parameter der frühen diabetischen Kardiomyopathie nachgewiesen werden.
Die molekularen Parameter PSMA-TV und TL-PSMA im 68Ga-PSMA PET/CT leiten sich ab von MTV und TLG im FDG PET/CT. Mit der vorliegenden Arbeit wurden die Grenzen neuer Autosegmentierungsprogramme durch eine maximale Belastung mit großen Tumorvolumina von Patienten unter taxanbasierter Chemotherapie ausgelotet. Die Programme Syngo.via und FIJI kamen zu vergleichbaren Ergebnissen. Patienten mit einem Gleason Score von 8-10 zeigten unter Therapie eine signifikante Zunahme des PSMA-TV und TL-PSMA im Gegensatz zu Patienten mit Gleason Score 6-7b. Ein hoher PSA-Wert korrelierte zu allen Zeitpunkten signifikant mit einem hohen PSMA-TV und TL-PSMA, ebenso korrelierte ein steigender PSA-Wert signifikant mit steigenden Werten in PSMA-TV und TL-PSMA. Patienten mit einem biochemischen Progress und einem Progress nach modifiziertem PERCIST zeigten vor Therapie ein signifikant höheres PSMA-TV und TL-PSMA als Patienten ohne Progress und unter Therapie eine signifikante Zunahme des PSMA-TV und TL-PSMA im Vergleich zu Patienten ohne Progress. Eine Einteilung des Therapieansprechens aller Patienten in CR, PR, SD und PD nach PSMA-TV, TL-PSMA, PSA-Wert und modifiziertem PERCIST stimmte nicht in allen Patienten überein. Ein signifikant kürzeres Gesamtüberleben zeigten lediglich Patienten mit einem nach dem PSA-Wert definiertem Progress. Im praktischen Vergleich der beiden Programme benötigte Syngo.via für eine komplette Segmentierung signifikant mehr Zeit als FIJI, vor allem da der Wechsel von VOI zu VOI signifikant länger dauerte. Unabhängig vom Autosegmentierungsprogramm dauerte eine komplette Segmentierung länger, je größer das PSMA-TV und das TL-PSMA war, je mehr VOIs das Programm automatisch setzte und je mehr VOIs manuell gelöscht und neu gesetzt wurden. In der Gesamtschau bieten PSMA-TV und TL-PSMA in Kombination mit den sich schnell weiterentwickelnden Autosegmentierungs-Programmen die Möglichkeit, auch sehr hohe Tumorlasten des PCas objektiv und vergleichbar zu beschreiben.
Purpose
The impact on patients’ health of radiopharmaceuticals in nuclear medicine diagnostics has not until now been evaluated systematically in a European context. Therefore, as part of the EU-funded Project PEDDOSE.NET (www.peddose.net), we review and summarize the current knowledge on biokinetics and dosimetry of commonly used diagnostic radiopharmaceuticals.
Methods
A detailed literature search on published biokinetic and dosimetric data was performed mostly via PubMed (www.ncbi.nlm.nih.gov/pubmed). In principle the criteria for inclusion of data followed the EANM Dosimetry Committee guidance document on good clinical reporting.
Results
Data on dosimetry and biokinetics can be difficult to find, are scattered in various journals and, especially in paediatric nuclear medicine, are very scarce. The data collection and calculation methods vary with respect to the time-points, bladder voiding, dose assessment after the last data point and the way the effective dose was calculated. In many studies the number of subjects included for obtaining biokinetic and dosimetry data was fewer than ten, and some of the biokinetic data were acquired more than 20 years ago.
Conclusion
It would be of interest to generate new data on biokinetics and dosimetry in diagnostic nuclear medicine using state-of-the-art equipment and more uniform dosimetry protocols. For easier public access to dosimetry data for diagnostic radiopharmaceuticals, a database containing these data should be created and maintained.
Background:
Renal scans are among the most frequent exams performed on infants and toddlers. Due to the young age, this patient group can be classified as a high-risk group with a higher probability for developing stochastic radiation effects compared to adults. As there are only limited data on biokinetics and dosimetry in this patient group, the aim of this study was to reassess the dosimetry and the associated radiation risk for infants undergoing \(^{99m}\)Tc-MAG3 renal scans based on a retrospective analysis of existing patient data. Consecutive data were collected from 20 patients younger than 20 months (14 males; 6 females) with normal renal function undergoing \(^{99m}\)Tc-MAG3 scans. To estimate the patient-specific organ activity, a retrospective calibration was performed based on a set of two 3D-printed infant kidneys filled with known activities. Both phantoms were scanned at different positions along the anteroposterior axis inside a water phantom, providing depth- and size-dependent attenuation correction factors for planar imaging. Time-activity curves were determined by drawing kidney, bladder, and whole-body regions-of-interest for each patient, and subsequently applying the calibration factor for conversion of counts to activity. Patient-specific time-integrated activity coefficients were obtained by integrating the organ-specific time-activity curves. Absorbed and effective dose coefficients for each patient were assessed with OLINDA/EXM for the provided newborn and 1-year-old model. The risk estimation was performed individually for each of the 20 patients with the NCI Radiation Risk Assessment Tool.
Results:
The mean age of the patients was 7.0 ± 4.5 months, with a weight between 5 and 12 kg and a body size between 60 and 89 cm. The injected activities ranged from 12 to 24 MBq of \(^{99m}\)Tc-MAG3. The patients' organ-specific mean absorbed dose coefficients were 0.04 ± 0.03 mGy/MBq for the kidneys and 0.27 ± 0.24 mGy/MBq for the bladder. The mean effective dose coefficient was 0.02 ± 0.02 mSv/MBq. Based on the dosimetry results, an evaluation of the excess lifetime risk for the development of radiation-induced cancer showed that the group of newborns has a risk of 16.8 per 100,000 persons, which is about 12% higher in comparison with the 1-year-old group with 14.7 per 100,000 persons (all values are given as mean plus/minus one standard deviation except otherwise specified).
Conclusion:
In this study, we retrospectively derived new data on biokinetics and dosimetry for infants with normal kidney function after undergoing renal scans with \(^{99m}\)Tc-MAG3. In addition, we analyzed the associated age- and gender-specific excess lifetime risk due to ionizing radiation. The radiation-associated stochastic risk increases with the organ doses, taking age- and gender-specific influences into account. Overall, the lifetime radiation risk associated with the \(^{99m}\)Tc-MAG3 scans is very low in comparison to the general population risk for developing cancer.
Pathophysiological understanding of gait and balance disorders in Parkinson’s disease is insufficient and late recognition of fall risk limits efficacious followup to prevent or delay falls. We show a distinctive reduction of glucose metabolism in the left posterior parietal cortex, with increased metabolic activity in the cerebellum, in parkinsonian patients 6–8 months before their first fall episode. Falls in Parkinson’s disease may arise from altered cortical processing of body spatial orientation, possibly predicted by abnormal cortical metabolism.
Published studies on the risk of radiation-induced second primary malignancy (SPM) after radioiodine treatment (RAI) of differentiated thyroid cancer (DTC) refer mainly to patients treated as middle-aged or older adults and are not easily generalizable to those treated at a younger age. Here we review available literature on the risk of breast cancer as an SPM after RAI of DTC with a focus on females undergoing such treatment in childhood, adolescence, or young adulthood. Additionally, we report the results of a preliminary international survey of patient registries from academic tertiary referral centers specializing in pediatric DTC. The survey sought to evaluate the availability of sufficient patient data for a potential international multicenter observational case–control study of females with DTC given RAI at an early age. Our literature review identified a bi-directional association of DTC and breast cancer. The general breast cancer risk in adult DTC survivors is low, ~2%, slightly higher in females than in males, but presumably lower, not higher, in those diagnosed as children or adolescents than in those diagnosed at older ages. RAI presumably does not substantially influence breast cancer risk after DTC. However, data from patients given RAI at young ages are sparse and insufficient to make definitive conclusions regarding age dependence of the risk of breast cancer as a SPM after RAI of DTC. The preliminary analysis of data from 10 thyroid cancer registries worldwide, including altogether 6,449 patients given RAI for DTC and 1,116 controls, i.e., patients not given RAI, did not show a significant increase of breast cancer incidence after RAI. However, the numbers of cases and controls were insufficient to draw statistically reliable conclusions, and the proportion of those receiving RAI at the earliest ages was too low.In conclusion, a potential international multicenter study of female patients undergoing RAI of DTC as children, adolescents, or young adults, with a sufficient sample size, is feasible. However, breast cancer screening of a larger cohort of DTC patients is not unproblematic for ethical reasons, due to the likely, at most slightly, increased risk of breast cancer post-RAI and the expected ~10% false-positivity rate which potentially produced substantial “misdiagnosis.”
DNA double strand break (DSB) formation induced by ionizing radiation exposure is indicated by the DSB biomarkers \(\gamma\)-H2AX and 53BP1. Knowledge about DSB foci formation in-vitro after internal irradiation of whole blood samples with radionuclides in solution will help us to gain detailed insights about dose-response relationships in patients after molecular radiotherapy (MRT). Therefore, we studied the induction of radiation-induced co-localizing \(\gamma\)-H2AX and 53BP1 foci as surrogate markers for DSBs in-vitro, and correlated the obtained foci per cell values with the in-vitro absorbed doses to the blood for the two most frequently used radionuclides in MRT (I-131 and Lu-177). This approach led to an in-vitro calibration curve. Overall, 55 blood samples of three healthy volunteers were analyzed. For each experiment several vials containing a mixture of whole blood and radioactive solutions with different concentrations of isotonic NaCl-diluted radionuclides with known activities were prepared. Leukocytes were recovered by density centrifugation after incubation and constant blending for 1 h at 37°C. After ethanol fixation they were subjected to two-color immunofluorescence staining and the average frequencies of the co-localizing \(\gamma\)-H2AX and 53BP1 foci/nucleus were determined using a fluorescence microscope equipped with a red/green double band pass filter. The exact activity was determined in parallel in each blood sample by calibrated germanium detector measurements. The absorbed dose rates to the blood per nuclear disintegrations occurring in 1 ml of blood were calculated for both isotopes by a Monte Carlo simulation. The measured blood doses in our samples ranged from 6 to 95 mGy. A linear relationship was found between the number of DSB-marking foci/nucleus and the absorbed dose to the blood for both radionuclides studied. There were only minor nuclide-specific intra-and inter-subject deviations.
Molecular imaging of rats is of great importance for basic and translational research. As a powerful tool in nuclear medicine, SPECT can be used to visualize specific functional processes in the body, such as myocardial perfusion or bone metabolism. Typical applications in laboratory animals are imaging diagnostics or the development of new tracers for clinical use. Innovations have enabled resolutions of up to a quarter of a millimeter with acceptable sensitivity. These advances have recently led to significantly more interest in SPECT both clinically and preclinically.
The objective of this thesis was to evaluate the performance of the new U-SPECT5/CT E-Class by MILabs with a dedicated ultra-high resolution multi-pinhole collimator for rats and its potential for in vivo imaging of rats. The unique features of the U-SPECT are the large stationary detectors and the new iterative reconstruction algorithm. In addition, compared to the conventional system, the "E-Class" uses only two detectors instead of three.
First, the sensitivity, maximum resolution, and uniformity were determined as performance parameters. Thereafter, CNRs for different activity levels comparable to those of typical in vivo activities were examined. Finally, two example protocols were carried out for imaging with 99mTc-MIBI and 99mTc-HMDP in healthy rats to evaluate the in vivo capabilities. For this purpose, CNR calculations and an image quality assessment were performed. The focus was on image quality as a function of scan time and post-reconstruction filter across a wide range of realistically achievable in vivo conditions.
Performance was reasonable compared to other systems in the literature, with a sensitivity of 567 cps/MBq, a maximum resolution of 1.20 mm, and a uniformity of 55.5%. At the lower activities, resolution in phantom studies decreased to ≥1.80 mm while maintaining good image quality. High-quality bone and myocardial perfusion SPECTs were obtained in rats with a resolution of ≥1.80 mm and ≥2.20 mm, respectively. Although limited sensitivity remains a weakness of SPECT, the U-SPECT5/CT E-Class with the UHR-RM collimator can achieve in vivo results of the highest standard despite the missing third detector. Currently, it is one of the best options for high-resolution radionuclide imaging in rats.
We aimed to investigate the image quality of the U-SPECT5/CT E-Class a micro single-photon emission computed tomography (SPECT) system with two large stationary detectors for visualization of rat hearts and bones using clinically available \(^{99m}\)Tc-labelled tracers. Sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR) of the small-animal SPECT scanner were investigated in phantom studies using an ultra-high-resolution rat and mouse multi-pinhole collimator (UHR-RM). Point source, hot-rod, and uniform phantoms with \(^{99m}\)Tc-solution were scanned for high-count performance assessment and count levels equal to animal scans, respectively. Reconstruction was performed using the similarity-regulated ordered-subsets expectation maximization (SROSEM) algorithm with Gaussian smoothing. Rats were injected with similar to 100 MBq [\(^{99m}\)TcTc-MIBI or similar to 150 MBq [\(^{99m}\)Tc]Tc-HMDP and received multi-frame micro-SPECT imaging after tracer distribution. Animal scans were reconstructed for three different acquisition times and post-processed with different sized Gaussian filters. Following reconstruction, CNR was calculated and image quality evaluated by three independent readers on a five-point scale from 1="very poor" to 5="very good". Point source sensitivity was 567 cps/MBq and radioactive rods as small as 1.2 mm were resolved with the UHR-RM collimator. Collimator-dependent uniformity was 55.5%. Phantom CNR improved with increasing rod size, filter size and activity concentration. Left ventricle and bone structures were successfully visualized in rat experiments. Image quality was strongly affected by the extent of post-filtering, whereas scan time did not have substantial influence on visual assessment. Good image quality was achieved for resolution range greater than 1.8 mm in bone and 2.8 mm in heart. The recently introduced small animal SPECT system with two stationary detectors and UHR-RM collimator is capable to provide excellent image quality in heart and bone scans in a rat using standardized reconstruction parameters and appropriate post-filtering. However, there are still challenges in achieving maximum system resolution in the sub-millimeter range with in vivo settings under limited injection dose and acquisition time.