• Treffer 5 von 5
Zurück zur Trefferliste

Development and validation of a sensitive liquid chromatography tandem mass spectrometry assay for the simultaneous determination of ten kinase inhibitors in human serum and plasma

Zitieren Sie bitte immer diese URN: urn:nbn:de:bvb:20-opus-231925
  • A liquid chromatography tandem mass spectrometry method for the analysis of ten kinase inhibitors (afatinib, axitinib, bosutinib,cabozantinib, dabrafenib, lenvatinib, nilotinib, osimertinib, ruxolitinib, and trametinib) in human serum and plasma for theapplication in daily clinical routine has been developed and validated according to the US Food and Drug Administration andEuropean Medicines Agency validation guidelines for bioanalytical methods. After protein precipitation of plasma samples withacetonitrile, chromatographic separation wasA liquid chromatography tandem mass spectrometry method for the analysis of ten kinase inhibitors (afatinib, axitinib, bosutinib,cabozantinib, dabrafenib, lenvatinib, nilotinib, osimertinib, ruxolitinib, and trametinib) in human serum and plasma for theapplication in daily clinical routine has been developed and validated according to the US Food and Drug Administration andEuropean Medicines Agency validation guidelines for bioanalytical methods. After protein precipitation of plasma samples withacetonitrile, chromatographic separation was performed at ambient temperature using a Waters XBridge® Phenyl 3.5μm(2.1×50 mm) column. The mobile phases consisted of water-methanol (9:1, v/v) with 10 mM ammonium bicarbonate as phase A andmethanol-water (9:1, v/v) with 10 mM ammonium bicarbonate as phase B. Gradient elution was applied at a flow rate of 400μL/min. Analytes were detected and quantified using multiple reaction monitoring in electrospray ionization positive mode. Stableisotopically labeled compounds of each kinase inhibitor were used as internal standards. The acquisition time was 7.0 min perrun. All analytes and internal standards eluted within 3.0 min. The calibration curves were linear over the range of 2–500 ng/mLfor afatinib, axitinib, bosutinib, lenvatinib, ruxolitinib, and trametinib, and 6–1500 ng/mL for cabozantinib, dabrafenib, nilotinib,and osimertinib (coefficients of correlation≥0.99). Validation assays for accuracy and precision, matrix effect, recovery,carryover, and stability were appropriate according to regulatory agencies. The rapid and sensitive assay ensures high throughputand was successfully applied to monitor concentrations of kinase inhibitors in patients.zeige mehrzeige weniger

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Autor(en): Fatemeh Aghai, Sebastian Zimmermann, Max Kurlbaum, Pius Jung, Theo Pelzer, Hartwig Klinker, Nora Isberner, Oliver Scherf-ClavelORCiD
URN:urn:nbn:de:bvb:20-opus-231925
Dokumentart:Artikel / Aufsatz in einer Zeitschrift
Institute der Universität:Medizinische Fakultät / Medizinische Klinik und Poliklinik I
Medizinische Fakultät / Medizinische Klinik und Poliklinik II
Fakultät für Chemie und Pharmazie / Institut für Pharmazie und Lebensmittelchemie
Sprache der Veröffentlichung:Englisch
Titel des übergeordneten Werkes / der Zeitschrift (Englisch):Analytical and Bioanalytical Chemistry
ISSN:1618-2642
Erscheinungsjahr:2021
Band / Jahrgang:413
Seitenangabe:599–612
Originalveröffentlichung / Quelle:Analytical and Bioanalytical Chemistry (2021) 413:599–612. https://doi.org/10.1007/s00216-020-03031-7
DOI:https://doi.org/10.1007/s00216-020-03031-7
Allgemeine fachliche Zuordnung (DDC-Klassifikation):5 Naturwissenschaften und Mathematik / 54 Chemie / 540 Chemie und zugeordnete Wissenschaften
6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Freie Schlagwort(e):afatinib; kinase inhibitors; liquid chromatography tandem mass spectrometry (LC-MS/MS; osimertinib; therapeutic drug monitoring
Datum der Freischaltung:18.05.2021
Lizenz (Deutsch):License LogoCC BY: Creative-Commons-Lizenz: Namensnennung 4.0 International