Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik)
Refine
Has Fulltext
- yes (21)
Is part of the Bibliography
- yes (21)
Year of publication
- 2022 (21) (remove)
Document Type
- Journal article (20)
- Other (1)
Keywords
- MRI (2)
- endovascular (2)
- radiomics (2)
- 2D-perfusion angiography (1)
- 3D printing (1)
- AMADEUS (1)
- CT (1)
- Cisplatin (1)
- DSA (1)
- Diagnose (1)
Institute
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (21)
- Deutsches Zentrum für Herzinsuffizienz (DZHI) (3)
- Lehrstuhl für Orthopädie (3)
- Klinik und Poliklinik für Unfall-, Hand-, Plastische und Wiederherstellungschirurgie (Chirurgische Klinik II) (2)
- Theodor-Boveri-Institut für Biowissenschaften (2)
- Urologische Klinik und Poliklinik (2)
- Institut für Anatomie und Zellbiologie (1)
- Institut für Virologie und Immunbiologie (1)
- Kinderklinik und Poliklinik (1)
- Klinik und Poliklinik für Anästhesiologie (ab 2004) (1)
Sonstige beteiligte Institutionen
Die Riesenzellarteriitis (RZA) ist in der Altersgruppe der über 50-Jährigen die häufigste idiopathische systemische Vaskulitis. Die Erkrankung bedarf einer zeitnahen Diagnostik und Therapie, um schwere Komplikationen wie eine Erblindung oder einen Schlaganfall zu vermeiden. Die Rezidivneigung erfordert eine mehrjährige, zum Teil lebenslange Glukokortikoid(GC)-Therapie, was das Risiko GC-induzierter Langzeitnebenwirkungen erhöht. Daher wird bei der Mehrzahl der Patienten eine additive GC-einsparende Therapie empfohlen. Hierzu steht der Anti-IL-6-Rezeptor-Antikörper Tocilizumab in subkutaner Applikation als zugelassene Substanz zur Verfügung, alternativ kann Methotrexat (MTX) eingesetzt werden (off-label).
Purpose
To evaluate the technical and clinical outcome of Sinus-XL stent placement in patients with malignant obstruction syndrome of the inferior vena cava.
Methods
Between October 2010 and January 2021, 21 patients with different malignant primary disease causing inferior vena cava obstruction were treated with Sinus-XL stent implantation. Procedural data, technical and clinical outcome parameters were retrospectively analyzed.
Results
Technical success was 100%. Analysis of available manometry data revealed a significant reduction of the mean translesional pressure gradient following the procedure (p = 0.008). Reintervention rate was 4.8% (1/21). The available follow-up imaging studies showed primary and primary-assisted stent patency rates of 93% (13/14) and 100% (14/14), respectively. Major complications did not occur. The clinical success regarding lower extremity edema was 82.4% (14/17) for the first and 85.7% (18/21) for the last follow-up. Longer lengths of IVC obstruction were associated with reduced clinical improvement after the procedure (p = 0.025). Improvement of intraprocedural manometry results and lower extremity edema revealed only minor correlation. Ascites and anasarca were not significantly positively affected by the procedure.
Conclusion
Sinus-XL stent placement in patients with malignant inferior vena cava obstruction showed high technical success and low complication rates. Regarding the clinical outcome, significant symptom improvement could be achieved in lower extremity edema, whereas ascites and anasarca lacked satisfying symptom relief. Based on our results, this procedure should be considered as a suitable therapy in a palliative care setting for patients with advanced malignant disease.
Background
Children with different underlying malignant diseases require long-term central venous access. As for port systems in a pectoral position, peripherally implanted port systems in the forearm revealed high levels of technical and clinical success in adult cohorts.
Objective
To investigate the technical and clinical outcomes of percutaneous central venous port implantation in the forearm in adolescents.
Materials and methods
Between April 2010 and August 2020, 32 children ages 9 to 17 years with underlying malignancy received 35 totally implantable venous access ports (TIVAPs) in the forearm. All venous port systems were peripherally inserted under ultrasound guidance. Correct catheter placement was controlled by fluoroscopy. As primary endpoints, the technical success, rate of complications and catheter maintenance were analyzed. Secondary endpoints were the side of implantation, vein of catheter access, laboratory results on the day of the procedure, procedural radiation exposure, amount of contrast agent and reasons for port device removal.
Results
Percutaneous TIVAP placement under sonographic guidance was technically successful in 34 of 35 procedures (97.1%). Procedure-related complications did not occur. During the follow-up, 13,684 catheter days were analyzed, revealing 11 complications (0.8 per 1,000 catheter-duration days), Of these 11 complications, 7 were major and 10 occurred late. In seven cases, the port device had to be removed; removal-related complications did not occur.
Conclusion
Peripheral TIVAP placement in the forearms of children is a feasible, effective and safe technique with good midterm outcome. As results are comparable with standard access routes, this technique may be offered as an alternative when intermittent venous access is required.
Objective
Multipartite epicondyles may mimic fractures in the setting of pediatric elbow trauma. This study examines the prevalence of multipartite epicondyles during skeletal development and their association with pediatric elbow fractures.
Materials and methods
In this retrospective analysis, 4282 elbow radiographs of 1265 elbows of 1210 patients aged 0–17 years were reviewed. The radiographs were analyzed by two radiologists in consensus reading, and the number of visible portions of the medial and lateral epicondyles was noted. For elbows in which epicondylar ossification was not yet visible, the epicondyles were already fused with the humerus or could not be sufficiently evaluated due to projection issues or because osteosynthesis material was excluded. In total, 187 elbows were included for the lateral and 715 for the medial epicondyle analyses.
Results
No multipartite medial epicondyles were found in patients without history of elbow fracture, whereas 9% of these patients had multipartite lateral epicondyles (p < 0.01). Current or previous elbow fractures increased the prevalence of multipartite epicondyles, with significant lateral predominance (medial epicondyle + 9% vs. lateral + 24%, p < 0.0001). Including all patients regardless of a history of elbow fracture, multipartite medial epicondyles were observed in 3% and multipartite lateral epicondyles in 18% (p < 0.0001). There was no gender difference in the prevalence of multipartition of either epicondyle, regardless of a trauma history.
Conclusion
Multipartite medial epicondyles occur in patients with current or previous elbow fractures only, whereas multipartite lateral epicondyles may be constitutional. Elbow fractures increase the prevalence of multipartite epicondyles on both sides, with significant lateral predominance.
Key Points
• Multipartite medial epicondyles should be considered of traumatic origin.
• Multipartite lateral epicondyles may be constitutional.
• Elbow fractures increase the prevalence of multipartite epicondyles on both sides with lateral predominance.
(1) Background: To evaluate radiomics features as well as a combined model with clinical parameters for predicting overall survival in patients with bladder cancer (BCa). (2) Methods: This retrospective study included 301 BCa patients who received radical cystectomy (RC) and pelvic lymphadenectomy. Radiomics features were extracted from the regions of the primary tumor and pelvic lymph nodes as well as the peritumoral regions in preoperative CT scans. Cross-validation was performed in the training cohort, and a Cox regression model with an elastic net penalty was trained using radiomics features and clinical parameters. The models were evaluated with the time-dependent area under the ROC curve (AUC), Brier score and calibration curves. (3) Results: The median follow-up time was 56 months (95% CI: 48–74 months). In the follow-up period from 1 to 7 years after RC, radiomics models achieved comparable predictive performance to validated clinical parameters with an integrated AUC of 0.771 (95% CI: 0.657–0.869) compared to an integrated AUC of 0.761 (95% CI: 0.617–0.874) for the prediction of overall survival (p = 0.98). A combined clinical and radiomics model stratified patients into high-risk and low-risk groups with significantly different overall survival (p < 0.001). (4) Conclusions: Radiomics features based on preoperative CT scans have prognostic value in predicting overall survival before RC. Therefore, radiomics may guide early clinical decision-making.
Background
To investigate the effects of B\(_1\)-shimming and radiofrequency (RF) parallel transmission (pTX) on the visualization and quantification of the degree of stenosis in a coronary artery phantom using 7 Tesla (7 T) magnetic resonance imaging (MRI).
Methods
Stenosis phantoms with different grades of stenosis (0%, 20%, 40%, 60%, 80%, and 100%; 5 mm inner vessel diameter) were produced using 3D printing (clear resin). Phantoms were imaged with four different concentrations of diluted Gd-DOTA representing established arterial concentrations after intravenous injection in humans. Samples were centrally positioned in a thorax phantom of 30 cm diameter filled with a custom-made liquid featuring dielectric properties of muscle tissue. MRI was performed on a 7 T whole-body system. 2D-gradient-echo sequences were acquired with an 8-channel transmit 16-channel receive (8 Tx / 16 Rx) cardiac array prototype coil with and without pTX mode. Measurements were compared to those obtained with identical scan parameters using a commercially available 1 Tx / 16 Rx single transmit coil (sTX). To assess reproducibility, measurements (n = 15) were repeated at different horizontal angles with respect to the B0-field.
Results
B\(_1\)-shimming and pTX markedly improved flip angle homogeneity across the thorax phantom yielding a distinctly increased signal-to-noise ratio (SNR) averaged over a whole slice relative to non-manipulated RF fields. Images without B\(_1\)-shimming showed shading artifacts due to local B\(_1\)\(^+\)-field inhomogeneities, which hampered stenosis quantification in severe cases. In contrast, B\(_1\)-shimming and pTX provided superior image homogeneity. Compared with a conventional sTX coil higher grade stenoses (60% and 80%) were graded significantly (p<0.01) more precise. Mild to moderate grade stenoses did not show significant differences. Overall, SNR was distinctly higher with B\(_1\)-shimming and pTX than with the conventional sTX coil (inside the stenosis phantoms 14%, outside the phantoms 32%). Both full and half concentration (10.2 mM and 5.1 mM) of a conventional Gd-DOTA dose for humans were equally suitable for stenosis evaluation in this phantom study.
Conclusions
B\(_1\)-shimming and pTX at 7 T can distinctly improve image homogeneity and therefore provide considerably more accurate MR image analysis, which is beneficial for imaging of small vessel structures.
Background
Endovascular revascularization has become the first-line treatment of chronic mesenteric ischemia (CMI). The qualitative visual analysis of digital subtraction angiography (DSA) is dependent on observer experience and prone to interpretation errors. We evaluate the feasibility of 2D-Perfusion Angiography (2D-PA) for objective, quantitative treatment response assessment in CMI.
Methods
49 revascularizations in 39 patients with imaging based evidence of mesenteric vascular occlusive disease and clinical signs of CMI were included in this retrospective study. To assess perfusion changes by 2D-PA, DSA-series were post-processed using a dedicated, commercially available software. Regions of interest (ROI) were placed in the pre- and post-stenotic artery segment. In aorto-ostial disease, the inflow ROI was positioned at the mesenteric artery orifice. The ratios outflow to inflow ROI for peak density (PD), time to peak and area-under-the-curve (AUC) were computed and compared pre- and post-interventionally. We graded motion artifacts by means of a four-point scale. Feasibility of 2D-PA and changes of flow parameters were evaluated.
Results
Motion artifacts due to a mobile vessel location beneath the diaphragm or within the mesenteric root, branch vessel superimposition and inadequate contrast enhancement at the inflow ROI during manually conducted DSA-series via selective catheters owing to steep vessel angulation, necessitated exclusion of 26 measurements from quantitative flow evaluation. The feasibility rate was 47%. In 23 technically feasible assessments, PD\(_{outflow}\)/PD\(_{inflow}\) increased by 65% (p < 0.001) and AUC\(_{outflow}\)/AUC\(_{inflow}\) increased by 85% (p < 0.001). The time to peak density values in the outflow ROI accelerated only minimally without reaching statistical significance. Age, BMI, target vessel (celiac trunk, SMA or IMA), stenosis location (ostial or truncal), calcification severity, plaque composition or the presence of a complex stenosis did not reach statistical significance in their distribution among the feasible and non-feasible group (p > 0.05).
Conclusions
Compared to other vascular territories and indications, the feasibility of 2D-PA in mesenteric revascularization for CMI was limited. Unfavorable anatomic conditions contributed to a high rate of inconclusive 2D-PA results.
Acute ischemic cardiac injury predisposes one to cognitive impairment, dementia, and depression. Pathophysiologically, recent positron emission tomography data suggest astroglial activation after experimental myocardial infarction (MI). We analyzed peripheral surrogate markers of glial (and neuronal) damage serially within 12 months after the first ST-elevation MI (STEMI). Serum levels of glial fibrillary acidic protein (GFAP) and neurofilament light chain (NfL) were quantified using ultra-sensitive molecular immunoassays. Sufficient biomaterial was available from 45 STEMI patients (aged 28 to 78 years, median 56 years, 11% female). The median (quartiles) of GFAP was 63.8 (47.0, 89.9) pg/mL and of NfL 10.6 (7.2, 14.8) pg/mL at study entry 0–4 days after STEMI. GFAP after STEMI increased in the first 3 months, with a median change of +7.8 (0.4, 19.4) pg/mL (p = 0.007). It remained elevated without further relevant increases after 6 months (+11.7 (0.6, 23.5) pg/mL; p = 0.015), and 12 months (+10.3 (1.5, 22.7) pg/mL; p = 0.010) compared to the baseline. Larger relative infarction size was associated with a higher increase in GFAP (ρ = 0.41; p = 0.009). In contrast, NfL remained unaltered in the course of one year. Our findings support the idea of central nervous system involvement after MI, with GFAP as a potential peripheral biomarker of chronic glial damage as one pathophysiologic pathway.
Purpose
Machine learning based on radiomics features has seen huge success in a variety of clinical applications. However, the need for standardization and reproducibility has been increasingly recognized as a necessary step for future clinical translation. We developed a novel, intuitive open-source framework to facilitate all data analysis steps of a radiomics workflow in an easy and reproducible manner and evaluated it by reproducing classification results in eight available open-source datasets from different clinical entities.
Methods
The framework performs image preprocessing, feature extraction, feature selection, modeling, and model evaluation, and can automatically choose the optimal parameters for a given task. All analysis steps can be reproduced with a web application, which offers an interactive user interface and does not require programming skills. We evaluated our method in seven different clinical applications using eight public datasets: six datasets from the recently published WORC database, and two prostate MRI datasets—Prostate MRI and Ultrasound With Pathology and Coordinates of Tracked Biopsy (Prostate-UCLA) and PROSTATEx.
Results
In the analyzed datasets, AutoRadiomics successfully created and optimized models using radiomics features. For WORC datasets, we achieved AUCs ranging from 0.56 for lung melanoma metastases detection to 0.93 for liposarcoma detection and thereby managed to replicate the previously reported results. No significant overfitting between training and test sets was observed. For the prostate cancer detection task, results were better in the PROSTATEx dataset (AUC = 0.73 for prostate and 0.72 for lesion mask) than in the Prostate-UCLA dataset (AUC 0.61 for prostate and 0.65 for lesion mask), with external validation results varying from AUC = 0.51 to AUC = 0.77.
Conclusion
AutoRadiomics is a robust tool for radiomic studies, which can be used as a comprehensive solution, one of the analysis steps, or an exploratory tool. Its wide applicability was confirmed by the results obtained in the diverse analyzed datasets. The framework, as well as code for this analysis, are publicly available under https://github.com/pwoznicki/AutoRadiomics.