Effects of image homogeneity on stenosis visualization at 7 T in a coronary artery phantom study: With and without B1-shimming and parallel transmission
Zitieren Sie bitte immer diese URN: urn:nbn:de:bvb:20-opus-300129
- Background To investigate the effects of B\(_1\)-shimming and radiofrequency (RF) parallel transmission (pTX) on the visualization and quantification of the degree of stenosis in a coronary artery phantom using 7 Tesla (7 T) magnetic resonance imaging (MRI). Methods Stenosis phantoms with different grades of stenosis (0%, 20%, 40%, 60%, 80%, and 100%; 5 mm inner vessel diameter) were produced using 3D printing (clear resin). Phantoms were imaged with four different concentrations of diluted Gd-DOTA representing established arterialBackground To investigate the effects of B\(_1\)-shimming and radiofrequency (RF) parallel transmission (pTX) on the visualization and quantification of the degree of stenosis in a coronary artery phantom using 7 Tesla (7 T) magnetic resonance imaging (MRI). Methods Stenosis phantoms with different grades of stenosis (0%, 20%, 40%, 60%, 80%, and 100%; 5 mm inner vessel diameter) were produced using 3D printing (clear resin). Phantoms were imaged with four different concentrations of diluted Gd-DOTA representing established arterial concentrations after intravenous injection in humans. Samples were centrally positioned in a thorax phantom of 30 cm diameter filled with a custom-made liquid featuring dielectric properties of muscle tissue. MRI was performed on a 7 T whole-body system. 2D-gradient-echo sequences were acquired with an 8-channel transmit 16-channel receive (8 Tx / 16 Rx) cardiac array prototype coil with and without pTX mode. Measurements were compared to those obtained with identical scan parameters using a commercially available 1 Tx / 16 Rx single transmit coil (sTX). To assess reproducibility, measurements (n = 15) were repeated at different horizontal angles with respect to the B0-field. Results B\(_1\)-shimming and pTX markedly improved flip angle homogeneity across the thorax phantom yielding a distinctly increased signal-to-noise ratio (SNR) averaged over a whole slice relative to non-manipulated RF fields. Images without B\(_1\)-shimming showed shading artifacts due to local B\(_1\)\(^+\)-field inhomogeneities, which hampered stenosis quantification in severe cases. In contrast, B\(_1\)-shimming and pTX provided superior image homogeneity. Compared with a conventional sTX coil higher grade stenoses (60% and 80%) were graded significantly (p<0.01) more precise. Mild to moderate grade stenoses did not show significant differences. Overall, SNR was distinctly higher with B\(_1\)-shimming and pTX than with the conventional sTX coil (inside the stenosis phantoms 14%, outside the phantoms 32%). Both full and half concentration (10.2 mM and 5.1 mM) of a conventional Gd-DOTA dose for humans were equally suitable for stenosis evaluation in this phantom study. Conclusions B\(_1\)-shimming and pTX at 7 T can distinctly improve image homogeneity and therefore provide considerably more accurate MR image analysis, which is beneficial for imaging of small vessel structures.…
Autor(en): | Stefan Herz, Maria R. Stefanescu, David Lohr, Patrick Vogel, Aleksander Kosmala, Maxim Terekhov, Andreas M. Weng, Jan-Peter Grunz, Thorsten A. Bley, Laura M. Schreiber |
---|---|
URN: | urn:nbn:de:bvb:20-opus-300129 |
Dokumentart: | Artikel / Aufsatz in einer Zeitschrift |
Institute der Universität: | Fakultät für Physik und Astronomie / Physikalisches Institut |
Medizinische Fakultät / Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) | |
Medizinische Fakultät / Deutsches Zentrum für Herzinsuffizienz (DZHI) | |
Sprache der Veröffentlichung: | Englisch |
Titel des übergeordneten Werkes / der Zeitschrift (Englisch): | PloS One |
Erscheinungsjahr: | 2022 |
Band / Jahrgang: | 17 |
Heft / Ausgabe: | 6 |
Aufsatznummer: | e0270689 |
Originalveröffentlichung / Quelle: | PloS One (2022) 17:6, e0270689. https://doi.org/ 10.1371/journal.pone.027068 |
DOI: | https://doi.org/10.1371/journal.pone.0270689 |
Allgemeine fachliche Zuordnung (DDC-Klassifikation): | 6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit |
Freie Schlagwort(e): | 3D printing; coronary arteries; image processing; in vivo imaging; magnetic resonance imaging; signal to noise ratio; stenosis; thorax |
Datum der Freischaltung: | 03.05.2023 |
Sammlungen: | Open-Access-Publikationsfonds / Förderzeitraum 2022 |