Lehrstuhl für Orthopädie
Refine
Is part of the Bibliography
- yes (378)
Year of publication
Document Type
- Doctoral Thesis (216)
- Journal article (160)
- Book (1)
- Other (1)
Keywords
- mesenchymal stem cells (15)
- Osteoporose (14)
- osteoporosis (12)
- total knee arthroplasty (12)
- Schultergelenk (11)
- Rotatorenmanschette (10)
- tissue engineering (9)
- Hüftgelenk (8)
- Mesenchymale Stammzellen (8)
- Revision (8)
Institute
- Lehrstuhl für Orthopädie (378)
- Klinik und Poliklinik für Unfall-, Hand-, Plastische und Wiederherstellungschirurgie (Chirurgische Klinik II) (15)
- Abteilung für Funktionswerkstoffe der Medizin und der Zahnheilkunde (7)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (7)
- Theodor-Boveri-Institut für Biowissenschaften (7)
- Medizinische Klinik und Poliklinik II (6)
- Graduate School of Life Sciences (5)
- Lehrstuhl für Tissue Engineering und Regenerative Medizin (5)
- Kinderklinik und Poliklinik (4)
- Pathologisches Institut (4)
- Institut für Humangenetik (3)
- Institut für Pharmazie und Lebensmittelchemie (3)
- Medizinische Fakultät (3)
- Institut für Anatomie und Zellbiologie (2)
- Institut für Hygiene und Mikrobiologie (2)
- Institut für Virologie und Immunbiologie (2)
- Poliklinik für Zahnerhaltung und Parodontologie (2)
- Abteilung für Parodontologie (in der Poliklinik für Zahnerhaltung und Parodontologie) (1)
- Comprehensive Cancer Center Mainfranken (1)
- Fakultät für Mathematik und Informatik (1)
- Institut für Molekulare Infektionsbiologie (1)
- Institut für Organische Chemie (1)
- Institut für Pharmakologie und Toxikologie (1)
- Institut für diagnostische und interventionelle Neuroradiologie (ehem. Abteilung für Neuroradiologie) (1)
- Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I) (1)
- Klinik und Poliklinik für Anästhesiologie (ab 2004) (1)
- Klinik und Poliklinik für Hals-, Nasen- und Ohrenkrankheiten, plastische und ästhetische Operationen (1)
- Medizinische Klinik und Poliklinik I (1)
- Neurochirurgische Klinik und Poliklinik (1)
- Universität Würzburg (1)
Sonstige beteiligte Institutionen
- IZKF Nachwuchsgruppe Geweberegeneration für muskuloskelettale Erkrankungen (7)
- Bernhard-Heine-Centrum für Bewegungsforschung (4)
- König-Ludwig-Haus Würzburg (3)
- Orthopädische Klinik und Poliklinik der Universität Würzburg (2)
- König Ludwig Haus Würzburg (1)
- König-Ludwig Haus (1)
- Lehrstuhl für Regeneration Muskuloskelettaler Gewebe (1)
- Muskuloskelettalen Zentrum Würzburg (MCW) (1)
- Muskuloskelettales Centrum Würzburg (MCW) (1)
- Orthopädische Klinik König-Ludwig-Haus (1)
Premature implant loosening following total knee arthroplasty (TKA) can have several causes. In this article we report on a rare case of a 74 year old male patient suffering tibial component loosening 14 month after primary TKA. The patient did neither have any malignancies nor joint arthroplasty before. Upon clinical examination the range of motion in the diseased knee was painfully restricted to 80° of knee flexion, with the patient increasingly suffering sleeping and resting pain, and also at weight bearing. In standard radiographs, loosening of the TKA due to a large osteolysis at the tibial component was evident. Local computed tomography (CT) of the right knee revealed loosening of the tibial component due to a presumably malign bone tumor. For determination of the final diagnosis a representative biopsy of the tumor was taken by open surgery prior to the tumor resection. Histopathologic evaluation of the biopsy revealed a periprosthetic myxoid chondrosarcoma of the proximal tibia. Pre-operative staging examination included CT scans of lung and abdomen, as well as a bone scintigraphy which revealed no signs of tumor metastasis in the body. Surgical management comprised wide tumor resection and implantation of a hinged tumor knee arthroplasty with replacements of the distal femur and proximal tibia, as well as a patella tendon replacement using a synthetic ligament. Revision surgery was necessary twice due to impaired wound healing and critical soft tissue coverage, and treatment included a gastrocnemius muscle flap with skin mesh graft covering. Unfortunately long-term follow-up examinations could not be obtained, as the patient deceased due to an alveolitis during rehabilitation. In summary, the specifics of this rare case of aseptic TKA loosening, and the unusual circumstances of chondrosarcoma diagnosis and treatment are informative for those providing surgical treatment of similar cases.
1,25-dihydroxyvitamin D3 (1,25D3) was reported to induce premature organismal aging in fibroblast growth factor-23 (Fgf23) and klotho deficient mice, which is of main interest as 1,25D3 supplementation of its precursor cholecalciferol is used in basic osteoporosis treatment. We wanted to know if 1,25D3 is able to modulate aging processes on a cellular level in human mesenchymal stem cells (hMSC). Effects of 100 nM 1,25D3 on hMSC were analyzed by cell proliferation and apoptosis assay, beta-galactosidase staining, VDR and surface marker immunocytochemistry, RT-PCR of 1,25D3-responsive, quiescence-and replicative senescence-associated genes. 1,25D3 treatment significantly inhibited hMSC proliferation and apoptosis after 72 h and delayed the development of replicative senescence in long-term cultures according to beta-galactosidase staining and P16 expression. Cell morphology changed from a fibroblast like appearance to broad and rounded shapes. Long term treatment did not induce lineage commitment in terms of osteogenic pathways but maintained their clonogenic capacity, their surface marker characteristics (expression of CD73, CD90, CD105) and their multipotency to develop towards the chondrogenic, adipogenic and osteogenic pathways. In conclusion, 1,25D3 delays replicative senescence in primary hMSC while the pro-aging effects seen in mouse models might mainly be due to elevated systemic phosphate levels, which propagate organismal aging.
Bei der Implantation von Hüfttotalendoprothesen (HTEP) finden seit etwa 15 Jahren minimalinvasive muskelschonende Zugänge zunehmend Verwendung. Langfristige Daten der Zugänge, insbesondere des minimalinvasiven anterolateralen Zuganges nach Watson-Jones (ALMI) sind in der Literatur bisher nur unzureichend vorhanden.
Methodik: Ziel dieser Studie war es ein Kollektiv nach HTEP Implantation mit ALMI Zugang mit einem Kollektiv nach HTEP Implantation mit lateralem Zugang nach 10 Jahren hinsichtlich Gelenksfunktion, Muskelfunktion, Zufriedenheit und radiologischer Parameter zu vergleichen und etwaige Unterschiede in der Langzeitbilanz zu detektieren.
Zwei Kollektive mit jeweils 29 operierten Hüftgelenken, Erstimplantation durch die gleichen Operateure in den Jahren 2005 bis 2008, wurden im Diakoniewerk München-Maxvorstadt nachuntersucht. Die dafür herangezogenen Parameter waren Harris Hip Score, Forgotten Joint Score-12, klinische Prüfung des Trendelenburg Zeichens, postoperative Röntgenbildgebung, Auftreten von Komplikationen und Narbenlänge.
Ergebnisse & Schlussfolgerungen: Die beiden Kollektive zeigten in den Parametern Harris Hip Score, Forgotten Joint Score und klinische Prüfung des Trendelenburg Zeichens geringfügige Unterschiede zugunsten des ALMI Kollektivs, die jedoch nicht signifikant waren. Beide Kollektive erreichten in den beschriebenen Scores sehr gute bis exzellente Ergebnisse nach 10 Jahren. Das geringere Auftreten eines auffälligen Trendelenburg Zeichens im ALMI Kollektiv (13,8 vs. 6,9 %) gibt Hinweise auf eine verbesserte Funktion der Glutealmuskulatur durch die intraoperative Muskelschonung. Die beiden Zugänge zeigten in den radiologischen Parametern und der Komplikationsrate ebenbürtige Ergebnisse. Vermehrte Fehlpositionierungen wurden im ALMI Kollektiv nicht beobachtet.
Unsere Beobachtungen passen zu den wenigen vorhandenen in der Literatur beschriebenen Ergebnissen von minimalinvasiven muskelschonenden Zugängen in der Langzeitbilanz.
In den letzten Jahrzehnten ist die Anzahl der degenerativen Gelenkerkrankungen wie die Coxarthrose und somit die Zahl der zu implantierenden Hüfttotalendoprothesen stark gestiegen. Ziel der vorliegenden Arbeit ist es, langfristige Ergebnisse zementierter Titanschaftprothesen in Bezug auf aseptische Lockerungen zu ermitteln. Von den in der Orthopädischen Universitätsklinik Würzburg implantierten Hüfttotalendoprothesen von Januar 1990 bis März 1992 konnten nach durchschnittlich 9 Jahren 110 Hüfttotalendoprothesen klinisch und radiologisch nachuntersucht werden. Zum Zeitpunkt der Kontrolluntersuchung hatten die Patienten ein mittleres Alter von 76 Jahren. In allen Fällen wurden Müller-Geradschaftprothesen mit einer Ti-6A1-7Nb-Legierung in matter Oberfläche, Biolox®-Keramik-Köpfe sowie Knochenzement Palacos-® verwendet. Es wurde bei 4 Hüft-TEPs wegen aseptischer Lockerung ein Prothesenwechsel durchgeführt. Das nachuntersuchte Patientengut wurde in 3 Gruppen eingeteilt. Gruppe A rekrutierte sich aus denjenigen Patienten, bei denen keine radiologischen Lockerungszeichen erkennbar waren. Die Patienten mit mehr als einem Lysesaum jedoch mit festem Sitz der Schaftprothese im Vergleich zu den postoperativen Röntgenbildern wurden der Gruppe B zugeordnet. Letztendlich bildeten die Patienten mit ausgeprägten Lockerungszeichen bzw. vollständig gelockerte Prothesen die Gruppe C. Der Harris-Hip-Score der Gruppe A mit 85 ( 13) Punkten und der Gruppe B mit 86 ( 14) Punkten zeigte gute Ergebnisse. Der Harris-Score lag in der Gruppe C bei 76 (± 5) Punkten und erreichte somit ein mäßiges Ergebnis. Im Vergleich zu den Gruppen A und B erwies sich diese Punktezahl als signifikant schlechter. Die Patienten mit ausgeprägten Lockerungszeichen waren signifikant jünger (im Mittel 6 Jahre) als die der Gruppe ohne Lockerungssäume. Ebenfalls fanden wir einen signifikanten Unterschied im Bezug auf das Körpergewicht, Körpergewicht im Verhältnis zu zementierter Schaftoberfläche und Harris-Score (88 vs. 75 kg; 1,5 vs. 1,0 kg/cm; 76 vs. 85). Für Geschlecht, Schaftgröße, Schaftart, Aktivität, heterotope Ossifikationen und Body-Maß-Index traf dies nicht zu. Unter Berücksichtigung der erhobenen Daten (Harris-Hüft-Score und Quotient des Körpergewichts zur zementierten Schaftoberfläche) sollte eine möglichst große Prothese implantiert werden, um das Körpergewicht auf eine große Schaftoberfläche zu verteilen. Insgesamt hat sich die zementierte Müller-Geradschaftprothese aus Titanlegierung bewährt, so dass sie für die Behandlung von Nickelallergiker zu empfehlen ist.
Background:
The presented prospective randomized controlled single-centre study compares the clinical outcome up to 12 months after total hip arthroplasty using a minimally invasive single-incision direct anterior (DAA) and a direct transgluteal lateral approach.
Methods:
A total of 123 arthroplasties were evaluated utilizing the Harris Hip Score (HHS), the extra short musculoskeletal functional assessment questionnaire (XSFMA), the Short Form 36 (SF-36) health survey, a Stepwatch™ Activity Monitor (SAM), and a timed 25 m foot walk (T25-FW). Postoperative x-ray images after THA were reviewed to determine inclination and stem positioning.
Results:
At final follow-up, the XSFMA functional index scores were 10.3 (anterior) and 15.08 (lateral) while the bother index summed up to a score of 15.8 (anterior) and 21.66 (lateral) respectively, thus only differing significantly for the functional index (p = 0.040 and p = 0.056). The SF-36 physical component score (PCS) was 47.49 (anterior) and 42.91 (lateral) while the mental component score (MCS) summed up to 55.0 (anterior) and 56.23 (lateral) with a significant difference evident for the PCS (p = 0.017; p = 0.714). Patients undergoing THA through a DAA undertook a mean of 6402 cycles per day while those who had undergone THA through a transgluteal approach undertook a mean of 5340 cycles per day (p = 0.012). Furthermore, the obtained outcome for the T25-FW with 18.4 s (anterior) and 19.75 s (lateral) and the maximum walking distance (5932 m and 5125 m) differed significantly (p = 0.046 and p = 0.045). The average HHS showed no significant difference equaling 92.4 points in the anterior group and 91.43 in the lateral group (p = 0.477). The radiographic analysis revealed an average cup inclination of 38.6° (anterior) and 40.28° (lateral) without signs of migration.
Conclusion:
In summary, our outcomes show that after 1 year THA through the direct anterior approach results in a higher patient activity compared to THA utilizing a transgluteal lateral approach while no differences regarding hip function are evident.
Mechanical forces are translated into biochemical signals and contribute to cell differentiation and phenotype maintenance. Mesenchymal stem cells and their tissuespecific offspring, as osteoblasts and chondrocytes, cells of cardiovascular tissues and lung cells are sensitive to mechanical loading but molecules and mechanisms involved have to be unraveled. It is well established that cellular mechanotransduction is mediated e.g. by activation of the transcription factor SP1 and by kinase signaling cascades resulting in the activation of the AP1 complex. To investigate cellular mechanisms involved in mechanotransduction and to analyze substances, which modulate cellular mechanosensitivity reporter gene constructs, which can be transfected into cells of interest might be helpful. Suitable small-scale bioreactor systems and mechanosensitive reporter gene constructs are lacking. To analyze the molecular mechanisms of mechanotransduction and its crosstalk with biochemically induced signal transduction, AP1 and SP1 luciferase reporter gene constructs were cloned and transfected into various cell lines and primary cells. A newly developed bioreactor and small-scale 24-well polyurethane dishes were used to apply cyclic stretching to the transfected cells. 1 Hz cyclic stretching for 30 min in this system resulted in a significant stimulation of AP1 and SP1 mediated luciferase activity compared to unstimulated cells. In summary we describe a small-scale cell culture/bioreactor system capable of analyzing subcellular crosstalk mechanisms in mechanotransduction, mechanosensitivity of primary cells and of screening the activity of putative mechanosensitizers as new targets, e.g. for the treatment of bone loss caused by both disuse and signal transduction related alterations of mechanotransduction.
After starting an orthopedic practice, a surgeon with a fellowship in mechanically aligned (MA) TKA initiated this study to characterize their learning curve after they switched to unrestricted kinematic alignment (KA) TKA using manual instruments. Accordingly, the present study determined for the inexperienced (IE) surgeon the number of cases required to achieve consistent femoral resections and operating times, and whether the femoral resection accuracy, patient-reported outcome measures (PROMs), and component alignment were different from an experienced (E) surgeon. This prospective cohort study analyzed the IE surgeon's first 30 TKAs, all performed with KA, and 30 consecutive KA TKAs performed by an E surgeon. The resection accuracy or deviation was the calipered thickness of the distal and posterior medial and lateral femoral resections minus the planned resection thickness, which was the thickness of the corresponding condyle of the femoral component, minus 2 mm for cartilage wear, and 1 mm for the kerf of the blade. Independent observers recorded the femoral resection thickness, operative times, PROMs, and alignment. For each femoral resection, the deviation between three groups of patients containing ten consecutive KA TKAs, was either insignificant (p = 0.695 to 1.000) or within the 0.5 mm resolution of the caliper, which indicated no learning curve. More than three groups were needed to determine the learning curve for the operative time; however, the IE surgeon's procedure dropped to 77 min for the last 10 patients, which was 20 min longer than the E surgeon. The resection deviations of the IE and E surgeon were comparable, except for the posterolateral femoral resection, which the IE surgeon under-resected by a mean of −0.8 mm (p < 0.0001). At a mean follow-up of 9 and 17 months, the Forgotten Joint Score, Oxford Knee Score, KOOS, and the alignment of the components and limbs were not different between the IE and E surgeon (p ≥ 0.6994). A surgeon that switches to unrestricted KA with manual instruments can determine their learning curve by computing the deviation of the distal and posterior femoral resections from the planned resection. Based on the present study, an IE surgeon could have resection accuracy, post-operative patient outcomes, and component alignment comparable to an E surgeon.
The skeleton is a preferred homing site for breast cancer metastasis. To date, treatment options for patients with bone metastases are mostly palliative and the disease is still incurable. Indeed, key mechanisms involved in breast cancer osteotropism are still only partially understood due to the lack of suitable animal models to mimic metastasis of human tumor cells to a human bone microenvironment. In the presented study, we investigate the use of a human tissue-engineered bone construct to develop a humanized xenograft model of breast cancer-induced bone metastasis in a murine host. Primary human osteoblastic cell-seeded melt electrospun scaffolds in combination with recombinant human bone morphogenetic protein 7 were implanted subcutaneously in non-obese diabetic/severe combined immunodeficient mice. The tissue-engineered constructs led to the formation of a morphologically intact 'organ' bone incorporating a high amount of mineralized tissue, live osteocytes and bone marrow spaces. The newly formed bone was largely humanized, as indicated by the incorporation of human bone cells and human-derived matrix proteins. After intracardiac injection, the dissemination of luciferase-expressing human breast cancer cell lines to the humanized bone ossicles was detected by bioluminescent imaging. Histological analysis revealed the presence of metastases with clear osteolysis in the newly formed bone. Thus, human tissue-engineered bone constructs can be applied efficiently as a target tissue for human breast cancer cells injected into the blood circulation and replicate the osteolytic phenotype associated with breast cancer-induced bone lesions. In conclusion, we have developed an appropriate model for investigation of species-specific mechanisms of human breast cancer-related bone metastasis in vivo.
Background: In total knee arthroplasty (TKA), inserts can have different levels of medial and lateral congruency determined by the acuteness of the upslopes of the anterior and posterior articular surfaces. The present study evaluated an insert with different levels of lateral congruency and a medial ball-in-socket congruency to test the hypothesis that a lateral flat (F) insert maximizes external tibial orientation at extension and internal orientation at 90° flexion and lowers the incidence of anterior lift-off relative to low-congruent (LC) and ultracongruent (UC) lateral inserts. Methods: Two surgeons treated 23 patients with unrestricted caliper-verified kinematic alignment (KA) and posterior cruciate ligament (PCL) retention. They randomly trialed inserts with a medial radial dial that functioned as a built-in goniometer by measuring the tibial orientation relative to a sagittal line on the femoral trial component. Anterior lift-off of the insert from the baseplate indicated PCL tightness. Results: The F insert’s mean of 9° of external tibial orientation was higher than that of the LC (5°, p < 0.0001) and UC inserts (2°, p < 0.0001). The −13° of internal tibial orientation at 90° flexion was higher than that of the LC (−9°, p < 0.0001) and UC inserts (−7°, p < 0.0001). The 0% incidence of anterior lift-off was less than that of the LC (26%) and UC inserts (57%) (p < 0.0001). Conclusions: Surgeons and implant manufacturers should know that adding congruency to the lateral articular surface limits external tibial orientation in extension and internal tibial orientation at 90° flexion and overtightens the PCL. These rotational limitations and flexion space tightness can adversely affect patellofemoral tracking and knee flexion.
Obwohl Simulatoruntersuchungen geringere Abriebwerte für Keramik-Köpfe gezeigt haben, konnten klinische Studien diese Erkenntnisse bisher nicht bestätigen. Bisher existiert keine Studie mit einer angemessenen Teststärke, die das Abriebverhalten von 28 mm CoCr- und Biolox-Köpfen vergleicht. Ziel dieser Studie war es, das in-vivo-Abriebverhalten von Keramik- und Metall-Köpfen in Verbindung mit der Harris-Galante-Pfanne zu untersuchen. Bei allen Patienten wurde ein zementfreies Pfannenimplantat nach Harris-Galante (Zimmer) implantiert. Die Inlays bestanden aus konventionell gefertigtem UHMWPE. 108 Patienten erhielten CoCr-Köpfe, 99 weitere Patienten wurden mit Keramik-Köpfen (Biolox) versorgt. Die 2D-Abriebrate wurde mit der Hip-analysis-suite von Martell über einen Zeitraum von 5,2 Jahren bei den Biolox- beziehungsweise 8 Jahren bei den CoCr-Köpfen untersucht. Die Metall-Köpfe zeigten einen linearen Abrieb von 0,14  0,11 mm pro Jahr, verglichen mit 0,13  0,08 mm pro Jahr bei den Keramik-Köpfen. Dieser Unterschied war, insbesondere nach Anpassung an die klinischen Einflussfaktoren, nicht signifikant (p = 0,46). Die Power-Analyse zeigte eine Teststärke von 80%, einen Unterschied von 28% (0,038 mm pro Jahr) zu detektieren. Die vorliegende Studie ist die erste, die das Abriebverhalten von 28 mm Metall- und Keramik-Köpfen im gleichen Pfannenimplantat mit ausreichender Teststärke vergleicht. Mit einer Teststärke von 80%, eine Abriebreduktion um 28% zu erkennen, zeigt diese Studie keinen Unterschied zwischen Biolox- und Metall-Köpfen in Verbindung mit konventionellen UHMWPE-Inlays in einer modularen Pfanne.
[Purpose] A wide variety of accelerometer tools are used to estimate human movement, but there are no adequate data relating to gait symmetry parameters in the context of knee osteoarthritis. This study's purpose was to evaluate a 3D-kinematic system using body-mounted sensors (gyroscopes and accelerometers) on the trunk and limbs. This is the first study to use spectral analysis for data post processing. [Subjects] Twelve patients with unilateral knee osteoarthritis (OA) (10 male) and seven age-matched controls (6 male) were studied. [Methods] Measurements with 3-D accelerometers and gyroscopes were compared to video analysis with marker positions tracked by a six-camera optoelectronic system (VICON 460, Oxford Metrics). Data were recorded using the 3D-kinematic system. [Results] The results of both gait analysis systems were significantly correlated. Five parameters were significantly different between the knee OA and control groups. To overcome time spent in expensive post-processing routines, spectral analysis was performed for fast differentiation between normal gait and pathological gait signals using the 3D-kinematic system. [Conclusions] The 3D-kinematic system is objective, inexpensive, accurate and portable, and allows long-term recordings in clinical, sport as well as ergonomic or functional capacity evaluation (FCE) settings. For fast post-processing, spectral analysis of the recorded data is recommended.
Background
For improved outcomes in total knee arthroplasty (TKA) correct implant fitting and positioning are crucial. In order to facilitate a best possible implant fitting and positioning patient-specific systems have been developed. However, whether or not these systems allow for better implant fitting and positioning has yet to be elucidated. For this reason, the aim was to analyse the novel patient-specific cruciate retaining knee replacement system iTotal (TM) CR G2 that utilizes custom-made implants and instruments for its ability to facilitate accurate implant fitting and positioning including correction of the hip-knee-ankle angle (HKA).
Methods
We assessed radiographic results of 106 patients who were treated with the second generation of a patient-specific cruciate retaining knee arthroplasty using iTotal\(^{TM}\) CR G2 (ConforMIS Inc.) for tricompartmental knee osteoarthritis (OA) using custom-made implants and instruments. The implant fit and positioning as well as the correction of the mechanical axis (hip-knee-ankle angle, HKA) and restoration of the joint line were determined using pre- and postoperative radiographic analyses.
Results
On average, HKA was corrected from 174.4 degrees +/- 4.6 degrees preoperatively to 178.8 degrees +/- 2.2 degrees postoperatively and the coronal femoro-tibial angle was adjusted on average 4.4 degrees. The measured preoperative tibial slope was 5.3 degrees +/- 2.2 degrees (mean +/- SD) and the average postoperative tibial slope was 4.7 degrees +/- 1.1 degrees on lateral views. The joint line was well preserved with an average modified Insall-Salvati index of 1.66 +/- 0.16 pre- and 1.67 +/- 0.16 postoperatively. The overall accuracy of fit of implant components was decent with a measured medial overhang of more than 1 mm (1.33 mm +/- 0.32 mm) in 4 cases only. Further, a lateral overhang of more than 1 mm (1.8 mm +/- 0.63) (measured in the anterior-posterior radiographs) was observed in 11 cases, with none of the 106 patients showing femoral notching.
Conclusion
The patient-specific iTotal\(^{TM}\) CR G2 total knee replacement system facilitated a proper fitting and positioning of the implant components. Moreover, a good restoration of the leg axis towards neutral alignment was achieved as planned. Nonetheless, further clinical follow-up studies are necessary to validate our findings and to determine the long-term impact of using this patient- specific system.
Background
Chronic osteomyelitis due to direct bone trauma or vascular insufficiency is a frequent problem in orthopaedic surgery. In contrast, acute haematogenous osteomyelitis represents a rare entity that almost exclusively affects prepubescent children or immunodeficient adults.
Case Presentation
In this article, we report the case of acute pneumococcal osteomyelitis of the humerus in an immunocompetent and otherwise healthy 44-year-old male patient presenting with minor inflammation signs and misleading clinical features.
Conclusions
The diagnosis had to be confirmed by open biopsy which allowed the initiation of a targeted therapy. A case of pneumococcal osteomyelitis of a long bone, lacking predisposing factors or trauma, is unique in adults and has not been reported previously.
The role of serum amyloid A (SAA) proteins, which are ligands for toll-like receptors, was analyzed in human bone marrow-derived mesenchymal stem cells (hMSCs) and their osteogenic offspring with a focus on senescence, differentiation andmineralization. In vitro aged hMSC developed a senescence-associated secretory phenotype (SASP), resulting in enhanced SAA1/2, TLR2/4 and proinflammatory cytokine (IL6, IL8, IL1\(\beta\), CXCL1, CXCL2) expression before entering replicative senescence. Recombinant human SAA1 (rhSAA1) induced SASP-related genes and proteins in MSC, which could be abolished by cotreatment with the TLR4-inhibitor CLI-095. The same pattern of SASP-resembling genes was stimulated upon induction of osteogenic differentiation, which is accompanied by autocrine SAA1/2 expression. In this context additional rhSAA1 enhanced the SASP-like phenotype, accelerated the proinflammatory phase of osteogenic differentiation and enhanced mineralization. Autocrine/paracrine and rhSAA1 via TLR4 stimulate a proinflammatory phenotype that is both part of the early phase of osteogenic differentiation and the development of senescence. This signaling cascade is tightly involved in bone formation and mineralization, but may also propagate pathological extraosseous calcification conditions such as calcifying inflammation and atherosclerosis.
Additive manufacturing of scaffolds with sub-micron filaments via melt electrospinning writing
(2015)
The aim of this study was to explore the lower resolution limits of an electrohydrodynamic process combined with direct writing technology of polymer melts. Termed melt electrospinning writing, filaments are deposited layer-by-layer to produce discrete three-dimensional scaffolds for in vitro research. Through optimization of the parameters (flow rate, spinneret diameter, voltage, collector distance) for poly-ϵ-caprolactone, we could direct-write coherent scaffolds with ultrafine filaments, the smallest being 817 ± 165 nm. These low diameter filaments were deposited to form box-structures with a periodicity of 100.6 ± 5.1 μm and a height of 80 μm (50 stacked filaments; 100 overlap at intersections). We also observed oriented crystalline regions within such ultrafine filaments after annealing at 55 °C. The scaffolds were printed upon NCO-sP(EO-stat-PO)-coated glass slide surfaces and withstood frequent liquid exchanges with negligible scaffold detachment for at least 10 days in vitro.
Der adenovirale SOX9-Gentransfer induziert nach 3-wöchiger in vitro Pelletkultur die chondrogene Differenzierung humaner mesenchymaler Stammzellen in Pelletkultur wirksamer als der TGFB1 Gentransfer mit geringerer Chondrozytenhypertrophie. Eine solche Technologie könnte zukünftig in vivo die Bildung von stabilerem hyalinem Knorpelregeneratgewebe ermöglichen.
Die Anzahl an implantierten Gelenkendoprothesen hat in den letzten Jahrzehnten stark zugenommen. Mit ihr auch die Anzahl an Protheseninfektionen. Die Haupterreger sind Staphylokokken (>80%). Diese sind in vivo unempfindlich gegenüber Antibiotika und somit ist die einzige sinnvolle Therapie der Ausbau der infizierten Prothese, welcher lange und kostenspielige Krankenhausaufenthalte für den Patienten mit sich bringt. Der Grund für diese Resistenz der Bakterien liegt darin, dass sie zur Biofilmbildung fähig sind und sehr gut an Fremdkörper-Oberflächen adhärieren können. Welche Methode nun geeignet ist, die Adhärenz von Staphylokokken am besten unter klinisch relevanten Bedingungen zu untersuchen, ist zu prüfen. Das in der Arbeit entwickelte Modell ermöglicht eine semiquantitative Bestimmung der Adhärenz. Für die Versuche wurden Metallprüfkörper aus Titan und Kobalt-Chrom-Legierung verwendet. Zuvor wurden diese Metalle mit bestimmen Reinigungs- und Sterilisationsvorgängen gesäubert. Ein Teil der verwendeten Prüfkörper ist vor Beimpfung mit den Keimen durch Serumproteine bzw. Gewebsflüssigkeiten beschichtet worden, um das Anheftungsverhalten unter verschiedenen Bedingungen beurteilen zu können. Hierfür wurden Albumin, Kollagen Typ I und Typ II, Fibronektin und Fibrinogen verwendet. Sieben Titan-Prüfkörper sind in Schlieren (Schweiz) durch ein spezielles Verfahren mit PLL-g-PEG, einem Makromolekül welches die Adhäsion von Proteinen herabsetzt, beschichtet worden. Eine Auswirkung durch Infektionen sollte hierbei überprüft werden. Die Auswertung wurde unter REM-Betrachtung durchgeführt. Hierbei ist eine semiquantitative Abstufung der Adhärenzkraft von 1-5 getroffen worden. In den Ergebnissen zeigten die beiden verwendeten Metalle Titan und Kobalt-Chrom-Legierung keine wesentlichen Unterschiede in der gezeigten Adhärenz von Staphylokokken. Durch die Serumprotein- und Gewebsflüssigkeitsbeschichtung ließen sich Unterschiede unter verschiedenen Bedingungen feststellen. Fibronektin und Fibrinogen bewirken eine starke Zunahme an adhärenten Bakterienzellen. Kollagen Typ I und II zeigen eine leichte Adhärenzverstärkung und bewirken Biofilmbildung. Albuminbeschichtung reduziert die Anzahl adhärenter Staphylokokken. Die PLL-g-PEG Beschichtung löst starke Adhärenz und Biofilmbildung aus. Die hier angewandte Methode, kontaminierte Metallprüfkörper unter dem Rasterelektronenmikroskop zu betrachten, eignet sich um das Adhärenzverhalten von Bakterien zu beurteilen. Dabei lassen sich die Versuchsbedingungen auf vielfache Weise verändern. Verschiedene Metalle und andere Materialien können miteinander verglichen werden. Des Weiteren ist es möglich, unterschiedliche Proteinbeschichtungen vorzunehmen, um deren Einfluss auf die Adhärenz zu zeigen. Zusätzlich ist eine Durchführung der Versuche unter Bewegung möglich, was eine Annäherung an die Verhältnisse im menschlichen Körper bedeutet. Neben Staphylokokken könnten auch andere Bakterienspezies untersucht werden. In dieser Studie wird erstmals gezeigt, dass Kollagen eine Biofilmbildung bei Staphylokokken induziert. Dies bedarf weiterer Untersuchung, welcher Mechanismus hierfür verantwortlich ist. Die PLL-g-PEG Beschichtung hat auf Infektionen keine erfolgsversprechende Wirkung. Im Gegenteil, es kommt zu einer starken Besiedlung des Fremdmaterials. Albumin dagegen zeichnet sich durch eine Herabsetzung der Adhärenzstärke aus. Daraus könnte man therapeutischen Nutzen ziehen und Implantate vor Einbau mit Albumin beschichten.
Adjuvant Radiotherapy
(2011)
Adult stem cells in aging
(2022)
Die Möglichkeiten der operativen Rekonstruktion degenerativ veränderter Hüftgelenke sind komplex und vielfältig. Bei den derzeit zur Verfügung stehenden operativen Behandlungsmassnahmen führen die Vor- und Nachteile immer wieder zur Diskussionen und Abwägung der Operationsverfahren. Hierbei stehen sich die rasche postoperative Mobilisierung sowie eine verminderte Rekonvaleszenzzeit mit den diskutierten Nachteilen einer schlechteren Übersichtlichkeit und damit verbundenen Fehlimplantationen gegenüber. Dies und die damit verbundene volkswirtschaftliche Bedeutung sind ein ständiger Ausgangspunkt für das Bemühen den optimalen Zugangsweg zu etablieren. Daher stellte das von Smith-Peterson 1949 publizierte Verfahren einen Meilenstein in der operativen Therapie dar. Hierdurch konnten zum einen die operationstechnischen Vorteile wie auch das volkswirtschaftliche Begehren nach kürzeren postoperativen Verweildauern vereint werden. Die Modifizierung dieses Zugangsweges hat sich bereits in einer großen Anzahl prospektiver Studien als zuverlässiges Rekonstruktionsverfahren etabliert und erfüllt zudem auch die Anforderungen der heutigen Medizin nach ästhetisch schönen Ergebnissen. In der vorliegenden Arbeit wurde eine prospektive Fallstudie des direkten anterioren Zugangs mit einem gesunden Vergleichskollektiv durchgeführt. Mit dem Ziel, die Aktivität ein Jahr postoperativ nach Implantation einer HTEP mit gesunden Probanden zu vergleichen. Von Januar 2009 bis Mai 2011 wurden insgesamt 77 Patienten und 59 Probanden in die Studie aufgenommen. Als Vergleichswerte wurde zum einen die klinische wie auch die radiologische Untersuchung herangezogen. In der klinischen Untersuchung zeigte sich insgesamt ein signifikanter Anstieg der untersuchten Scores im Vergleich mit den präoperativen Ergebnissen bei den Operierten. Im Vergleich zu den Probanden erzielen die Patienten ein Jahr nach HTEP teilweise noch schlechtere Werte in dem Bewegungsumfang und den Aktivitätsniveaus welche mittels der Auswertung des Stepwatches, des TWB und des Arzt-Patienten-Fragebogens erhoben wurden. Die radiologische Bewertung diente zur Feststellung der Positionierung der HTEP. Mit guten Positionierungen durch den direkten anterioren Zugang. Die Bewertung der Funktionalität zwischen den beiden Gruppen erfolgte durch den HHS, XSFMA- D und den Arzt-Patientenfragenbogen. Hierbei konnten ähnliche Ergebnisse, wie bereits oben beschrieben, verzeichnet werden mit guten Werten in der Gruppe der untersuchten Patienten, jedoch einer geringeren Funktionalität im Vergleich zu den Probanden. Die vorliegende Arbeit zeigt, dass der direkte anteriore Zugang die Wiederherstellung eines guten postoperativen Gesundheitszustandes mit erreichen eines hohen postoperativen Aktivitätslevels der Patienten ermöglicht. Ebenso erfüllt dieser Zugangsweg die Anforderungen der heutigen Medizin im Sinne einer schnellen postoperativen Mobilisation. Im Vergleich zu anderen minimal-invasiven Verfahren zeigen sich eine gute Implantierbarkeit, eine gute Positionierung und ein niedriges Komplikationsniveau. Prinzipiell hat der minimal-invasive anteriore Zugang das Potenzial sich als ein Standardverfahren in der operativen Rekonstruktion bei Hüftgelenksersatz zu etablieren, jedoch wäre ein direkter Vergleich mit dem lateralen Zugang erstrebenswert und sollte in weiteren Studien verglichen werden.