Lehrstuhl für Orthopädie
Refine
Is part of the Bibliography
- yes (373)
Year of publication
Document Type
- Doctoral Thesis (214)
- Journal article (157)
- Book (1)
- Other (1)
Keywords
- mesenchymal stem cells (15)
- Osteoporose (14)
- osteoporosis (12)
- total knee arthroplasty (12)
- Schultergelenk (11)
- Rotatorenmanschette (10)
- tissue engineering (9)
- Hüftgelenk (8)
- Mesenchymale Stammzellen (8)
- Revision (8)
Institute
- Lehrstuhl für Orthopädie (373) (remove)
Sonstige beteiligte Institutionen
- IZKF Nachwuchsgruppe Geweberegeneration für muskuloskelettale Erkrankungen (7)
- Bernhard-Heine-Centrum für Bewegungsforschung (4)
- König-Ludwig-Haus Würzburg (3)
- Orthopädische Klinik und Poliklinik der Universität Würzburg (2)
- König Ludwig Haus Würzburg (1)
- König-Ludwig Haus (1)
- Lehrstuhl für Regeneration Muskuloskelettaler Gewebe (1)
- Muskuloskelettalen Zentrum Würzburg (MCW) (1)
- Muskuloskelettales Centrum Würzburg (MCW) (1)
- Orthopädische Klinik König-Ludwig-Haus (1)
- Orthopädische Klinik König-Ludwig-Haus Würzburg (1)
- Orthopädische Klinik und Poliklinik "König-Ludwig-Haus" der Uni Würzburg (1)
- Rhön-Klinikum Campus Bad Neustadt an der Saale, Klinik für Handchirurgie (1)
In der Revisionsendoprothetik des Hüftgelenks bietet ein modulares Schaftsystem die Möglichkeit der intraoperativen Anpassung an die individuellen anatomischen Gegebenheiten. Dies ist eine Untersuchung des klinisch-radiologischen Outcomes des MRP-Revisionsschafts mit diaphysärer Fixation in der Revisionschirurgie. Der MRP-Revisionsschaft zeigt ein zufriedenstellendes klinisches Outcome.
Schultererkrankungen nehmen in sozioökonomischer Hinsicht einen Spitzenplatz unter den Erkrankungen des Bewegungsapparates ein.58 Die häufigen „klassischen Schultererkrankungen“ wie Schulterinstabilitäten, Rotatorenmanschettenrupturen und Omarthrosen sind schon sehr lange bekannt und durch viele Studien gut untersucht. Demgegenüber stellen Läsionen des Aufhängeapparates der langen Bizepssehne (LBS) eine sehr junge Schulterpathologie dar, über die es noch wenige Daten gibt. Im Jahre 1994 formten Walch et al.62 für diese komplexe intraartikuläre Halteschlinge der LBS den Begriff des „stabilizing pulley“, oder Bizepspulley. Im Folgenden sollen Anatomie, Funktion und Pathologie des Bizepspulleys mit allen wichtigen anatomischen Strukturen kurz erläutert werden.
Retrospektive prä- und postoperative radiologische Datenauswertung patientenspezifischer Kniegelenksendoprothetik – ConforMIS iTotal® CR, iDuo® und iUni® G2.
Vergleich und Diskussion der Daten hinsichtlich mechanischer Beinachse, Patellahöhe und -ausrichtung und Komponentendimensionierung und -ausrichtung.
Revision Arthroplasty Through the Direct Anterior Approach Using an Asymmetric Acetabular Component
(2020)
Despite increasing numbers of primary hip arthroplasties performed through the direct anterior approach (DAA), there is a lack of literature on DAA revision arthroplasty. The present study was performed in order to evaluate outcomes and revision rates after revision through the DAA using an asymmetric acetabular component with optional intra- and extramedullary fixation. In a retrospective cohort study, we analyzed prospectively collected data of 57 patients (61 hips, 43 female, 18 male) who underwent aseptic acetabular component revision through the DAA with the abovementioned implant system between January 2015 and December 2017. The mean follow-up was 40 months (12–56). Survival rates were estimated using the Kaplan–Meier method. All complications were documented and functional outcomes were assessed pre- and postoperatively. Kaplan–Meier analysis revealed an estimated five-year implant survival of 97% (confidence interval CI 87–99%). The estimated five-year survival with revision for any cause was 93% (CI 83–98%). The overall revision rate was 6.6% (n = 4). Two patients had to undergo revision due to periprosthetic infection (3.3%). In one patient, the acetabular component was revised due to aseptic loosening four months postoperatively. Another patient suffered from postoperative iliopsoas impingement and was treated successfully by arthroscopic iliopsoas tenotomy. Two (3.3%) of the revised hips dislocated postoperatively. The mean Harris Hip Score improved from 35 (2–66) preoperatively to 86 (38–100) postoperatively (p < 0.001). The hip joint’s anatomical center of rotation was restored at a high degree of accuracy. Our findings demonstrate that acetabular revision arthroplasty through the DAA using an asymmetric acetabular component with optional intra- and extramedullary fixation is safe and practicable, resulting in good radiographic and clinical midterm results.
Background: Revision in failed shoulder arthroplasty often requires removal of the humeral component with a significant risk of fracture and bone loss. Newer modular systems allow conversion from anatomic to reverse shoulder arthroplasty with retention of a well-fixed humeral stem. We report on a prospectively evaluated series of conversions from hemiarthroplasty to reverse shoulder arthroplasty.
Methods: In 14 cases of failed hemiarthroplasty due to rotator cuff deficiency and painful pseudoparalysis (in 13 women), revision to reverse shoulder arthroplasty was performed between October 2006 and 2010, with retention of the humeral component using modular systems. Mean age at the time of operation was 70 (56-80) years. Pre- and postoperative evaluation followed a standardized protocol including Constant score, range of motion, and radiographic analysis. Mean follow-up time was 2.5 (2-5.5) years.
Results: Mean Constant score improved from 9 (2-16) to 41 (17-74) points. Mean lengthening of the arm was 2.6 (0.9-4.7) cm without any neurological complications. One patient required revision due to infection. Interpretation Modular systems allow retainment of a well-fixed humeral stem with good outcome. There is a risk of excessive humeral lengthening.
Evaluation anhand eines Fragebogens bezüglich der Tätigkeiten und der Intensität der Tätigkeiten verschiedener Berufsgruppen. Prüfung des Zusammenhangs bestimmter beruflicher Tätigkeiten und dem vermehrten Aufkommen von Rotatorenmanschettendefekten. Es konnte ein vermehrtes Aufkommen von Arbeitern des Baugewerbes und der Land und Forstwirtschaft und von Tätigkeiten in und über Schulterhöhe sowie Heben schwerer Lasten und Arbeiten mit vibrierenden Geräten festgestellt werden.
Sarcopenia and Malnutrition Screening in Female Osteoporosis Patients — A Cross-Sectional Study
(2021)
Sarcopenia and malnutrition are important determinants of increased fracture risk in osteoporosis. SARC-F and MNA-SF are well-established questionnaires for identifying patients at risk for these conditions. We sought to evaluate the feasibility and potential added benefit of such assessments as well as the actual prevalence of these conditions in osteoporosis patients. We conducted a cross-sectional, single-center study in female osteoporosis patients ≥ 65 years (SaNSiBaR-study). Results of the sarcopenia (SARC-F) and malnutrition (MNA-SF) screening questionnaires were matched with a functional assessment for sarcopenia and data from patients’ medical records. Out of 107 patients included in the analysis, a risk for sarcopenia (SARC-F ≥ 4 points) and a risk for malnutrition (MNA-SF ≤ 11 points) was found in 33 (30.8%) and 38 (35.5%) patients, respectively. Diagnostic overlap with coincident indicative findings in both questionnaires was observed in 17 patients (16%). As compared to the respective not-at-risk groups, the mean short physical performance battery (SPPB) score was significantly reduced in both patients at risk for sarcopenia (7.0 vs. 10.9 points, p < 0.001) and patients at risk for malnutrition (8.7 vs. 10.5 points, p = 0.005). Still, confirmed sarcopenia according to EWGSOP2 criteria was present in only 6 (6%) of all 107 patients, with only 3 of them having an indicative SARC-F score. Bone mineral density was not significantly different in any of the at-risk groups at any site. In summary, applying SARC-F and MNA-SF in osteoporosis patients appears to be a complementary approach to identify individuals with functional deficits.
Hintergrund: Die Entwicklung minimal-invasiver gewebeschonender Zugangswege in der Hüftendoprothetik ist im Allgemeinen mit einer schnelleren Rehabilitation, einer Verringerung der postoperativen Schmerzen und einem erhöhten Patientenkomfort verbunden. Das Ziel dieser Studie war es, einen anterioren minimal-invasiven mit einem transglutealen lateralen Zugangsweg für Hüftgelenksersatzoperationen in Bezug auf postoperatives Schmerzniveau, den Schmerzmittelgebrauch, die Länge des Krankenhausaufenthalts und die Zeit bis zum Erreichen eines definierten physiotherapeutischen Therapiezieles zu vergleichen.
Methoden: In dieser retrospektiven Kohortenstudie untersuchten wir 200 Patienten, die sich einer Hüftendoprothesenimplantation unterzogen. Gruppe I (n = 100) erhielt einen minimal-invasiven anterioren Hüftzugang (modifiziert nach Smith-Peterson), Gruppe II (n = 100) erhielt einen lateralen transglutealen Zugang (nach Bauer). Die Untersuchungsziele waren der Schmerz in Ruhe und während der Physiotherapie, der Schmerzmittelgebrauch, die Länge des stationären Aufenthaltes sowie die Zeitdauer bis zum Erreichen des physiotherapeutischen Therapiezieles.
Ergebnisse: Die Patienten der Gruppe I konsumierten weniger Schmerzmedikamente (19,6 ± 6,9 mg Piritramid gegenüber 23,6 ± 11,3 mg; p = 0,005) und hatten in der frühen postoperativen Phase weniger Schmerzen (Operationstag: VAS 1,3 ± 1 gegenüber 2,3 ± 1,3, p = 0,0001, erster postoperativer Tag: VAS 0,41 ± 0,8 vs. 0,66 ± 1,1, p = 0,036). Die Zeit bis zum Erreichen des definierten Therapiezieles (6,4 ± 2 Tage gegenüber 7,4 ± 2,1 Tagen; p = 0,001) und die Dauer des Krankenhausaufenthalts waren kürzer (10,2 ± 1,9 Tage gegenüber 13,4 ± 1,6 Tagen; p = 0,0001) für Gruppe I. Die Schmerzen während der Physiotherapie waren jedoch am dritten und sechsten bis neunten Tag nach der Operation im Vergleich zu Gruppe II höher (p = 0,001–0,013).
Schlussfolgerung: Die Implantation einer Hüftprothese über einen minimal-invasiven anterioren Zugang führt in der direkt postoperativen Phase zu einer Reduktion des Schmerzniveaus und des Schmerzmittelgebrauchs. Zusätzlich werden das Erreichen des physiotherapeutischen Therapiezieles und die Länge des stationären Aufenthaltes positiv beeinflusst. Den höheren Schmerzen während der Physiotherapie könnte durch eine Reduktion der erlaubten Gewichtsbelastung in der frühen postoperativen Phase entgegengewirkt werden.
Hintergrund:
Die vorgestellten Daten demonstrieren das klinische Ergebnis von Patienten, die sich eine Hüfttotalendoprothese (THA) unterzogen haben. Als Zugangsweg wurde der minimal-invasive, direkt anteriore Zugang in Einzelschnitttechnik gewählt (MIS-DAA). Die Patientin wurden bis zwölf Monate nach Operation beobachtet.
Methoden:
Es wurden die Daten von 73 Probanden mittels der folgenden Fragebogen ausgewertet: Harris Hip Score (HHS), eXtra Short Musculoskeletal Functional Assessment questionnaire (XSFMA), Short Form 36 (SF-36) health survey und Patient Health Questionaire 9 „deutsch“ (PHQ-9 D). Zur Schmerzmessung kam eine visuelle Analogskala (VAS von 0-4) zum Einsatz. Daneben wurde die Aktivität mit Hilfe des Schrittzählers Stepwatch™ Activity Monitor (SAM) und eines 25m Gehtests auf Zeit (T25-FW) erfasst. Während der gesamten Aufzeichnung wurden auch Komplikationen erfasst.
Ergebnisse:
Zwölf Monate nach der Operation verbesserten sich die HHS-Werte signifikant von 55,2 präoperativ auf 92,4 (Werte 0 – 100). Der FSFMA Funktionsscore fiel ebenfalls signifikant von 39,4 auf 10,3 und der Beeintrachtigungsscore von 47,0 auf 15,8. Der Score für die Physis (PCS) stieg im SF 36 signifikant von 27,5 präoperativ auf 47,5 nach zwölf Monaten. Der Score für mentale Gesundheit (MCS) fiel dagegen sogar leicht von 57,6 auf 55,0. Dagegen fiel die Prävalenz der mittels PHQ-9 D gemessenen Somatisierungsstörungen von elf auf einen Fall. Die Schmerzreduktion durch die Operation zeigte sich durch einen Rückgang auf der VAS von 2,41 auf 0,35 zwölf Monate postoperativ. Die durchschnittlich täglich absolvierten Lastwechsel nahmen laut Schrittzählermessung signifikant von 5113 präoperativ auf 6402 zu. Außerdem stieg die Gehgeschwindigkeit im T25-FW signifikant von 22,06 s (= 1,13 m/s) auf 18,14 s (= 1,38 m/s). Es wurden keine schwerwiegenden Komplikationen, wie z.B. Transplantatlockerungen, festgestellt.
Zusammenfassung:
In der Zusammenschau der Ergebnisse zeigt sich ein Jahr nach MIS-DAA-THA, dass die Patienten eine signifikant bessere Funktion, Aktivität und weniger Schmerzen aufweisen. Der MIS-DA-Zugang ist sicher und weist keine erhöhte Komplikationsrate auf.
Im Zeitraum von Juni 2001 bis Februar 2005 wurden an der Orthopädischen Klinik König-Ludwig-Haus insgesamt 47 Revisionsoperationen unter Verwendung der reversen Endoprothese nach Grammont durchgeführt. Dabei handelte es sich um 31 Wechseloperationen nach fehlgeschlagener Frakturprothese und 14 Revisionen nach osteosynthetischer Versorgung. Zum Zeitpunkt der Operation lag das mittlere Lebensalter bei 66,8 Jahren. In 27 Fällen war die dominante Seite betroffen. Die Anzahl der Voroperationen betrug im Durchschnitt 1,96 (1-8). Die klinische und radiologische Kontrolluntersuchung erfolgte im Mittel 20,9 Monate postoperativ. Die Ergebnisse wurden anhand des Constant-Score erhoben. Zum Zeitpunkt der Nachuntersuchung zeigten sich 38% (18 Fälle) der Patienten mit dem Ergebnis der Operation sehr zufrieden und 53% (25 Fälle) zufrieden, alle Patienten würden den Eingriff erneut durchführen lassen. Der alters- und geschlechtsadaptierte Constant-Score betrug präoperativ 19% und verbesserte sich postoperativ auf 66%. Es wurde in allen Fällen eine deutliche Schmerzreduktion erzielt. Der aktive Bewegungsumfang und damit die Funktionalität der Schulter konnte deutlich gesteigert werden. Zum Zeitpunkt der Nachuntersuchung fanden sich in der radiologischen Untersuchung keine gelockerten Implantate. In sieben Fällen (14,9%) traten revisionsbedürftige Komplikationen auf. Hinsichtlich der vorausgehenden Versorgung ließen sich nach fehlgeschlagener Osteosynthese tendenziell bessere Ergebnisse erzielen als bei Wechseloperationen nach Frakturprothese.