Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik)
Refine
Has Fulltext
- yes (25)
Is part of the Bibliography
- yes (25)
Year of publication
- 2023 (25) (remove)
Document Type
- Journal article (19)
- Doctoral Thesis (6)
Keywords
- magnetic resonance imaging (3)
- CT angiography (2)
- cartilage (2)
- computed tomography (2)
- translational research (2)
- AMADEUS (1)
- Bildgebendes Verfahren (1)
- Echtzeit (1)
- Gallengangsstenose (1)
- Gefäßverschluss (1)
Institute
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (25)
- Institut für Anatomie und Zellbiologie (8)
- Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I) (3)
- Institut für diagnostische und interventionelle Neuroradiologie (ehem. Abteilung für Neuroradiologie) (2)
- Klinik und Poliklinik für Unfall-, Hand-, Plastische und Wiederherstellungschirurgie (Chirurgische Klinik II) (2)
- Lehrstuhl für Orthopädie (2)
- Medizinische Klinik und Poliklinik II (2)
- Abteilung für Funktionswerkstoffe der Medizin und der Zahnheilkunde (1)
- Augenklinik und Poliklinik (1)
- Deutsches Zentrum für Herzinsuffizienz (DZHI) (1)
Die interventionelle Radiologie hat sich in den letzten Jahrzehnten zunehmend auf palliativmedizinische sowie onkologische Bereiche ausgeweitet und kann durch minimal-invasive Therapieoptionen gerade in vulnerablen Patientenkollektiven attraktive Behandlungsmöglichkeiten zur Verfügung stellen. Die tumorbedingte untere Einflussstauung ist ein seltenes Krankheitsbild und stellt eine schwere symptomatische Komplikation einer malignen Grunderkrankung dar. Dabei kommt es im Rahmen dieser Grunderkrankung durch die Primärtumormasse oder Metastasen zu extrinsischer Kompression der Vena cava inferior (VCI), Gefäßinvasion oder Thrombusbildung.
Ziel der Dissertationsarbeit ist es, den technischen und klinischen Erfolg der Sinus-XL ® Stentimplantation in die Vena cava inferior bei einer tumorbedingten unteren Einflussstauung zu untersuchen. Als technischer Erfolg wurde dabei die problemlose Stentimplantation mit anschließender Aufhebung der VCI-Stenose/Okklusion und Revaskularisation der VCI definiert. Bezüglich des klinischen Erfolges wurde der Frage nachgegangen, inwieweit die Stentimplantation die typischen Symptome einer unteren Einflussstauung (Ödeme der unteren Extremität, Aszites und Anasarka) lindern und bestenfalls eliminieren kann. In der vorliegenden Arbeit sind dazu retrospektiv die Daten von insgesamt 21 Patienten (11 Frauen, 10 Männer) mit einem medianen Alter von 61 Jahren (19-92 Jahre), die zwischen Oktober 2010 und Januar 2021 aufgrund einer tumorbedingten unteren Einflussstauung mit einem Sinus-XL ® Stent endovaskulär versorgt wurden, ausgewertet worden. Zur Quantifizierung der klinischen Symptomatik wurde für das jeweilige Symptom ein Scoring-System entwickelt bzw. modifiziert.
Der technische Erfolg belief sich auf 100% (21/21). Postinterventionell konnte zudem eine signifikante Reduktion des transstenotischen Druckgradienten (p = 0,008) und eine signifikante Aufweitung des Stenosendiameters (p < 0,001) erreicht werden. Die primäre und primär-assistierte Stentoffenheit betrug 92,9 % (13/14) und 100% (14/14), die anatomische Stentoffenheit (< 50% Restenose) belief sich auf 53,3 % (8/15). Die Reinterventionsrate lag bei 4,8 % (1/21). Schwerwiegende Komplikationen traten nicht auf. Der klinische Erfolg bezüglich der Ödeme der unteren Extremität belief sich auf 82,4 % (14/17), 93,8 % (15/16) sowie auf 85,7 % (18/21) und zeigte in allen betrachteten Zeitintervallen eine signifikante Scorewertreduktion (p < 0,001). Das klinische Outcome bezüglich der Ödeme war bei kürzeren Stenosen/Obstruktionen signifikant besser (p = 0,025). Bezüglich einer intrahepatischen Segmentbeteiligung, der transstenotischen Druckgradienten, der absoluten Gradientenreduktion sowie der Überlebenszeit nach der Intervention zeigten sich hingegen keine als klinisch relevant einzustufende Ergebnisse. Ein eindeutiger Effekt der Intervention auf die Symptome Anasarka und Aszites konnte nicht nachgewiesen werden. Diesbezüglich zeigten sich klinische Erfolgsraten von 42,9 % (6/14) und 5,3 % (1/19). Im postinterventionellen Verlauf konnten außerdem signifikante Reduktionen der präinterventionellen Harnstoffwerte sowie des Körpergewichtes der Patienten verzeichnet werden.
Zusammenfassend zeigt die vorliegende Arbeit, dass die Sinus-XL ® Stentimplantation geeignet ist, eine tumorbedingte Vena cava inferior-Stenose/Obstruktion aufzuheben und eine Revaskularisation der VCI zu erreichen. Die klinischen Symptome einer unteren Einflussstauung – insbesondere bezogen auf die Ödeme der unteren Extremität und mit Einschränkungen bezogen auf die Symptome Aszites und Anasarka – können ebenfalls durch die Stentimplantation gelindert und teilweise sogar langanhaltend eliminiert werden. Die Sinus-XL ® Stentimplantation sollte daher stets als Therapieoption bei tumorbedingten unteren Einflussstauungen in Erwägung gezogen werden. Nicht zuletzt stellt die Stentimplantation auch eine sichere und komplikationsarme Intervention dar. Weitere Studien, bestenfalls multizentrische Studien, sind jedoch notwendig, um die dargestellten Ergebnisse weiter zu untermauern.
Das Ziel der Studie bestand darin, die Durchführbarkeit, Effizienz und Sicherheit der perkutanen transluminalen Zangenbiopsie bei biliären Strikturen nach „Cross and push“ Technik am Universitätsklinikum Würzburg zu evaluieren.
Die Gewinnung der Zangenbiopsie bei den insgesamt 17 Patienten erfolgte an den baugleichen Angiographieeinheiten der interventionellen radiologischen Abteilung.
Die Schaffung des biliären Zugangsweges wurde per Feinnadelpunktion oder über einen bereits einliegenden Drainagekatheter durchgeführt. Nach Vordirigieren einer armierten Führungsschleuse bis unmittelbar vor die Stenose wurden die Gewebeproben mittels Biopsiezange entnommen. Auf diese Weise sollte ein Abknicken des Instrumentariums durch die fibrotische Beschaffenheit der Striktur vermieden und so die Gewebegewinnung erleichtert werden. Im Anschluss folgten die PTCD-Neuanlage bzw. der Katheterwechsel sowie die histologische Auswertung der Zangenbiopsie. Die Dokumentation umfasste den technischen Erfolg, die Biopsieanzahl sowie -größe, die Untersuchungs- und die Fluoroskopiezeit, das Dosisflächenprodukt, die Repräsentativität der Biopsien und die Komplikationsrate.
Die technische Erfolgsrate lag bei 100 %. Bei zehn Patienten und Patientinnen (58,8 %) wurde in der Zangenbiopsie ein Malignom bestätigt. Bei sieben Betroffenen (41,2 %) ergab die Zangenbiopsie einen benignen Befund, wobei dieser in zwei Fällen (11,8 %) falsch negativ war. Die Kriterien der Repräsentativität wurden bei elf Patienten und Patientinnen (64,7 %) erfüllt. Die mediane Biopsiezahl betrug 4 und die Biopsiegröße war 1 - 2 mm. Bei einer medianen Untersuchungszeit von 24 min bemaß sich die mediane Fluoroskopiezeit auf 7,6 min. Das mediane DAP für alle Interventionen betrug 2.593 μGym2. Zu einer Majorkomplikation kam es bei einer Patientin (5,9 %).
Bei der perkutanen transluminalen Zangenbiopsie nach „Cross and push“ Technik handelt es sich um ein effektives und sicheres Verfahren zur histologischen Beurteilung biliärer Strikturen mit einer moderaten Komplikationsrate. Die Anwendung sollte besonders bei proximalen Strikturen in Betracht gezogen werden, wenn die ERCP oder alternative Verfahren nicht erfolgreich waren und parallel eine Entlastung der Cholestase via PTCD intendiert oder bereits vorhanden ist. Zur weiteren Evaluation der Methode ist zukünftig die Betrachtung eines größeren Patientenkollektives nötig. Um das Verfahren mit Alternativmethoden vergleichen zu können, bedarf es randomisierter kontrollierter Studien.
Purpose
The reliable detection of tumor-infiltrated axillary lymph nodes for breast cancer [BC] patients plays a decisive role in further therapy. We aimed to find out whether cross-sectional imaging techniques could improve sensitivity for pretherapeutic axillary staging in nodal-positive BC patients compared to conventional imaging such as mammography and sonography.
Methods
Data for breast cancer patients with tumor-infiltrated axillary lymph nodes having received surgery between 2014 and 2020 were included in this study.
All examinations (sonography, mammography, computed tomography [CT] and magnetic resonance imaging [MRI]) were interpreted by board-certified specialists in radiology. The sensitivity of different imaging modalities was calculated, and binary logistic regression analyses were performed to detect variables influencing the detection of positive lymph nodes.
Results
All included 382 breast cancer patients had received conventional imaging, while 52.61% of the patients had received cross-sectional imaging.
The sensitivity of the combination of all imaging modalities was 68.89%. The combination of MRI and CT showed 63.83% and the combination of sonography and mammography showed 36.11% sensitivity.
Conclusion
We could demonstrate that cross-sectional imaging can improve the sensitivity of the detection of tumor-infiltrated axillary lymph nodes in breast cancer patients. Only the safe detection of these lymph nodes at the time of diagnosis enables the evaluation of the response to neoadjuvant therapy, thereby allowing access to prognosis and improving new post-neoadjuvant therapies.
Minimally invasive endovascular interventions have become an important tool for the treatment of cardiovascular diseases such as ischemic heart disease, peripheral artery disease, and stroke. X-ray fluoroscopy and digital subtraction angiography are used to precisely guide these procedures, but they are associated with radiation exposure for patients and clinical staff. Magnetic Particle Imaging (MPI) is an emerging imaging technology using time-varying magnetic fields combined with magnetic nanoparticle tracers for fast and highly sensitive imaging. In recent years, basic experiments have shown that MPI has great potential for cardiovascular applications. However, commercially available MPI scanners were too large and expensive and had a small field of view (FOV) designed for rodents, which limited further translational research. The first human-sized MPI scanner designed specifically for brain imaging showed promising results but had limitations in gradient strength, acquisition time and portability. Here, we present a portable interventional MPI (iMPI) system dedicated for real-time endovascular interventions free of ionizing radiation. It uses a novel field generator approach with a very large FOV and an application-oriented open design enabling hybrid approaches with conventional X-ray-based angiography. The feasibility of a real-time iMPI-guided percutaneous transluminal angioplasty (PTA) is shown in a realistic dynamic human-sized leg model.
Objective
Blindness is a feared complication of giant cell arteritis (GCA). However, the spectrum of pathologic orbital imaging findings on magnetic resonance imaging (MRI) in GCA is not well understood. In this study, we assess inflammatory changes of intraorbital structures on black blood MRI (BB-MRI) in patients with GCA compared to age-matched controls.
Methods
In this multicenter case-control study, 106 subjects underwent BB-MRI. Fifty-six patients with clinically or histologically diagnosed GCA and 50 age-matched controls without clinical or laboratory evidence of vasculitis were included. All individuals were imaged on a 3-T MR scanner with a post-contrast compressed-sensing (CS) T1-weighted sampling perfection with application-optimized contrasts using different flip angle evolution (SPACE) BB-MRI sequence. Imaging results were correlated with available clinical symptoms.
Results
Eighteen of 56 GCA patients (32%) showed inflammatory changes of at least one of the intraorbital structures. The most common finding was enhancement of at least one of the optic nerve sheaths (N = 13, 72%). Vessel wall enhancement of the ophthalmic artery was unilateral in 8 and bilateral in 3 patients. Enhancement of the optic nerve was observed in one patient. There was no significant correlation between imaging features of inflammation and clinically reported orbital symptoms (p = 0.10). None of the age-matched control patients showed any inflammatory changes of intraorbital structures.
Conclusions
BB-MRI revealed inflammatory findings in the orbits in up to 32% of patients with GCA. Optic nerve sheath enhancement was the most common intraorbital inflammatory change on BB-MRI. MRI findings were independent of clinically reported orbital symptoms.
Key Points
• Up to 32% of GCA patients shows signs of inflammation of intraorbital structures on BB-MRI.
• Enhancement of the optic nerve sheath is the most common intraorbital finding in GCA patients on BB-MRI.
• Features of inflammation of intraorbital structures are independent of clinically reported symptoms.
Recent dissection studies resulted in the introduction of the term “chiasma antebrachii”, which represents an intersection of the flexor digitorum superficialis (FDS) tendons for digits 2 and 3 in the distal third of the forearm. This retrospective investigation aimed to provide an MRI-based morphologic analysis of the chiasma antebrachii. In 89 patients (41 women, 39.3 ± 21.3 years), MRI examinations of the forearm (2010–2021) were reviewed by two radiologists, who evaluated all studies for the presence and length of the chiasma as well as its distance from the distal radioulnar and elbow joint. The chiasma antebrachii was identified in the distal third of the forearm in 88 patients (98.9%), while one intersection was located more proximally in the middle part. The chiasma had a median length of 28 mm (interquartile range: 24–35 mm). Its distances to the distal radioulnar and elbow joint were 16 mm (8–25 mm) and 215 mm (187–227 mm), respectively. T1-weighted post-contrast sequences were found to be superior to T2- or proton-density-weighted sequences in 71 cases (79.8%). To conclude, the chiasma antebrachii is part of the standard FDS anatomy. Knowledge of its morphology is important, e.g., in targeted injections of therapeutics or reconstructive surgery.
Objectives: Dual-source dual-energy CT (DECT) facilitates reconstruction of virtual non-contrast images from contrast-enhanced scans within a limited field of view. This study evaluates the replacement of true non-contrast acquisition with virtual non-contrast reconstructions and investigates the limitations of dual-source DECT in obese patients. Materials and Methods: A total of 253 oncologic patients (153 women; age 64.5 ± 16.2 years; BMI 26.6 ± 5.1 kg/m\(^2\)) received both multi-phase single-energy CT (SECT) and DECT in sequential staging examinations with a third-generation dual-source scanner. Patients were allocated to one of three BMI clusters: non-obese: <25 kg/m\(^2\) (n = 110), pre-obese: 25–29.9 kg/m\(^2\) (n = 73), and obese: >30 kg/m\(^2\) (n = 70). Radiation dose and image quality were compared for each scan. DECT examinations were evaluated regarding liver coverage within the dual-energy field of view. Results: While arterial contrast phases in DECT were associated with a higher CTDI\(_{vol}\) than in SECT (11.1 vs. 8.1 mGy; p < 0.001), replacement of true with virtual non-contrast imaging resulted in a considerably lower overall dose-length product (312.6 vs. 475.3 mGy·cm; p < 0.001). The proportion of DLP variance predictable from patient BMI was substantial in DECT (R\(^2\) = 0.738) and SECT (R\(^2\) = 0.620); however, DLP of SECT showed a stronger increase in obese patients (p < 0.001). Incomplete coverage of the liver within the dual-energy field of view was most common in the obese subgroup (17.1%) compared with non-obese (0%) and pre-obese patients (4.1%). Conclusion: DECT facilitates a 30.8% dose reduction over SECT in abdominal oncologic staging examinations. Employing dual-source scanner architecture, the risk for incomplete liver coverage increases in obese patients.
Photon-counting detector (PCD) CT allows for ultra-high-resolution (UHR) examinations of the shoulder without requiring an additional post-patient comb filter to narrow the detector aperture. This study was designed to compare the PCD performance with a high-end energy-integrating detector (EID) CT. Sixteen cadaveric shoulders were examined with both scanners using dose-matched 120 kVp acquisition protocols (low-dose/full-dose: CTDI\(_{vol}\) = 5.0/10.0 mGy). Specimens were scanned in UHR mode with the PCD-CT, whereas EID-CT examinations were conducted in accordance with the clinical standard as “non-UHR”. Reconstruction of EID data employed the sharpest kernel available for standard-resolution scans (ρ\(_{50}\) = 12.3 lp/cm), while PCD data were reconstructed with both a comparable kernel (11.8 lp/cm) and a sharper dedicated bone kernel (16.5 lp/cm). Six radiologists with 2–9 years of experience in musculoskeletal imaging rated image quality subjectively. Interrater agreement was analyzed by calculation of the intraclass correlation coefficient in a two-way random effects model. Quantitative analyses comprised noise recording and calculating signal-to-noise ratios based on attenuation measurements in bone and soft tissue. Subjective image quality was higher in UHR-PCD-CT than in EID-CT and non-UHR-PCD-CT datasets (all p < 0.001). While low-dose UHR-PCD-CT was considered superior to full-dose non-UHR studies on either scanner (all p < 0.001), ratings of low-dose non-UHR-PCD-CT and full-dose EID-CT examinations did not differ (p > 0.99). Interrater reliability was moderate, indicated by a single measures intraclass correlation coefficient of 0.66 (95% confidence interval: 0.58–0.73; p < 0.001). Image noise was lowest and signal-to-noise ratios were highest in non-UHR-PCD-CT reconstructions at either dose level (p < 0.001). This investigation demonstrates that superior depiction of trabecular microstructure and considerable denoising can be realized without additional radiation dose by employing a PCD for shoulder CT imaging. Allowing for UHR scans without dose penalty, PCD-CT appears as a promising alternative to EID-CT for shoulder trauma assessment in clinical routine.
This study evaluated the influence of different vascular reconstruction kernels on the image quality of CT angiographies of the lower extremity runoff using a 1st-generation photon-counting-detector CT (PCD-CT) compared with dose-matched examinations on a 3rd-generation energy-integrating-detector CT (EID-CT). Inducing continuous extracorporeal perfusion in a human cadaveric model, we performed CT angiographies of eight upper leg arterial runoffs with radiation dose-equivalent 120 kVp acquisition protocols (CTDIvol 5 mGy). Reconstructions were executed with different vascular kernels, matching the individual modulation transfer functions between scanners. Signal-to-noise-ratios (SNR) and contrast-to-noise-ratios (CNR) were computed to assess objective image quality. Six radiologists evaluated image quality subjectively using a forced-choice pairwise comparison tool. Interrater agreement was determined by calculating Kendall’s concordance coefficient (W). The intraluminal attenuation of PCD-CT images was significantly higher than of EID-CT (414.7 ± 27.3 HU vs. 329.3 ± 24.5 HU; p < 0.001). Using comparable kernels, image noise with PCD-CT was significantly lower than with EID-CT (p ≤ 0.044). Correspondingly, SNR and CNR were approximately twofold higher for PCD-CT (p < 0.001). Increasing the spatial frequency for PCD-CT reconstructions by one level resulted in similar metrics compared to EID-CT (CNRfat; EID-CT Bv49: 21.7 ± 3.7 versus PCD-CT Bv60: 21.4 ± 3.5). Overall image quality of PCD-CTA achieved ratings superior to EID-CTA irrespective of the used reconstruction kernels (best: PCD-CT Bv60; worst: EID-CT Bv40; p < 0.001). Interrater agreement was good (W = 0.78). Concluding, PCD-CT offers superior intraluminal attenuation, SNR, and CNR compared to EID-CT in angiographies of the upper leg arterial runoff. Combined with improved subjective image quality, PCD-CT facilitates the use of sharper convolution kernels and ultimately bears the potential of improved vascular structure assessability.
Die vorliegende Arbeit hat zum Ziel, den Stellenwert von kontrastverstärkten MR- Sequenzen in der bildgebenden Diagnostik von Hand und Fingern zu untersuchen. Denn trotz einer breiten empirischen Anwendung von gadoliniumhaltigen Kontrastmitteln im europäischen Raum besteht keine ausreichende wissenschaftliche Datengrundlage zur kontrastverstärkten Hand-MRT nach einem Trauma. Zu diesem Zweck wurden zwischen Januar 2016 und August 2018 am Rhön-Klinikum Campus Bad Neustadt 165 MRT-Untersuchungen von distalem Unterarm, Karpus, Metakarpus und/oder Fingern selektiert. Einschlusskriterien waren eine positive Traumaanamnese, standardisierte MRT-Sequenzen und das Fehlen von Kontraindikationen.
Zur Definition eines diagnostischen Referenzstandards wurden alle Fälle vorab durch einen Senior-Investigator mit 36 Jahren Erfahrung in muskuloskelettaler Radiologie analysiert. Für die Bildevaluation wurden aus jeder MRT-Untersuchung zwei Datensätze erstellt, wobei der erste Datensatz nur die nativen Sequenzen (PD / T2 FSE fs und T1 FSE ) und der zweite Datensatz zusätzlich zu eine kontrastverstärkte Sequenz als T1 FSE fs nach Gadolinium-Applikation enthielt. Als Observer fungierten zwei radiologische Fach- bzw. Oberärzte des Universitätsklinikum Würzburgs.
In der vorliegenden Studie wurde ein diagnostisch relevantes Kontrastmittelenhancement an Patienten mit traumatischen Handverletzungen nachgewiesen. Der Kontrastmitteleffekt war mit subjektiven und objektiven Messgrößen statistisch signifikant bei Läsionen der Ligamente und an den ligamentähnlichen Insertionen des ulnaren TFCC-Abschnittes. Als Erklärung für das Kontrastmittelenhancement in der MRT dient in erster Linie die bereits früher beschriebene Hyperämie, die posttraumatisch am Traumaort mit Ausgang von der Synovialis entsteht.
Anhand der Studienergebnisse kann die Empfehlung ausgesprochen werden, in der MRT-Diagnostik von traumatischen Läsionen der Hand immer dann intravenöses Kontrastmittel auf Gadolinium-Basis zu verabreichen, wenn am vermuteten Läsionsort der T2-Kontrast für eine sichere Diagnose unzureichend ist.